Angiographic patency after robotic beating heart totally endoscopic coronary artery bypass grafting facilitated by automated distal anastomotic connectors

被引:7
作者
Balkhy, Husam H. [1 ]
Nathan, Sandeep [2 ]
Torregrossa, Gianluca [1 ]
Kitahara, Hiroto [1 ]
Nisivaco, Sarah [1 ]
McCrorey, Mackenzie [1 ]
Patel, Brooke [1 ]
机构
[1] Univ Chicago Med, Dept Cardiothorac Surg, Sect Cardiothorac Surg, Chicago, IL 60637 USA
[2] Univ Chicago Med, Dept Med, Div Cardiol, Chicago, IL 60637 USA
关键词
Coronary artery bypass grafting; Totally endoscopic coronary artery bypass; Minimally invasive coronary surgery; Distal anastomotic connector; FOLLOW-UP; DEVICE; FAILURE; REVASCULARIZATION; PREDICTORS; EXPERIENCE; SURVIVAL; INSIGHTS; OUTCOMES; SURGERY;
D O I
10.1093/icvts/ivaa149
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Robotic totally endoscopic coronary artery bypass (TECAB) on the beating heart has been facilitated in our experience using distal coronary anastomotic connectors. In this study, we retrospectively reviewed graft patency in all robotic TECAB patients who underwent formal angiography at our current institution over a 5-year period. METHODS: Between July 2013 and June 2018, 361 consecutive patients underwent robotic beating-heart TECAB. Of these patients, 121 had a follow-up angiogram, which assessed graft patency. Eighty-four patients had an angiogram as part of planned hybrid procedures and 37 patients underwent an unplanned angiogram for clinical indications. Retrospective analysis of angiographic patency and clinical outcomes was performed. RESULTS: The mean Society of Thoracic Surgeons predicted risk of mortality was 1.8%. Single-vessel bypass was performed in 40 (33%) patients and multivessel grafting in 81 (67%). Average flow (ml/min) and pulsatility index in the grafts was 74.7 +/- 39.1 and 1.42 +/- 0.52, respectively. The number of grafts evaluated was 204 (130 left internal mammary artery and 74 right internal mammary artery grafts). The median time to angiography was 1.0 and 16.0 months and graft patency was 98% and 91% in the hybrid and non-hybrid groups, respectively. Overall graft patency was 95.6% (left internal mammary artery = 96%; right internal mammary artery = 93%). Left internal mammary artery to left anterior descending artery graft patency was 97%. Clinical follow-up was available for 316 (88%) patients at mean 22.5 +/- 15.1 months. Freedom from major adverse cardiac events at 2 years was 92%. CONCLUSIONS: In this consecutive series of patients undergoing formal angiography after robotic single and multivessel TECAB, we found satisfactory graft patency and 2-year clinical outcomes. Longer-term follow-up is warranted.
引用
收藏
页码:467 / 474
页数:8
相关论文
共 25 条
[1]   Results of the prospective multicenter trial of robotically assisted totally endoscopic coronary artery bypass grafting [J].
Argenziano, M ;
Katz, M ;
Bonatti, J ;
Srivastava, S ;
Murphy, D ;
Poirier, R ;
Loulmet, D ;
Siwek, L ;
Kreaden, U ;
Ligon, D .
ANNALS OF THORACIC SURGERY, 2006, 81 (05) :1666-1675
[2]   Residual SYNTAX Score After Advanced Hybrid Robotic Totally Endoscopic Coronary Revascularization [J].
Balkhy, Husam H. ;
Kitahara, Hiroto ;
Hirai, Taishi ;
Matsukage, Hitoshi ;
Nathan, Sandeep .
ANNALS OF THORACIC SURGERY, 2020, 109 (06) :1826-1832
[3]   Multicenter Assessment of Grafts in Coronaries Midterm Evaluation of the C-Port Device (the MAGIC Study) [J].
Balkhy, Husam H. ;
Patel, Nirav C. ;
Ramshandani, Mahesh ;
Kitahara, Hiroto ;
Subramanian, Valavunar A. ;
Augelli, Nicholas V. ;
Tobler, Gareth ;
Cai, Tung H. .
INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2018, 13 (04) :273-281
[4]   The C-Port Distal Coronary Anastomotic Device Is Comparable With a Hand-Sewn Anastomosis Human Histological Case Study [J].
Balkhy, Husam H. ;
Nisivaco, Sarah M. ;
Husain, Aliya N. ;
Jeevanandam, Valluvan ;
Arif, Quidsia .
INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2018, 13 (02) :140-143
[5]  
Balkhy HH, 2017, INNOVATIONS, V12, P9, DOI 10.1177/155698451701200103
[6]  
Balkhy HH, 2010, INNOVATIONS, V5, P109, DOI 10.1097/IMI.0b013e3181d714ba
[7]   Integrating Coronary Anastomotic Connectors and Robotics Toward a Totally Endoscopic Beating Heart Approach: Review of 120 Cases [J].
Balkhy, Husam H. ;
Wann, L. Samuel ;
Krienbring, Dorothy ;
Arnsdorf, Susan E. .
ANNALS OF THORACIC SURGERY, 2011, 92 (03) :821-828
[8]   Five Hundred Cases of Robotic Totally Endoscopic Coronary Artery Bypass Grafting: Predictors of Success and Safety [J].
Bonaros, Nikolaos ;
Schachner, Thomas ;
Lehr, Eric ;
Kofler, Markus ;
Wiedemann, Dominik ;
Hong, Patricia ;
Wehman, Brody ;
Zimrin, David ;
Vesely, Mark K. ;
Friedrich, Guy ;
Bonatti, Johannes .
ANNALS OF THORACIC SURGERY, 2013, 95 (03) :803-812
[9]  
Bonatti J, 2012, INNOVATIONS, V7, P3, DOI 10.1097/IMI.0b013e3182552ea8
[10]  
Cai TH, 2007, INNOVATIONS, V2, P245, DOI 10.1097/IMI.0b013e31815cd976