A long lifetime chemical sensor: study on fluorescence property of fluorescein isothiocyanate and preparation of pH chemical sensor

被引:51
作者
Ma, LY
Wang, HY [1 ]
Xie, H
Xu, LX
机构
[1] Shandong Normal Univ, Coll Chem Chem Engn & Mat Sci, Jinan 250014, Peoples R China
[2] Binzhou Med Coll, Dept Chem, Binzhou 256603, Peoples R China
[3] Shandong Jiaotong Univ, Jinan 250023, Peoples R China
关键词
fluorescein isothiocyanate; chemical sensor; fluorimetry;
D O I
10.1016/j.saa.2003.10.004
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The fluorescence property of fluorescein isothiocyanate (FITC) in acid-alkaline medium was studied by spectrofluorimetry. The characteristic of FITC response to hydrogen ion has been examined in acid-alkaline solution. A novel pit chemical sensor was prepared based on the relationship between the relative fluorescence intensity of FITC and pH. The measurement of relative fluorescence intensity was carried out at 362 nm with excitation at 250 nm. The excellent linear relationship was obtained between relative fluorescence intensity and pH in the range of pH 1-5. The linear regression equation of the calibration graph is F = 66.871 + 6.605 pH (F is relative fluorescence intensity), with a correlation coefficient of linear regression of 0.9995. Effects of temperature, concentration of FITC on the response to hydrogen ion had been examined. It was important that this chemical sensor was long lifetime, and the property of response to hydrogen ion was stable for at least 70 days. This pH sensor can be used for measuring pH value in water solution. The accuracy is 0.01 pH unit. The results obtained by the pH sensor agreed with those by the pH meter. Obviously, this pH sensor is potential for determining pH change real time in biological system. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1865 / 1872
页数:8
相关论文
共 34 条
[1]   Drug-selective electrode for ketamine determination in pharmaceutical preparations and electrochemical study of drug with BSA [J].
Alizadeh, N ;
Mehdipour, R .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) :725-731
[2]   Impedance spectroscopy on pH-sensors with lithium lanthanum titanate sensitive material [J].
Bohnke, C ;
Fourquet, JL .
ELECTROCHIMICA ACTA, 2003, 48 (13) :1869-1878
[3]   Disposable tyrosinase-peroxidase bi-enzyme sensor for amperometric detection of phenols [J].
Chang, SC ;
Rawson, K ;
McNeil, CJ .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1015-1023
[5]   Fluorescence emission studies of an azlactone derivative embedded in polymer films -: An optical sensor for pH measurements [J].
Ertekin, K ;
Alp, S ;
Karapire, C ;
Yenigül, B ;
Henden, E ;
Içli, S .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2000, 137 (2-3) :155-161
[6]   Novel monohydrogenphosphate sensor based on vanadyl salophen [J].
Ganjali, MR ;
Mizani, F ;
Salavati-Niasari, M .
ANALYTICA CHIMICA ACTA, 2003, 481 (01) :85-90
[7]   Preparation of ethambutol-copper(II) complex and fabrication of PVC based membrane potentiometric sensor for copper [J].
Gupta, VK ;
Prasad, R ;
Kumar, A .
TALANTA, 2003, 60 (01) :149-160
[8]   Methylene blue potentiometric sensor for selective determination of sulfide ions [J].
Hassan, SSM ;
Marzouk, SAM ;
Sayour, HEM .
ANALYTICA CHIMICA ACTA, 2002, 466 (01) :47-55
[9]   A novel tetrachlorothallate (III)-PVC membrane sensor for the potentiometric determination of thallium (III) [J].
Hassanien, MM ;
Abou-El-Sherbini, KS ;
Mostafa, GAE .
TALANTA, 2003, 59 (02) :383-392
[10]   Lateral diffusion and conductance properties of a fluorescein-labelled alamethicin in planar lipid bilayers [J].
Helluin, O ;
Dugast, JY ;
Molle, G ;
Mackie, AR ;
Ladha, S ;
Duclohier, H .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1997, 1330 (02) :284-292