Linear response range characterization and in vivo application of laser speckle imaging of blood flow dynamics

被引:75
作者
Choi, Bernard
Ramirez-San-Juan, Julio C.
Lotfi, Justin
Nelson, J. Stuart
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Med Clin, Irvine, CA 92612 USA
[3] Univ Calif Irvine, Sch Biol Sci, Irvine, CA 92612 USA
[4] Inst Nacl Astrofis Opt & Elect, Puebla, Mexico
关键词
laser Doppler flowmetry; window chamber; microvasculature; Doppler optical coherence tomography;
D O I
10.1117/1.2341196
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Noninvasive blood flow imaging can provide critical information on the state of biological tissue and the efficacy of approaches to treat disease. With laser speckle imaging (LSI), relative changes in blood flow are typically reported, with the assumption that the measured values are on a linear scale. A linear relationship between the measured and actual flow rate values has been suggested. The actual flow rate range, over which this linear relationship is valid, is unknown. Herein we report the linear response range and velocity dynamic range (VDR) of our LSI instrument at two relevant camera integration times. For integration times of 1 and 10 ms, the best case VDR was 80 and 60 dB, respectively, and the worst case VDR was 20 and 50 dB. The best case VDR values were similar to those reported in the literature for optical Doppler tomography. We also demonstrate the potential of LSI for monitoring blood flow dynamics in the rodent dorsal skinfold chamber model. These findings imply that LSI can provide accurate wide-field maps of microvascular blood flow rate dynamics and highlight heterogeneities in flow response to the application of exogenous agents. (c) 2006 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:7
相关论文
共 40 条
  • [1] Selective photothermolysis of blood vessels following flashlamp-pumped pulsed dye laser irradiation:: In vivo results and mathematical modelling are in agreement
    Babilas, P
    Shafirstein, G
    Bäumler, W
    Baier, J
    Landthaler, M
    Szeimies, RM
    Abels, C
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2005, 125 (02) : 343 - 352
  • [2] Flow measurement without phase information in optical coherence tomography images
    Barton, JK
    Stromski, S
    [J]. OPTICS EXPRESS, 2005, 13 (14) : 5234 - 5239
  • [3] Investigating pulsed dye laser-blood vessel interaction with color Doppler optical coherence tomography
    Barton, JK
    Welch, AJ
    Izatt, JA
    [J]. OPTICS EXPRESS, 1998, 3 (06): : 251 - 256
  • [4] Local hyperhemia to heating is impaired in secondary Raynaud's phenomenon
    Boignard, A
    Salvat-Melis, M
    Carpentier, PH
    Minson, CT
    Grange, L
    Duc, C
    Sarrot-Reynauld, F
    Cracowski, JL
    [J]. ARTHRITIS RESEARCH & THERAPY, 2005, 7 (05) : R1103 - R1112
  • [5] Laser Doppler and time-varying speckle: A reconciliation
    Briers, JD
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1996, 13 (02) : 345 - 350
  • [6] Capillary blood flow monitoring using laser speckle contrast analysis (LASCA)
    Briers, JD
    Richards, G
    He, XW
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) : 164 - 175
  • [7] Alginate plasma expander maintains perfusion and plasma viscosity during extreme hemodilution
    Cabrales, P
    Tsai, AG
    Intaglietta, M
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2005, 288 (04): : H1708 - H1716
  • [8] Chen Q, 2004, MOL CANCER THER, V3, P1311
  • [9] Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media
    Chen, ZP
    Milner, TE
    Dave, D
    Nelson, JS
    [J]. OPTICS LETTERS, 1997, 22 (01) : 64 - 66
  • [10] Hyperosmotic chemical agent's effect on in vivo cerebral blood flow revealed by laser speckle
    Cheng, HY
    Luo, QM
    Zeng, SQ
    Chen, SB
    Luo, WH
    Gong, H
    [J]. APPLIED OPTICS, 2004, 43 (31) : 5772 - 5777