Microendoscopy for hypericin fluorescence tumor diagnosis in a subcutaneous glioma mouse model

被引:9
|
作者
Noell, Susan [1 ]
Feigl, Guenther C. [1 ,2 ]
Serifi, Dzenan [1 ]
Mayer, Daniel [1 ]
Naumann, Ulrike [3 ,4 ]
Goebel, Werner [5 ]
Ehrhardt, Andre [5 ]
Ritz, Rainer [1 ,6 ]
机构
[1] Univ Tubingen, Dept Neurosurg, D-72076 Tubingen, Germany
[2] Katharinen Hosp, Dept Neurosurg, D-70174 Stuttgart, Germany
[3] Univ Tubingen, Hertie Inst Clin Brain Res, Mol Neurooncol Lab, D-72076 Tubingen, Germany
[4] Univ Tubingen, Ctr Neurol, D-72076 Tubingen, Germany
[5] KARL STORZ GmbH & Co KG, Dept Res & Technol, Tuttlingen, Germany
[6] Univ Marburg, Dept Neurosurg, D-35043 Marburg, Germany
关键词
Hypericin; Microendoscope; Glioma; Fluorescence visualization; Photodiagnosis; PHOTODYNAMIC THERAPY; MALIGNANT GLIOMA; IN-VITRO; GLIOBLASTOMA; NANOPARTICLES; CELLS; SENSITIVITY; PDT;
D O I
10.1016/j.pdpdt.2013.06.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: New treatment strategies for malignant gliomas are indispensible, due to the poor prognosis for patients. Fluorescence diagnosis (FD) and photodynamic therapy (PDT) are currently under intensive investigation and seem to improve the prognosis. Especially for deep seated malignant brain lesions and in order to optimize therapy new diagnostic tools are needed. Methods: In a syngeneic subcutaneous glioma mouse model we investigated the time dependent hypericin (HYP) uptake in malignant tumor tissue by microendoscopically fluorescence measurements. The HYP fluorescence in tumor was also detected by fluorescence microscopy (FM) and was compared to endoscopic data. Results: Both methods, microendoscopy and FM, demonstrated time dependent HYP uptake in subcutaneously implanted mouse glioma. Maximum of HYP uptake was achieved after 6 h, measured with both methods. FM reached a 10-fold increase in fluorescence intensity compared to the autofluorescence. Measured by microendoscopy a 2.2-fold HYP fluorescence intensity compared to the autofluorescence was detected. Microendoscopy enables visualization of small vessels even in healthy brain tissue by intravascular HYP fluorescence. Conclusion: The new developed microendoscope enables not only fluorescence based discrimination of tumor and healthy tissue, but also semiquantitative measurements of fluorescence intensities in vivo. Individual repetitive fluorescence diagnosis will become possible by this method and opens up new possibilities for determining optimal settings of light applications for PDT. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:552 / 560
页数:9
相关论文
共 50 条
  • [1] Accumulation and penetration behavior of hypericin in glioma tumor spheroids studied by fluorescence microscopy and confocal fluorescence lifetime imaging microscopy
    Bassler, Miriam C.
    Rammler, Tim
    Wackenhut, Frank
    Zur Oven-Krockhaus, Sven
    Secic, Ivona
    Ritz, Rainer
    Meixner, Alfred J.
    Brecht, Marc
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (17) : 4849 - 4860
  • [2] Accumulation and penetration behavior of hypericin in glioma tumor spheroids studied by fluorescence microscopy and confocal fluorescence lifetime imaging microscopy
    Miriam C. Bassler
    Tim Rammler
    Frank Wackenhut
    Sven zur Oven-Krockhaus
    Ivona Secic
    Rainer Ritz
    Alfred J. Meixner
    Marc Brecht
    Analytical and Bioanalytical Chemistry, 2022, 414 : 4849 - 4860
  • [3] Dual-color fluorescence imaging in a nude mouse orthotopic glioma model
    Zhang, Xuepeng
    Zheng, Xuguang
    Jiang, Feng
    Zhang, Zheng Gang
    Katakowski, Mark
    Chopp, Michael
    JOURNAL OF NEUROSCIENCE METHODS, 2009, 181 (02) : 178 - 185
  • [4] Photodynamic therapy with hypericin in a mouse P388 tumor model:: vascular effects determine the efficacy
    Chen, B
    Zupkó, I
    De Witte, PA
    INTERNATIONAL JOURNAL OF ONCOLOGY, 2001, 18 (04) : 737 - 742
  • [5] Photodynamic therapy efficacy and tissue distribution of hypericin in a mouse P388 lymphoma tumor model
    Chen, B
    de Witte, PA
    CANCER LETTERS, 2000, 150 (01) : 111 - 117
  • [6] Photodynamic therapy with hypericin induces vascular damage and apoptosis in the RIF-1 mouse tumor model
    Chen, B
    Roskams, T
    Xu, Y
    Agostinis, P
    de Witte, PAM
    INTERNATIONAL JOURNAL OF CANCER, 2002, 98 (02) : 284 - 290
  • [7] Hypericin-based fluorescence diagnosis of bladder carcinoma
    D'Hallewin, MA
    Kamuhabwa, AR
    Roskams, T
    De Witte, PAM
    Baert, L
    BJU INTERNATIONAL, 2002, 89 (07) : 760 - 763
  • [8] Successful in vivo tumor visualization using fluorescence laparoscopy in a mouse model of disseminated alveolar rhabdomyosarcoma
    Urla, Cristian
    Armeanu-Ebinger, Sorin
    Fuchs, Joerg
    Seitz, Guido
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (05): : 1105 - 1114
  • [9] Fluorescence lifetime imaging unravels the pathway of glioma cell death upon hypericin-induced photodynamic therapy
    Bassler, Miriam C.
    Hiller, Jonas
    Wackenhut, Frank
    zur Oven-Krockhaus, Sven
    Frech, Philipp
    Schmidt, Felix
    Kertzscher, Christoph
    Rammler, Tim
    Ritz, Rainer
    Braun, Kai
    Scheele, Marcus
    Meixner, Alfred J.
    Brecht, Marc
    RSC CHEMICAL BIOLOGY, 2024, 5 (12): : 1219 - 1231
  • [10] Biodistribution and photodynamic therapy with hypericin in a human NPC murine tumor model
    Du, HY
    Bay, BH
    Olivo, M
    INTERNATIONAL JOURNAL OF ONCOLOGY, 2003, 22 (05) : 1019 - 1024