A novel Al2O3 fluorescent nuclear track detector for heavy charged particles and neutrons

被引:111
作者
Akselrod, G. M.
Akselrod, M. S.
Benton, E. R.
Yasuda, N.
机构
[1] Landauer Inc, Stillwater Crystal Growth Div, Stillwater, OK 74074 USA
[2] Eril Res Inc, Stillwater, OK 74074 USA
[3] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
关键词
radiation measurements; nuclear track detectors; heavy charged particles; linear energy transfer; confocal fluorescence microscopy; aluminum oxide crystals; three-dimensional imaging;
D O I
10.1016/j.nimb.2006.01.056
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel Al2O3 fluorescent nuclear track detector (FNTD), recently developed by Landauer, Inc., has demonstrated sensitivity and functionality superior to that of existing nuclear track detectors. The FNTD is based on single crystals of aluminum oxide doped with carbon and magnesium, and having aggregate oxygen vacancy defects (Al2O3:C,Mg). Radiation-induced color centers in the new material have an absorption band at 620 nm and produce fluorescence at 750 nm with a high quantum yield and a short, 75 +/- 5 ns, fluorescence lifetime. Non-destructive readout of the detector is performed using a confocal fluorescence microscope. Scanning of the three-dimensional spatial distribution of fluorescence intensity along the track of a heavy charged particle (RCP) permits reconstruction of particle trajectories through the crystal and the LET can be determined as a function of distance along the trajectory based on the fluorescence intensity. Major advantages of Al2O3:C,Mg FNTD over conventionally processed CR-39 plastic nuclear track detector include superior spatial resolution, a wider range of LET sensitivity, no need for post-irradiation chemical processing of the detector and the capability to anneal and reuse the detector. Preliminary experiments have demonstrated that the material possesses a low-LET threshold of < 1 keV/mu m, does not saturate at LET in water as high as 1800 keV/mu m, and is capable of irradiation to fluences in excess of 10(6) cm(-2) without saturation (track overlap). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:295 / 306
页数:12
相关论文
共 17 条
  • [1] AKSELROD MS, 1990, RADIAT PROT DOSIM, V32, P15
  • [2] A radiation dosimetry method using pulsed optically stimulated luminescence
    Akselrod, MS
    McKeever, SWS
    [J]. RADIATION PROTECTION DOSIMETRY, 1999, 81 (03) : 167 - 176
  • [3] Bit-wise volumetric optical memory utilizing two-photon absorption in aluminum oxide medium
    Akselrod, MS
    Orlov, SS
    Akselrod, GM
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2004, 43 (7B): : 4908 - 4911
  • [4] Fluorescent aluminum oxide crystals for volumetric optical data storage and imaging applications
    Akselrod, MS
    Akselrod, AE
    Orlov, SS
    Sanyal, S
    Underwood, TH
    [J]. JOURNAL OF FLUORESCENCE, 2003, 13 (06) : 503 - 511
  • [5] AKSELROD MS, 2004, 14 INT C SOL STAT DO
  • [6] AKSELROD MS, 2005, Patent No. 6864434
  • [7] AKSELROD MS, 2005, Patent No. 6950382
  • [8] Passive dosimetry aboard the Mir Orbital Station: Internal measurements
    Benton, Eric R.
    Benton, E.V.
    Frank, A.L.
    [J]. 2002, Elsevier Ltd (35)
  • [9] Space radiation dosimetry in low-Earth orbit and beyond
    Benton, ER
    Benton, E
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 184 (1-2) : 255 - 294
  • [10] RESTRUCTED ENERGY LOSS CRITERION FOR REGISTRATION OF CHARGED PARTICLES IN PLASTICS
    BENTON, EV
    NIX, WD
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1969, 67 (02): : 343 - &