Transfemoral interfaces with vacuum assisted suspension comparison of gait, balance, and subjective analysis: Ischial containment versus brimless

被引:30
作者
Kahle, Jason T. [1 ]
Highsmith, M. Jason [1 ]
机构
[1] Univ S Florida, Tampa, FL 33612 USA
关键词
Amputee; Biomechanics; Prosthetic; Prosthesis evaluation questionnaire; Socket; SOCKET; VALIDITY; AMPUTEES; RELIABILITY; PRESSURES; FIT;
D O I
10.1016/j.gaitpost.2014.04.206
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objective: Investigate the effect of a brimless interface design compared with ischial ramus containment (IRC) of interfaces when using vacuum-assisted suspension (VAS) on transfemoral amputees (TFAs). Design: Randomized experimental crossover. Setting: Household, community, and clinic. Participants: Unilateral TFAs (N = 12 enrolled, N = 10 analyzed). Mean age: 42.9 years. Mean residual limb length: 60.3% of the sound side femur length. Participants' mean time as an amputee: 8.3 years and median AMP score: 43. Interventions: (1) IRC VAS interface, and (2) brimless VAS interface. Average medial wall height for IRC interfaces was 0.7 cm proximal to the distal-most aspect of the ischial tuberosity (IT). The medial wall on the brimless design was an average of 3.3 cm distal to the distal-most aspect of the IT. Main outcome measures: Spatiotemporal gait parameters, limits of stability, four square step test, and subjective perception using the prosthetic evaluation questionnaire (PEQ). Results: Step length was significantly improved towards the IRC (p = 0.04), when calculating degree of asymmetry. Base of support was significantly narrowed toward the brimless (p = 0.03). All subjective measures reached statistical significance in favor of improvement with the brimless design, compared to the IRC. Conclusions: The brimless design was equivalent to IRC in most gait and balance outcome measures. However, step length was more symmetrical toward the IRC while base of support was narrowed toward the brimless demonstrating mixed inconsistent performance changes. Further, the PEQ demonstrated significant subjective improvements in prosthetic related function and quality of life when participants used the brimless design. Brimless interface design may be a clinically viable choice. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 32 条
[1]  
Beil TL, 2002, J REHABIL RES DEV, V39, P693
[2]   Concurrent related validity of the GAITRite® walkway system for quantification of the spatial and temporal parameters of gait [J].
Bilney, B ;
Morris, M ;
Webster, K .
GAIT & POSTURE, 2003, 17 (01) :68-74
[3]   A comparison of trans-tibial amputee suction and vacuum socket conditions [J].
Board, WJ ;
Street, GM ;
Caspers, C .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2001, 25 (03) :202-209
[4]  
Bowker J.H., 2002, Atlas of Limb Prosthetics: Surgical, Prosthetic, and Rehabilitation Principles, V3rd
[5]   Clinical identification of multiple fall risk early after unilateral transtibial amputation [J].
Dite, Wayne ;
Connor, Helen J. ;
Curtis, Heather C. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (01) :109-114
[6]  
FLANDRY F, 1989, CLIN ORTHOP RELAT R, P249
[7]   The Amputee Mobility Predictor: An instrument to assess determinants of the lower-limb amputee's ability to ambulate [J].
Gailey, RS ;
Roach, KE ;
Applegate, EB ;
Cho, B ;
Cunniffe, B ;
Licht, S ;
Maguire, M ;
Nash, MS .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (05) :613-627
[8]  
GAILEY RS, 1993, PROSTHET ORTHOT INT, V17, P95
[9]   Dynamic posturography in evaluation of balance in patients of Parkinson's disease with normal pull test Concept of a diagonal pull test [J].
Ganesan, Mohan ;
Pal, Pramod Kumar ;
Gupta, Anupam ;
Sathyaprabha, Talakad N. .
PARKINSONISM & RELATED DISORDERS, 2010, 16 (09) :595-599
[10]   DOES SOCKET CONFIGURATION INFLUENCE THE POSITION OF THE FEMUR IN ABOVE-KNEE AMPUTATION [J].
GOTTSCHALK, FA ;
KOUROSH, S ;
STILLS, M ;
MCCLELLAN, B ;
ROBERTS, J .
JOURNAL OF PROSTHETICS AND ORTHOTICS, 1989, 2 (01) :94-102