Volumetric (3D) imaging reduces inter- and intraobserver variation of fetal biometry measurements

被引:28
作者
Chan, L. W. [1 ]
Fung, T. Y. [1 ]
Leung, T. Y. [1 ]
Sahota, D. S. [1 ]
Lau, T. K. [1 ]
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Obstet & Gynaecol, Fetal Med Unit, Hong Kong, Hong Kong, Peoples R China
关键词
2D ultrasound; 3D ultrasound; fetal biometry; interobserver variation; intraobserver variation; REPRODUCIBILITY; FETUS;
D O I
10.1002/uog.6321
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective TO compare the inter- and intraobserver variation of fetal biometric measurements utilizing two-dimensional (2D) and three-dimensional (3D) ultrasound imaging. Methods This prospective study, utilizing three pairs of doctors trained in sonography, evaluated singleton pregnancies in the mid-trimester. Measurements of the biparietal diameter (BPD), bead circumference (HC), abdominal circumference (AC) and femur length (FL) were taken in duplicate by each doctor using 2D imaging and then again using 3D volume datasets. Each set of paired doctors evaluated 12 patients. Inter- and intraobserver variation were calculated as the SD of the difference between paired measurements performed by the doctor pairs and by the individual doctors, respectively. Bland-Altman plots were used to visually compare measurement bias and agreement by 2D and 3D methods. Results Inter- and intraobserver variation for 2D and 3D ultrasound were small. The intraobserver variation of HC, AC and FL was significantly lower for 3D compared with 2D ultrasound. Interobserver variation was not significantly different when measured with 2D and 3D ultrasound, with The exception of FL, which was lower when measured with 3D ultrasound. The Bland-Altman plots showed that in 95% of the measurements, the percentage difference between 2D and 3D ultrasound techniques was within 5.3%, 4.6%, 9.6% and 9.6% for BPD, HC, AC and FL, respectively. Conclusions 2D and 3D fetal biometric measurements are reproducible. The use of 3D ultrasound significantly reduces intraobserver variation for HC, AC and FL and reduces interobserver variation for FL. Copyright (C) 2009 ISUOG, Published by John Wiley & Sons, Ltd.
引用
收藏
页码:447 / 452
页数:6
相关论文
共 10 条
  • [1] Three-dimensional US of the fetus: Volume imaging
    Benacerraf, BR
    Shipp, TD
    Bromley, B
    [J]. RADIOLOGY, 2006, 238 (03) : 988 - 996
  • [2] How sonographic tomography will change the face of obstetric sonography - A pilot study
    Benacerraf, BR
    Shipp, TD
    Bromley, B
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (03) : 371 - 378
  • [3] Assessment of the third-trimester fetus using 3-dimensional volumes: A pilot study
    Bromley, Bryann
    Shipp, Thomas D.
    Benacerraf, Beryl
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 2007, 35 (05) : 231 - 237
  • [4] QUALITY ASSURANCE IN OBSTETRIC ULTRASOUND
    DUDLEY, NJ
    POTTER, R
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790) : 865 - 870
  • [5] The importance of quality management in fetal measurement
    Dudley, NJ
    Chapman, E
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2002, 19 (02) : 190 - 196
  • [6] A novel algorithm for comprehensive fetal echocardiography using 4-dimensional ultrasonography and tomographic imaging
    Espinoza, Jimmy
    Kusanovic, Juan Pedro
    Goncalves, Luis F.
    Nien, Jyh Kae
    Hassan, Sonia
    Lee, Wesley
    Romero, Roberto
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (08) : 947 - 956
  • [7] REPEATABILITY OF MEASUREMENT OF FETAL NUCHAL TRANSLUCENCY THICKNESS
    PANDYA, PP
    ALTMAN, DG
    BRIZOT, ML
    PETTERSEN, H
    NICOLAIDES, KH
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 5 (05) : 334 - 337
  • [8] Intraobserver and interobserver reproducibility of fetal biometry
    Perni, SC
    Chervenak, FA
    Kalish, RB
    Magherini-Rothe, S
    Predanic, M
    Streltzoff, J
    Skupski, DW
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 24 (06) : 654 - 658
  • [9] Feasibility and reproducibility of an image-scoring method for quality control of fetal biometry in the second trimester
    Salomon, LJ
    Bernard, JP
    Duyme, M
    Doris, B
    Mas, N
    Ville, Y
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (01) : 34 - 40
  • [10] Cumulative sum (CUSUM) analysis in the assessment of trainee competence in fetal biometry measurement
    Weerasinghe, S.
    Mirghani, H.
    Revel, A.
    Abu-Zidan, F. M.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (02) : 199 - 203