Design and Control of an Magnetic Resonance Compatible Precision Pneumatic Active Cannula Robot

被引:31
作者
Comber, David B. [1 ]
Barth, Eric J. [1 ]
Webster, Robert J. [1 ]
机构
[1] Vanderbilt Univ, Dept Mech Engn, Nashville, TN 37235 USA
来源
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME | 2014年 / 8卷 / 01期
基金
美国国家科学基金会;
关键词
MR-compatible robot; active cannula; pneumatic piston-cylinder control; LASER-ABLATION; INTERVENTIONS; SYSTEM;
D O I
10.1115/1.4024832
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The versatile uses and excellent soft tissue distinction afforded by magnetic resonance imaging (MRI) has led to the development of many MR-compatible devices for MRI-guided interventions. This paper presents a fully pneumatic MR-compatible robotic platform designed for neurosurgical interventions. Actuated by nonmagnetic pneumatic piston-cylinders, the robotic platform manipulates a five degree-of-freedom active cannula designed for deep brain interventions. Long lines of tubing connect the cylinders to remotely located pressure sensors and valves, and MRI-compatible optical sensors mounted on the robot provide the robot joint positions. A robust, nonlinear, model-based controller precisely translates and rotates the robot joints, with mean steady-state errors of 0.032mm and 0.447 deg, respectively. MRI-compatibility testing in a 3-Tesla closed-bore scanner has shown that the robot has no impact on the signal-to-noise ratio, and that geometric distortion remains within recommended calibration limits for the scanner. These results demonstrate that pneumatic actuation is a promising solution for neurosurgical interventions that either require or can benefit from submillimeter precision. Additionally, this paper provides a detailed solution to the control problems imposed by severe nonlinearities in the pneumatic system, which has not previously been discussed in the context of MR-compatible devices.
引用
收藏
页数:7
相关论文
共 30 条
[1]  
[Anonymous], ADV ROBOTICS VIRTUAL
[2]   PREOPERATIVE MRI PREDICTS OUTCOME OF TEMPORAL LOBECTOMY - AN ACTUARIAL ANALYSIS [J].
BERKOVIC, SF ;
MCINTOSH, AM ;
KALNINS, RM ;
JACKSON, GD ;
FABINYI, GCA ;
BRAZENOR, GA ;
BLADIN, PF ;
HOPPER, JL .
NEUROLOGY, 1995, 45 (07) :1358-1363
[3]  
Bo Yang, 2011, IEEE International Conference on Robotics and Automation, P674
[4]   Experimental comparison of position tracking control algorithms for pneumatic cylinder actuators [J].
Bone, Gary M. ;
Ning, Shu .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2007, 12 (05) :557-561
[5]  
Carpentier A, 2008, NEUROSURGERY, V63, P21, DOI [10.1227/01.NEU.0000311254.63848.72, 10.1227/01.neu.0000335007.07381.df]
[6]  
Chillari S, 2001, IEEE DECIS CONTR P, P1168, DOI 10.1109/CDC.2001.981043
[7]  
Comber D., 2011, P DYN SYST CONTR C B, P45
[8]  
Comber D.B., 2012, ASME J MED DEV, V6
[9]  
Comber D.B., 2012, Proceedings of the Fluid Power and Motion Control Symposium, P283
[10]   MR-guided stereotactic laser ablation of epileptogenic foci in children [J].
Curry, Daniel J. ;
Gowda, Ashok ;
McNichols, Roger J. ;
Wilfong, Angus A. .
EPILEPSY & BEHAVIOR, 2012, 24 (04) :408-414