Microendoscopy for hypericin fluorescence tumor diagnosis in a subcutaneous glioma mouse model

被引:9
作者
Noell, Susan [1 ]
Feigl, Guenther C. [1 ,2 ]
Serifi, Dzenan [1 ]
Mayer, Daniel [1 ]
Naumann, Ulrike [3 ,4 ]
Goebel, Werner [5 ]
Ehrhardt, Andre [5 ]
Ritz, Rainer [1 ,6 ]
机构
[1] Univ Tubingen, Dept Neurosurg, D-72076 Tubingen, Germany
[2] Katharinen Hosp, Dept Neurosurg, D-70174 Stuttgart, Germany
[3] Univ Tubingen, Hertie Inst Clin Brain Res, Mol Neurooncol Lab, D-72076 Tubingen, Germany
[4] Univ Tubingen, Ctr Neurol, D-72076 Tubingen, Germany
[5] KARL STORZ GmbH & Co KG, Dept Res & Technol, Tuttlingen, Germany
[6] Univ Marburg, Dept Neurosurg, D-35043 Marburg, Germany
关键词
Hypericin; Microendoscope; Glioma; Fluorescence visualization; Photodiagnosis; PHOTODYNAMIC THERAPY; MALIGNANT GLIOMA; IN-VITRO; GLIOBLASTOMA; NANOPARTICLES; CELLS; SENSITIVITY; PDT;
D O I
10.1016/j.pdpdt.2013.06.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: New treatment strategies for malignant gliomas are indispensible, due to the poor prognosis for patients. Fluorescence diagnosis (FD) and photodynamic therapy (PDT) are currently under intensive investigation and seem to improve the prognosis. Especially for deep seated malignant brain lesions and in order to optimize therapy new diagnostic tools are needed. Methods: In a syngeneic subcutaneous glioma mouse model we investigated the time dependent hypericin (HYP) uptake in malignant tumor tissue by microendoscopically fluorescence measurements. The HYP fluorescence in tumor was also detected by fluorescence microscopy (FM) and was compared to endoscopic data. Results: Both methods, microendoscopy and FM, demonstrated time dependent HYP uptake in subcutaneously implanted mouse glioma. Maximum of HYP uptake was achieved after 6 h, measured with both methods. FM reached a 10-fold increase in fluorescence intensity compared to the autofluorescence. Measured by microendoscopy a 2.2-fold HYP fluorescence intensity compared to the autofluorescence was detected. Microendoscopy enables visualization of small vessels even in healthy brain tissue by intravascular HYP fluorescence. Conclusion: The new developed microendoscope enables not only fluorescence based discrimination of tumor and healthy tissue, but also semiquantitative measurements of fluorescence intensities in vivo. Individual repetitive fluorescence diagnosis will become possible by this method and opens up new possibilities for determining optimal settings of light applications for PDT. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:552 / 560
页数:9
相关论文
共 50 条
  • [21] Effects of Matrigel on the SF-767 malignant glioma athymic mouse tumor model
    Wyrick, BJ
    Ozawa, T
    Lamborn, KR
    Bollen, AW
    Deen, DF
    ANTICANCER RESEARCH, 1997, 17 (4A) : 2419 - 2425
  • [22] Antitumor effect of immunizations with fusions of dendritic and glioma cells in a mouse brain tumor model
    Akasaki, Y
    Kikuchi, T
    Homma, S
    Abe, T
    Kofe, D
    Ohno, T
    JOURNAL OF IMMUNOTHERAPY, 2001, 24 (02): : 106 - 113
  • [23] MIP-1α antagonizes the effect of a GM-CSF-enhanced subcutaneous vaccine in a mouse glioma model
    Herrlinger, U
    Aulwurm, S
    Strik, H
    Weit, S
    Naumann, U
    Weller, M
    JOURNAL OF NEURO-ONCOLOGY, 2004, 66 (1-2) : 147 - 154
  • [24] MIP-1α Antagonizes the Effect of a GM-CSF-Enhanced Subcutaneous Vaccine in a Mouse Glioma Model
    Ulrich Herrlinger
    Steffen Aulwurm
    Herwig Strik
    Simone Weit
    Ulrike Naumann
    Michael Weller
    Journal of Neuro-Oncology, 2004, 66 : 147 - 154
  • [25] Novel photodynamic diagnosis of bladder cancer:: Ex vivo fluorescence cytology using hypericin
    Olivo, M
    Lau, W
    Manivasager, V
    Bhuvaneswari, R
    Wei, Z
    Soo, KC
    Cheng, C
    Tan, PH
    INTERNATIONAL JOURNAL OF ONCOLOGY, 2003, 23 (06) : 1501 - 1504
  • [26] Study of photosensitizers pharmacokinetics in mouse tumor model by transillumination fluorescence imaging in vivo
    Shirmanova, Marina V.
    Balalaeva, Irina V.
    Sirotkina, Marina A.
    Lekanova, Natalya Yu.
    Turchin, Ilya V.
    Zagainova, Elena V.
    OPTICAL METHODS FOR TUMOR TREATMENT AND DETECTION: MECHANISMS AND TECHNIQUES IN PHOTODYNAMIC THERAPY XX, 2011, 7886
  • [27] Advantages of a dual-color fluorescence-tracing glioma. orthotopic implantation model: Detecting tumor location, angiogenesis, cellular fusion and the tumor microenvironment
    Shen, Yuntian
    Zhang, Quanbin
    Zhang, Jinshi
    Lu, Zhaohui
    Wang, Aidong
    Fei, Xifeng
    Dai, Xingliang
    Wu, Jinding
    Wang, Zhimin
    Zhao, Yaodong
    Tian, Ye
    Dong, Jun
    Lan, Qing
    Huang, Qiang
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 10 (06) : 2047 - 2054
  • [28] Far-Red Fluorescent Murine Glioma Model for Accurate Assessment of Brain Tumor Progression
    Mishchenko, Tatiana A.
    Balalaeva, Irina, V
    Klimenko, Maria O.
    Brilkina, Anna A.
    Peskova, Nina N.
    Guryev, Evgenii L.
    Krysko, Dmitri, V
    Vedunova, Maria V.
    CANCERS, 2022, 14 (15)
  • [29] Interventional fluorescence spectroscopy: preliminary results to detect tumor margins during glioma resection with two fluorescence spectra of PpIX
    Alston, L. M.
    Guyotat, J.
    Mahieu-Williame, L.
    Hebert, M.
    Kantapareddy, P.
    Meyronet, D.
    Rousseau, D.
    Montcel, B.
    CLINICAL AND PRECLINICAL OPTICAL DIAGNOSTICS, 2017, 10411
  • [30] Temozolomide/PLGA microparticles plus vatalanib inhibits tumor growth and angiogenesis in an orthotopic glioma model
    Zhang, Yu-Hui
    Yue, Zhi-Jian
    Zhang, He
    Tang, Gu-Sheng
    Wang, Yang
    Liu, Jian-Min
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2010, 76 (03) : 371 - 375