Design and Control of an Magnetic Resonance Compatible Precision Pneumatic Active Cannula Robot

被引:31
作者
Comber, David B. [1 ]
Barth, Eric J. [1 ]
Webster, Robert J. [1 ]
机构
[1] Vanderbilt Univ, Dept Mech Engn, Nashville, TN 37235 USA
来源
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME | 2014年 / 8卷 / 01期
基金
美国国家科学基金会;
关键词
MR-compatible robot; active cannula; pneumatic piston-cylinder control; LASER-ABLATION; INTERVENTIONS; SYSTEM;
D O I
10.1115/1.4024832
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The versatile uses and excellent soft tissue distinction afforded by magnetic resonance imaging (MRI) has led to the development of many MR-compatible devices for MRI-guided interventions. This paper presents a fully pneumatic MR-compatible robotic platform designed for neurosurgical interventions. Actuated by nonmagnetic pneumatic piston-cylinders, the robotic platform manipulates a five degree-of-freedom active cannula designed for deep brain interventions. Long lines of tubing connect the cylinders to remotely located pressure sensors and valves, and MRI-compatible optical sensors mounted on the robot provide the robot joint positions. A robust, nonlinear, model-based controller precisely translates and rotates the robot joints, with mean steady-state errors of 0.032mm and 0.447 deg, respectively. MRI-compatibility testing in a 3-Tesla closed-bore scanner has shown that the robot has no impact on the signal-to-noise ratio, and that geometric distortion remains within recommended calibration limits for the scanner. These results demonstrate that pneumatic actuation is a promising solution for neurosurgical interventions that either require or can benefit from submillimeter precision. Additionally, this paper provides a detailed solution to the control problems imposed by severe nonlinearities in the pneumatic system, which has not previously been discussed in the context of MR-compatible devices.
引用
收藏
页数:7
相关论文
共 30 条
[11]   Design and Control of Concentric-Tube Robots [J].
Dupont, Pierre E. ;
Lock, Jesse ;
Itkowitz, Brandon ;
Butler, Evan .
IEEE TRANSACTIONS ON ROBOTICS, 2010, 26 (02) :209-225
[12]   MRI-compatible pneumatic robot for transperineal prostate needle placement [J].
Fischer, Gregory S. ;
Iordachita, Iulian ;
Csoma, Csaba ;
Tokuda, Junichi ;
DiMaio, Simon P. ;
Tempany, Clare M. ;
Hata, Nobuhiko ;
Fichtinger, Gabor .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2008, 13 (03) :295-305
[13]   Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast [J].
Larson, BT ;
Erdman, AG ;
Tsekos, NV ;
Yacoub, E ;
Tsekos, PV ;
Koutlas, LG .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (04) :458-465
[14]   A prospective study of the requirement for and the provision of epilepsy surgery in the United Kingdom [J].
Lhatoo, SD ;
Solomon, JK ;
McEvoy, AW ;
Kitchen, ND ;
Shorvon, SD ;
Sander, JW .
EPILEPSIA, 2003, 44 (05) :673-676
[15]  
Macura Katarzyna J, 2008, Top Magn Reson Imaging, V19, P297, DOI 10.1097/RMR.0b013e3181aa68b8
[16]  
Masamune K, 1995, J Image Guid Surg, V1, P242, DOI 10.1002/(SICI)1522-712X(1995)1:4<242::AID-IGS7>3.3.CO
[17]  
2-R
[18]   INNOMOTION for percutaneous image-guided interventions [J].
Melzer, Andreas ;
Gutmann, Bernd ;
Remmele, Thomas ;
Wolf, Renate ;
Lukoscheck, Andreas ;
Bock, Michael ;
Bardenheuer, Hubert ;
Fischer, Harald .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2008, 27 (03) :66-73
[19]   Advancing neurosurgery with image-guided robotics Technical note [J].
Pandya, Shawna ;
Motkoski, Jason W. ;
Serrano-Almeida, Cesar ;
Greer, Alexander D. ;
Latour, Isabelle ;
Sutherland, Garnette R. .
JOURNAL OF NEUROSURGERY, 2009, 111 (06) :1141-1149
[20]   A manipulator system for 14-gauge large core breast biopsies inside a high-field whole-body MR scanner [J].
Pfleiderer, SOR ;
Reichenbach, JR ;
Azhari, T ;
Marx, C ;
Malich, A ;
Schneider, A ;
Vagner, J ;
Fischer, H ;
Kaiser, WA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (04) :493-498