Phase angle-based PC technique for islanding detection of distributed generations

被引:24
作者
Muda, Harikrishna [1 ]
Jena, Premalata [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Roorkee 247667, Uttar Pradesh, India
关键词
principal component analysis; distributed power generation; power distribution faults; fault diagnosis; power generation faults; digital simulation; synchronous generators; asynchronous generators; wind power plants; photovoltaic power systems; battery storage plants; reactive power; phase angle-based PC technique; islanding detection; distributed generation; phase angle-based principal component technique; DG terminal; nonIS; NIS; real-time digital simulator; IEEE 13-bus microgrids; synchronous generator; doubly fed induction wind generator; photovoltaic system; battery energy storage systems; reactive power mismatch; active power mismatch; nondetection zone problem; DG tripping; feeder disconnection; inception point; SYSTEM; MICROGRIDS;
D O I
10.1049/iet-rpg.2017.0089
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The phase angle-based principal component (PC) technique for islanding detection of distributed generations (DGs) is proposed. The phase angle between the positive-sequence components of voltage and current is derived at the DG terminal and used as an input feature vector for the PC technique to identify the islanding situation (IS). The change in phase angle is prominent for both ISs and non-ISs (NISs). By exploiting this change in phase angle, PCs are computed to discriminate between ISs and NISs. The proposed technique is evaluated using data simulated with a real-time digital simulator for IEEE 13-bus microgrids. Critical issues such as a perfect power match IS, different scenarios of microgrids having a synchronous generator, doubly fed induction wind generator, photovoltaic with various control strategies and battery energy storage systems are addressed during performance evaluation of the proposed technique. It is found that the technique identifies the IS under low active and reactive power mismatches and hence overcomes the non-detection zone problem. All NISs such as the fault type, DG tripping and feeder disconnection in the presence of multiple DGs are considered. It is noteworthy to mention that the proposed technique discriminates ISs and NISs within a cycle from the inception point.
引用
收藏
页码:735 / 746
页数:12
相关论文
共 31 条
  • [1] Islanding Detection for Inverter-Based DG Coupled With Frequency-Dependent Static Loads
    Alaboudy, Ali H. Kasem
    Zeineldin, H. H.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (02) : 1053 - 1063
  • [2] [Anonymous], CUTAN OCUL TOXICOL
  • [3] [Anonymous], 2010, 2010 63 ANN C PROTEC, DOI DOI 10.1109/CPRE.2010.5469490
  • [4] [Anonymous], 2014, IEEE Std 1687-2014, DOI [DOI 10.1109/IEEESTD.2014.6804630, 10.1109/IEEESTD.2014.6755433, DOI 10.1109/IEEESTD.2014.6837414]
  • [5] [Anonymous], 2011, IEEE Std 1676-2010, DOI DOI 10.1109/IEEESTD.2011.5960751
  • [6] Dynamic phasor and frequency estimation of time-varying power system signals
    Dash, P. K.
    Krishnanand, K. R.
    Patnaik, R. K.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 44 (01) : 971 - 980
  • [7] A hybrid time-frequency approach based fuzzy logic system for power island detection in grid connected distributed generation
    Dash, P. K.
    Padhee, Malhar
    Panigrahi, T. K.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 453 - 464
  • [8] A Universal Islanding Detection Technique for Distributed Generation Using Pattern Recognition
    Faqhruldin, Omar N.
    El-Saadany, Ehab F.
    Zeineldin, Hatem H.
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (04) : 1985 - 1992
  • [9] A Novel Hybrid Islanding Detection Technique Using Rate of Voltage Change and Capacitor Tap Switching
    Garmrudi, M.
    Nafisi, H.
    Fereidouni, A.
    Hashemi, H.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2012, 40 (10) : 1149 - 1159
  • [10] IEA, T5092002 IEA PVPS