Spectral analysis of ocular pulse amplitude recordings obtained using a contact lens sensor

被引:0
|
作者
Hirn, C. [1 ,2 ,3 ]
Russell, R. A. [2 ,3 ,4 ]
Lamparter, J. [2 ,3 ,5 ]
Lascaratos, G. [2 ,3 ]
Ho, T. [2 ,3 ]
Garway-Heath, D. F. [2 ,3 ]
机构
[1] Triemli Hosp, Zurich, Switzerland
[2] Moorfields Eye Hosp NHS Fdn Trust, NIHR Biomed Res Ctr, London, England
[3] UCL Inst Ophthalmol, London, England
[4] City Univ London, London, England
[5] Univ Med Ctr, Mainz, Germany
关键词
D O I
10.1111/j.1755-3768.2013.2727.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
2727
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry
    Hoffmann E.M.
    Grus F.-H.
    Pfeiffer N.
    BMC Ophthalmology, 4 (1) : 1 - 7
  • [2] Contact lens sensor for ocular inflammation monitoring
    Shi, Yuqi
    Wang, Lin
    Hu, Yubing
    Zhang, Yihan
    Le, Wenhao
    Liu, Guohui
    Tomaschek, Michael
    Jiang, Nan
    Yetisen, Ali K.
    BIOSENSORS & BIOELECTRONICS, 2024, 249
  • [3] Scleral Lens Sensor for Ocular Electrolyte Analysis
    Yetisen, Ali K.
    Jiang, Nan
    Gonzalez, Carmen M. Castaneda
    Erenoglu, Zeynep Izlen
    Dong, Jie
    Dong, Xingchen
    Stoesser, Simon
    Brischwein, Martin
    Butt, Haider
    Cordeiro, Maria F.
    Jakobi, Martin
    Hayden, Oliver
    Koch, Alexander W.
    ADVANCED MATERIALS, 2020, 32 (06)
  • [4] Spectral Analysis of Overnight Pulse Oximetry Recordings in Sleep Studies
    Schultheiss, Birgit
    Jozefiak-Wesolowska, Agnieszka
    Boehning, Nikolaus
    Schmittendorf, Eckhard
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 356 - 359
  • [5] Ocular pulse amplitude and Doppler waveform analysis in glaucoma patients
    Pinto, Luis Abegao
    Vandewalle, Evelien
    Willekens, Koen
    Marques-Neves, Carlos
    Stalmans, Ingeborg
    ACTA OPHTHALMOLOGICA, 2014, 92 (04) : e280 - e285
  • [6] Ocular delivery of cyclosporine A using dissolvable microneedle contact lens
    Datta, Deepanjan
    Roy, Girdhari
    Garg, Prashant
    Venuganti, Venkata Vamsi Krishna
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2022, 70
  • [7] Confocal analysis of the ocular tear film - contact lens interface
    Schatz, Scott
    Laubach, Harold
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [8] Utility of oxygen saturation and heart rate spectral analysis obtained from pulse oximetric recordings in the diagnosis of sleep apnea syndrome
    Zamarrón, C
    Gude, F
    Barcala, J
    Rodriguez, JR
    Romero, PV
    CHEST, 2003, 123 (05) : 1567 - 1576
  • [9] Reproducibility of measurements of ocular pulse amplitude and intraocular pressure using SmartLens®
    Vogel, A
    Beck, S
    Schwenn, O
    Grus, F
    Krummenauer, F
    Pfeiffer, N
    OPHTHALMOLOGE, 2001, 98 (10): : 944 - 949
  • [10] Estimation of Ocular Rigidity in Glaucoma Using Ocular Pulse Amplitude and Pulsatile Choroidal Blood Flow
    Wang, Jing
    Freeman, Ellen E.
    Descovich, Denise
    Harasymowycz, Paul J.
    Fansi, Alvine Kamdeu
    Li, Gisele
    Lesk, Mark R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (03) : 1706 - 1711