Developing new extension of GafChromic RTQA2 film to patient quality assurance field using a plan-based calibration method

被引:5
作者
Peng, Jiayuan [1 ,2 ]
Zhang, Zhen [1 ,2 ]
Wang, Jiazhou [1 ,2 ]
Xie, Jiang [1 ,2 ]
Chen, Junchao [1 ,2 ]
Hu, Weigang [1 ,2 ]
机构
[1] Fudan Univ, Shanghai Canc Ctr, Dept Radiat Oncol, Shanghai 200433, Peoples R China
[2] Fudan Univ, Shanghai Med Coll, Dept Oncol, Shanghai 200433, Peoples R China
关键词
film dosimetry; GafChromic RTQA film; patient specific QA; plan-based film calibration; RADIOCHROMIC FILM; EBT FILM; DOSIMETRY; VERIFICATION;
D O I
10.1088/0031-9155/60/19/7533
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
GafChromic RTQA2 film is a type of radiochromic film designed for light field and radiation field alignment. The aim of this study is to extend the application of RTQA2 film to the measurement of patient specific quality assurance (QA) fields as a 2D relative dosimeter. Pre-irradiated and post-irradiated RTQA2 films were scanned in reflection mode using a flatbed scanner. A plan-based calibration (PBC) method utilized the mapping information of the calculated dose image and film grayscale image to create a dose versus pixel value calibration model. This model was used to calibrate the film grayscale image to the film relative dose image. The dose agreement between calculated and film dose images were analyzed by gamma analysis. To evaluate the feasibility of this method, eight clinically approved RapidArc cases (one abdomen cancer and seven head-and-neck cancer patients) were tested using this method. Moreover, three MLC gap errors and two MLC transmission errors were introduced to eight Rapidarc cases respectively to test the robustness of this method. The PBC method could overcome the film lot and post-exposure time variations of RTQA2 film to get a good 2D relative dose calibration result. The mean gamma passing rate of eight patients was 97.90% +/- 1.7%, which showed good dose consistency between calculated and film dose images. In the error test, the PBC method could over-calibrate the film, which means some dose error in the film would be falsely corrected to keep the dose in film consistent with the dose in the calculated dose image. This would then lead to a false negative result in the gamma analysis. In these cases, the derivative curve of the dose calibration curve would be non-monotonic which would expose the dose abnormality. By using the PBC method, we extended the application of more economical RTQA2 film to patient specific QA. The robustness of the PBC method has been improved by analyzing the monotonicity of the derivative of the calibration curve.
引用
收藏
页码:7533 / 7542
页数:10
相关论文
共 25 条
  • [1] On the characterization and uncertainty analysis of radiochromic film dosimetry
    Bouchard, Hugo
    Lacroix, Frederic
    Beaudoin, Gilles
    Carrier, Jean-Francois
    Kawrakow, Iwan
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 1931 - 1946
  • [2] Chan Maria F, 2014, Int J Med Phys Clin Eng Radiat Oncol, V3, P25
  • [3] Charland Paule M, 2003, J Appl Clin Med Phys, V4, P25, DOI 10.1120/1.1522990
  • [4] Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry
    Chetty, IJ
    Charland, PM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (20) : 3629 - 3641
  • [5] Precise radiochromic film dosimetry using a flat-bed document scanner
    Devic, S
    Seuntjens, J
    Sham, E
    Podgorsak, EB
    Schmidtlein, CR
    Kirov, AS
    Soares, CG
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2245 - 2253
  • [6] Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy
    Dogan, N
    Leybovich, LB
    Sethi, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22) : 4121 - 4130
  • [7] Commissioning Varian enhanced dynamic wedge in the PINNACLE treatment planning system using Gafchromic™ EBT film
    Fontanarosa, Davide
    Orlandini, Lucia Clara
    Andriani, Italo
    Bernardi, Luca
    [J]. MEDICAL PHYSICS, 2009, 36 (10) : 4504 - 4510
  • [8] Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance
    Fuss, Martina
    Sturtewagen, Eva
    De Wagter, Carlos
    Georg, Dietmar
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14) : 4211 - 4225
  • [9] EBT2 radiochromic film for quality assurance of complex IMRT treatments of the prostate: micro-collimated IMRT, RapidArc, and TomoTherapy
    Kairn, T.
    Hardcastle, N.
    Kenny, J.
    Meldrum, R.
    Tome, W. A.
    Aland, T.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (03) : 333 - 343
  • [10] An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan
    Lewis, David
    Micke, Andre
    Yu, Xiang
    Chan, Maria F.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6339 - 6350