X-ray detector calibration in the PTB radiometry laboratory at the electron storage ring BESSY II

被引:41
作者
Beckhoff, B [1 ]
Klein, R [1 ]
Krumrey, M [1 ]
Scholze, F [1 ]
Thornagel, R [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
radiometry; detector calibration; synchrotron radiation;
D O I
10.1016/S0168-9002(99)01427-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Physikalisch-Technische Bundesanstalt (PTB) currently operates a laboratory for radiometry from the VUV to the hard X-ray spectral range at the 1.7 GeV electron storage ring BESSY II. Detector calibration, performed by the PTB at BESSY I up to photon energies of about 1.5 keV, can now be extended up to 10.5 keV based on an electrical substitution radiometer as a primary detector standard and on the use of monochromatized bending magnet and undulator radiation of high spectral purity. This energetic range will be further extended up to 50 keV by using radiation from a 7 T wavelength shifter. Moreover, BESSY II is a primary source standard offering calculable bending magnet radiation. The PTB uses these primary standards for the absolute calibration of detectors with relative uncertainties below 1%. Up until now, photodiodes, energy-dispersive semiconductor detectors and also superconducting tunnel junctions have been characterized for photon energies up to 10.5 keV. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:480 / 483
页数:4
相关论文
共 9 条
  • [1] Development of superconducting tunnel junction detectors for high-resolution X-ray spectroscopy
    Angloher, G
    Beckhoff, B
    Bühler, M
    von Feilitzsch, F
    Hertrich, T
    Hettl, P
    Höhne, J
    Huber, M
    Jochum, J
    Mössbauer, RL
    Schnagl, J
    Scholze, F
    Ulm, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) : 214 - 219
  • [2] ELECTRON STORAGE RING BESSY AS A SOURCE OF CALCULABLE SPECTRAL PHOTON FLUX IN THE X-RAY REGION
    ARNOLD, D
    ULM, G
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) : 1539 - 1542
  • [3] Synchrotron-radiation-operated cryogenic electrical-substitution radiometer as the high-accuracy primary detector standard in the ultraviolet, vacuum-ultraviolet, and soft-x-ray spectral ranges
    Rabus, H
    Persch, V
    Ulm, G
    [J]. APPLIED OPTICS, 1997, 36 (22) : 5421 - 5440
  • [4] Detector calibration at the PTB radiometry laboratory at BESSY
    Rabus, H
    Scholze, F
    Thornagel, R
    Ulm, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) : 209 - 216
  • [5] High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory
    Scholze, F
    Henneken, H
    Kuschnerus, P
    Rabus, H
    Richter, M
    Ulm, G
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 866 - 868
  • [6] The electron storage ring BESSY as a primary standard source - A radiometric comparison with a cryogenic electrical substitution radiometer in the visible
    Thornagel, R
    Fischer, J
    Friedrich, R
    Stock, M
    Ulm, G
    Wende, B
    [J]. METROLOGIA, 1996, 32 (06) : 459 - 462
  • [7] The PTB radiometry laboratory at the BESSY II electron storage ring
    Ulm, G
    Beckhoff, B
    Klein, R
    Krumrey, M
    Rabus, H
    Thornagel, R
    [J]. X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 : 610 - 621
  • [8] ULM G, 1997, RONTGEN CENTENNIAL, P81
  • [9] Response of niobium-based superconducting tunnel junctions in the soft-x-ray region 0.15-6.5 keV
    Verhoeve, P
    Rando, N
    Verveer, J
    Peacock, A
    vanDordrecht, A
    Videler, P
    Bavdaz, M
    Goldie, DJ
    Lederer, T
    Scholze, F
    Ulm, G
    Venn, R
    [J]. PHYSICAL REVIEW B, 1996, 53 (02): : 809 - 817