X-ray detector calibration in the PTB radiometry laboratory at the electron storage ring BESSY II

被引:41
|
作者
Beckhoff, B [1 ]
Klein, R [1 ]
Krumrey, M [1 ]
Scholze, F [1 ]
Thornagel, R [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2000年 / 444卷 / 1-2期
关键词
radiometry; detector calibration; synchrotron radiation;
D O I
10.1016/S0168-9002(99)01427-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Physikalisch-Technische Bundesanstalt (PTB) currently operates a laboratory for radiometry from the VUV to the hard X-ray spectral range at the 1.7 GeV electron storage ring BESSY II. Detector calibration, performed by the PTB at BESSY I up to photon energies of about 1.5 keV, can now be extended up to 10.5 keV based on an electrical substitution radiometer as a primary detector standard and on the use of monochromatized bending magnet and undulator radiation of high spectral purity. This energetic range will be further extended up to 50 keV by using radiation from a 7 T wavelength shifter. Moreover, BESSY II is a primary source standard offering calculable bending magnet radiation. The PTB uses these primary standards for the absolute calibration of detectors with relative uncertainties below 1%. Up until now, photodiodes, energy-dispersive semiconductor detectors and also superconducting tunnel junctions have been characterized for photon energies up to 10.5 keV. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:480 / 483
页数:4
相关论文
共 50 条
  • [21] The transmission X-ray microscope at BESSY II
    Guttmann, P
    Niemann, B
    Rehbein, S
    Knöchel, C
    Rudolph, D
    Schmahl, G
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 85 - 90
  • [22] X-ray spectromicroscopy with the scanning transmission X-ray microscope at BESSY II
    Mitrea, G.
    Thieme, J.
    Guttmann, P.
    Heim, S.
    Gleber, S.
    JOURNAL OF SYNCHROTRON RADIATION, 2008, 15 : 26 - 35
  • [23] A Review of X-Ray Imaging at the BAMline (BESSY II)
    Markoetter, Henning
    Mueller, Bernd Randolf
    Kupsch, Andreas
    Evsevleev, Sergei
    Arlt, Tobias
    Ulbricht, Alexander
    Dayani, Shahabeddin
    Bruno, Giovanni
    ADVANCED ENGINEERING MATERIALS, 2023, 25 (11)
  • [24] A soft x-ray fluorescence spectrometer at BESSY II
    Follath, R.
    Bischoff, P.
    Eggenstein, F.
    Noll, T.
    Koennecke, R.
    Schlappa, J.
    Zeschke, T.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [25] Layout of a femtosecond x-ray source at BESSY II
    Bäcker, HJ
    Bahrdt, J
    Dürr, HA
    Durr, V
    Eberhardt, W
    Gaupp, A
    Jaeschke, E
    Holldack, K
    Khan, S
    Krämer, D
    Mertins, HC
    Peatman, WB
    Reichardt, G
    Quast, T
    Scheer, M
    Senf, F
    Wüstefeld, G
    Hertel, I
    Noack, F
    Sandner, W
    Will, I
    Zhavoronkov, N
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 836 - 838
  • [26] High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory
    Scholze, F
    Henneken, H
    Kuschnerus, P
    Rabus, H
    Richter, M
    Ulm, G
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 866 - 868
  • [27] High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory
    Phys.-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin, Germany
    J. Synchrotron Radiat., 3 (866-868):
  • [28] The new scanning transmission X-ray microscope at BESSY II
    Wieseman, U
    Thieme, J
    Guttmann, P
    Niemann, B
    Rudolph, D
    Schmahl, G
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 430 - 434
  • [30] Characterization of the soft X-ray spectrometer PEAXIS at BESSY II
    Schulz, Christian
    Lieutenant, Klaus
    Xiao, Jie
    Hofmann, Tommy
    Wong, Deniz
    Habicht, Klaus
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 (27) : 238 - 249