Frequent Versus Infrequent Monitoring of Endotracheal Tube Cuff Pressures

被引:33
作者
Letvin, Adam [1 ]
Kremer, Pamala [2 ]
Silver, Patty C. [3 ]
Samih, Nizama [3 ]
Reed-Watts, Peggy [3 ]
Kollef, Marin H. [1 ]
机构
[1] Washington Univ, Sch Med, Div Pulm & Crit Care Med, 4523 Clayton Ave,Campus Box 8052, St Louis, MO 63110 USA
[2] Barnes Jewish Hosp, Hosp Epidemiol & Infect Prevent Dept, St Louis, MO 63110 USA
[3] Barnes Jewish Hosp, Resp Care Serv, St Louis, MO 63110 USA
关键词
endotracheal tube; mechanical ventilation; ventilator-associated event; VENTILATOR-ASSOCIATED PNEUMONIA; RANDOMIZED CONTROLLED-TRIAL; MECHANICAL VENTILATION; CIRCUIT CHANGES; SEDATION PROTOCOL; METAANALYSIS; VOLUME; RISK;
D O I
10.4187/respcare.05926
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Currently there is no accepted standard of practice for the optimal frequency of endotracheal tube cuff pressure monitoring in mechanically ventilated patients. Therefore, we conducted a study to compare infrequent endotracheal tube cuff pressure monitoring (immediately after intubation and when clinically indicated for an observed air leak or due to tube migration) with frequent endotracheal tube cuff pressure monitoring (immediately after intubation, every 8 h, and when clinically indicated). METHODS: We performed a prospective clinical trial with subjects assigned to study groups based on room assignment. The primary outcome was the occurrence of a ventilator-associated event (VAE) and was adjudicated by individuals blinded to the conduct of this study. RESULTS: We enrolled 305 subjects, with 166 (54.4%) assigned to frequent monitoring and 139 (45.6%) assigned to infrequent monitoring. The total number of endotracheal tube cuff pressure monitoring events for both groups was 1,531 versus 336, respectively. The occurrence of VAEs was infrequent and similar for both groups (3.6% vs 5.8%, P = .37). Witnessed aspiration events (0.6% vs 0%, P = .36), ventilator-associated pneumonia (0% vs 0.7%, P = .27), 30-d mortality (31.3% vs 30.2%, P = .83), and hospital length of stay (10 d [6 d, 21 d] vs 11 d 16 d, 21 d], P = .34) were also similar for both study groups. The 30-d hospital readmission rate was statistically lower for the group that received infrequent monitoring (15.1% vs 6.5%, P = .02). CONCLUSIONS: More frequent cuff pressure monitoring was not associated with any identifiable clinical outcome benefit.
引用
收藏
页码:495 / 501
页数:7
相关论文
共 26 条
[1]  
[Anonymous], 2012, POWER CALCULATOR BIN
[2]   Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation [J].
Boisson, C ;
Viviand, X ;
Arnaud, S ;
Thomachot, L ;
Miliani, Y ;
Martin, C .
INTENSIVE CARE MEDICINE, 1999, 25 (11) :1237-1243
[3]   A Prospective Evaluation of Ventilator-Associated Conditions and Infection-Related Ventilator-Associated Conditions [J].
Boyer, Anthony F. ;
Schoenberg, Noah ;
Babcock, Hilary ;
McMullen, Kathleen M. ;
Micek, Scott T. ;
Kollef, Marin H. .
CHEST, 2015, 147 (01) :68-81
[4]   Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation [J].
Brook, AD ;
Ahrens, TS ;
Schaiff, R ;
Prentice, D ;
Sherman, G ;
Shannon, W ;
Kollef, MH .
CRITICAL CARE MEDICINE, 1999, 27 (12) :2609-2615
[5]   Achieving a Safe Endotracheal Tube Cuff Pressure in the Prehospital Setting: Is It Time to Revise the Standard Cuff Inflation Practice? [J].
Carhart, Elliot ;
Stuck, Logan H. ;
Salzman, Joshua G. .
PREHOSPITAL EMERGENCY CARE, 2016, 20 (02) :273-277
[6]  
CRAVEN DE, 1986, AM REV RESPIR DIS, V133, P792
[7]  
Danielis M, 2015, ASSIST INFERM RIC, V34, P15, DOI 10.1702/1812.19746
[8]   PROSPECTIVE-STUDY OF NOSOCOMIAL PNEUMONIA AND OF PATIENT AND CIRCUIT COLONIZATION DURING MECHANICAL VENTILATION WITH CIRCUIT CHANGES EVERY 48 HOURS VERSUS NO CHANGE [J].
DREYFUSS, D ;
DJEDAINI, K ;
WEBER, P ;
BRUN, P ;
LANORE, JJ ;
RAHMANI, J ;
BOUSSOUGANT, Y ;
COSTE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (04) :738-743
[9]   Endotracheal Tubes: Old and New [J].
Haas, Carl F. ;
Eakin, Richard M. ;
Konkle, Mark A. ;
Blank, Ross .
RESPIRATORY CARE, 2014, 59 (06) :933-952
[10]  
Han JN, 2010, RESP CARE, V55, P467