Fast B1 Mapping Based on Double-Angle Method with T1 Correction Using Standard Pulse Sequence

被引:3
作者
Ishimori, Yoshiyuki [1 ]
Shimanuki, Takeshi [2 ]
Kobayashi, Tomoya [1 ]
Monma, Masahiko [1 ]
机构
[1] Ibaraki Prefectural Univ Hlth Sci, Dept Radiol Sci, Kashiwa, Chiba, Japan
[2] Jikei Univ, Kashiwa Hosp, Dept Radiol, Kashiwa, Chiba, Japan
关键词
B1; map; double-angle method; flip angle; radio frequency; T1; correction; POWER DEPOSITION; MRI; SENSITIVITY; ACCURACY;
D O I
10.4103/jmp.jmp_78_21
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiofrequency (RF) field (B1) mapping by combining the double-angle method (DAM) and T1 correction was investigated. The signal intensities S1 and S2 acquired by flip angle (FA) alpha and double FA 2 alpha at short repetition time (TR) were converted to a signal intensity at TR=infinity by T1 correction. Then, these were used for DAM calculation. The T1 values are measured from two different images acquired with different TRs based on the saturation recovery (SR) method preliminarily. The effects of imaging parameters for T1 estimation and measured FA were investigated using CuSO4-doped water phantoms. A two-dimensional gradient echo type echo planar imaging pulse sequence was used. T1 values obtained by the 2-SR method were underestimated compared to the multipoint inversion recovery method. FA error was less than 5% when the appropriate imaging parameters were used. The acquisition time could be shortened to under 25 s by the use of T1-corrected DAM.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 38 条
[1]   Ultra-High-Field MR Neuroimaging [J].
Balchandani, P. ;
Naidich, T. P. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (07) :1204-1215
[2]   Mapping of low flip angles in magnetic resonance [J].
Balezeau, Fabien ;
Eliat, Pierre-Antoine ;
Cayamo, Alejandro Bordelois ;
Saint-Jalmes, Herve .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20) :6635-6647
[3]   Radiofrequency transmit calibration: A multi-center evaluation of vendor-provided radiofrequency transmit mapping methods [J].
Bliesener, Yannick ;
Zhong, Xinran ;
Guo, Yi ;
Boss, Michael ;
Bosca, Ryan ;
Laue, Hendrik ;
Chung, Caroline ;
Sung, Kyunghyun ;
Nayak, Krishna S. .
MEDICAL PHYSICS, 2019, 46 (06) :2629-2637
[4]   B1 Mapping for Bias-Correction in Quantitative T1 Imaging of the Brain at 3T Using Standard Pulse Sequences [J].
Boudreau, Mathieu ;
Tardif, Christine L. ;
Stikov, Nikola ;
Sled, John G. ;
Lee, Wayne ;
Pike, G. Bruce .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) :1673-1682
[5]   Steady-state double-angle method for rapid B1 mapping [J].
Bouhrara, Mustapha ;
Spencer, Richard G. .
MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) :189-201
[6]   Radiofrequency power deposition utilizing thermal imaging [J].
Cline, H ;
Mallozzi, R ;
Li, Z ;
McKinnon, G ;
Barber, W .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (06) :1129-1137
[7]   Saturated double-angle method for rapid B1 plus mapping [J].
Cunningham, Charles H. ;
Pauly, John M. ;
Nayak, Krishna S. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1326-1333
[8]  
Deichmann R, 1999, MAGNET RESON MED, V42, P206, DOI 10.1002/(SICI)1522-2594(199907)42:1<206::AID-MRM28>3.0.CO
[9]  
2-Q
[10]   Fast, accurate, and precise mapping of the RF field in vivo using the 180° signal null [J].
Dowell, Nicholas G. ;
Tofts, Paul S. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) :622-630