Rotational radiotherapy of breast cancer with polyenergetic kilovoltage X-ray beams: An experimental and Monte Carlo phantom study

被引:11
作者
Buonanno, F. [1 ,2 ]
Sarno, A. [1 ,2 ]
De Lucia, P. A. [1 ,3 ]
Di Lillo, F. [1 ,2 ]
Masi, M. [1 ,2 ,4 ]
Di Franco, F. [1 ,2 ]
Mettivier, G. [1 ,2 ]
Russo, P. [1 ,2 ]
机构
[1] Univ Napoli Federico II, Dipartimento Fis Ettore Pancini, I-80126 Naples, Italy
[2] Ist Nazl Fis Nucl, Sez Napoli, I-80126 Naples, Italy
[3] Malzoni Radiosurg Ctr, Via Marrota 1, I-84043 Salerno, Italy
[4] Univ Roma Tor Vergata, Sez Fis Med, I-00133 Rome, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 62卷
关键词
Breast cancer; Rotational kilovoltage radiotherapy; Computed tomography; Monte Carlo simulations; RADIATION-THERAPY; SIMULATIONS;
D O I
10.1016/j.ejmp.2019.05.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigated the feasibility of kilovoltage rotational radiotherapy for breast cancer (kV-EBRT) via Monte Carlo simulations and measurements on phantoms. Methods: We derived the dose distributions for X-ray beams at 150 kV, 300 kVp and 320 kV irradiating breast cylindrical phantoms of 14 cm diameter, mimicking the pendant breast. Simulations were based on the Geant4 toolkit. The point-like X-ray source was rotated either over a full circle or on a limited arc around the phantom. We studied the influence on the surface dose of the distance between the tumor lesion to the skin, of the irradiation protocol (full scan or partial scan) and of the X-ray tube current modulation. Results: Rotational kV-EBRT permitted a periphery-to-center dose ratio from 13% to 9% in homogeneous breast phantoms. Dose distributions in phantoms with off-center simulated lesions, showed a skin-to-tumor dose ratio of 16% and 34% for lesions at 3.25 and 5.25 cm from cylinder axis, respectively. Simulation of the X-ray tube current modulation during the rotation, permits to reach a dose ratio of 20% for the lesion located at 5.25 cm from phantom axis. Conclusions: We showed the possibility of using low-energy X-ray spectra for kV-EBRT with collimated beams, for obtaining a periphery-to-center dose ratio in the same order of conventional accelerator based megavoltage radiotherapy, when the irradiated area is localized in the center of the breast. For tumors localized near the breast border, we showed that the tube current modulation can be a good solution in order to reduce the skin-totumor dose ratio.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 19 条
[1]   Global Access to Radiotherapy in Low- and Middle-income Countries [J].
Abdel-Wahab, M. ;
Fidarova, E. ;
Polo, A. .
CLINICAL ONCOLOGY, 2017, 29 (02) :99-104
[2]  
[Anonymous], RAND PHAS 3 STUD CON
[3]   Feasibility of external beam radiation therapy to deep-seated targets with kilovoltage x-rays [J].
Bazalova-Carter, Magdalena ;
Weil, Michael D. ;
Breitkreutz, Dylan Yamabe ;
Wilfley, Brian P. ;
Graves, Edward E. .
MEDICAL PHYSICS, 2017, 44 (02) :597-607
[4]   Inverse optimization of low-cost kilovoltage x-ray arc therapy plans [J].
Breitkreutz, Dylan Y. ;
Renaud, Marc-Andre ;
Seuntjens, Jan ;
Weil, Michael D. ;
Zavgorodni, Sergei ;
Bazalova-Carter, Magdalena .
MEDICAL PHYSICS, 2018, 45 (11) :5161-5171
[5]   Monte Carlo simulations of a kilovoltage external beam radiotherapy system on phantoms and breast patients [J].
Breitkreutz, Dylan Y. ;
Weil, Michael D. ;
Zavgorodni, Sergei ;
Bazalova-Carter, Magdalena .
MEDICAL PHYSICS, 2017, 44 (12) :6548-6559
[6]   Radiation Therapy Infrastructure and Human Resources in Low- and Middle-Income Countries: Present Status and Projections for 2020 [J].
Datta, Niloy R. ;
Samiei, Massoud ;
Bodis, Stephan .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 89 (03) :448-457
[7]  
De Lucia PA, 2015, THESIS
[8]   Synchrotron radiation external beam rotational radiotherapy of breast cancer: proof of principle [J].
Di Lillo, Francesca ;
Mettivier, Giovanni ;
Castriconi, Roberta ;
Sarno, Antonio ;
Stevenson, Andrew W. ;
Hall, Chris J. ;
Hausermann, Daniel ;
Russo, Paolo .
JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 :857-868
[9]   Towards breast cancer rotational radiotherapy with synchrotron radiation [J].
Di Lillo, Francesca ;
Mettivier, Giovanni ;
Sarno, Antonio ;
Castriconi, Roberta ;
Russo, Paolo .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 :20-25
[10]   Suitability of low density materials for 3D printing of physical breast phantoms [J].
Ivanov, Danail ;
Bliznakova, Kristina ;
Buliev, Ivan ;
Popov, Peycho ;
Mettivier, Giovanni ;
Russo, Paolo ;
Di Lillo, Francesca ;
Sarno, Antonio ;
Vignero, Janne ;
Bosmans, Hilde ;
Bravin, Alberto ;
Bliznakov, Zhivko .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (17)