Evaluation of atrial conduction time at various sites of right atrial pacing and influence on atrioventricular delay optimization by surface electrocardiography

被引:14
作者
Strohmer, B
Pichler, M
Froemmel, M
Migschitz, M
Hintringer, F
机构
[1] Landesklin Salzburg, Div Cardiol, A-5020 Salzburg, Austria
[2] Krankenhaus Barmherzigen Schwestern Wien, Dept Med, Vienna, Austria
[3] Univ Innsbruck Hosp, Dept Cardiol, Innsbruck, Austria
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2004年 / 27卷 / 04期
关键词
atrioventricular delay; ECG; atrial conduction time; atrial pacing; echocardiography; stroke volume;
D O I
10.1111/j.1540-8159.2004.00465.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
STROHMER, B., ET AL.: Evaluation of Atrial Conduction Time at Various Sites of Right Atrial Pacing and Influence on Atrioventricular Delay Optimization by Surface Electrocardiography. Cardiac function and electrical stability may be improved by programming of optimal AV delay in DDD pacing. This study tested the hypothesis if the global atrial conduction time at various pacing sites can be derived from the surface ECG to achieve an optimal electromechanical timing of the left heart. Data were obtained from 60 patients following dual chamber pacemaker implantation. Right atrial septal pacing was associated with significantly shorter atrial conduction time (P < 0.0005) and P wave duration (P < 0,005), compared to standard right atrial pacing sites at the right atrial appendage or at the right free wall. The last two pacing sites showed no significant difference. In a group of 31 patients with AV block, optimal AV delay was achieved by programming a delay of 100 ms from the end of the paced P wave to peok/nadir of the paced ventricular complex. Optimization of AV delay resulted in a relative increase of echocardiographic stroke volume (SV) (10.9 +/- 13.7%; 95% Cl: 5.9-15.9%) when compared to nominal AV delay (170 ms). Optimized AV delay was highly variable (range 130-250 ms; mean 180 +/- 35 ms). The hemodynamic response was characterized by a weak significant relationship between SV increase and optimized AV delay (R (2) = 0.196, R = 0.443, P = 0.047). The study validated that septal pacing is advantageous for atrial synchronization compared to conventional right atrial pacing. Tailoring the AV delay with respect to the surfuce EGG improved systolic function significantly and was superior to nominal AV delay settings in the majority of patients.
引用
收藏
页码:468 / 474
页数:7
相关论文
共 27 条
[1]   INTERATRIAL CONDUCTION DURING CARDIAC PACING [J].
AUSUBEL, K ;
KLEMENTOWICZ, P ;
FURMAN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :1026-1031
[2]   Atrial activation analysis by surface P wave and multipolar esophageal recording after cardioversion of persistent atrial fibrillation [J].
Bagliani, G ;
Michelucci, A ;
Angeli, F ;
Meniconi, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (05) :1178-1188
[3]   Prevention of chronic atrial fibrillation by pacing in the region of Bachmann's bundle: Results of a multicenter randomized trial [J].
Bailin, SJ ;
Adler, S ;
Giudici, M .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (08) :912-917
[4]   The electromechanical effects of pacing at different sites within the right atrium [J].
Belham, MRD ;
Gill, J ;
Gammage, MD ;
Holt, PM .
EUROPACE, 2002, 4 (04) :431-437
[5]   Comparison of the acute effects of pacing the atrial septum, right atrial appendage, coronary sinus os, and the latter two sites simultaneously on the duration of atrial activation [J].
Bennett, DH .
HEART, 2000, 84 (02) :193-196
[6]   INTERATRIAL CONDUCTION IN PATIENTS UNDERGOING AV STIMULATION - EFFECTS OF INCREASING RIGHT ATRIAL STIMULATION RATE [J].
CAMOUS, JP ;
RAYBAUD, F ;
DOLISI, C ;
SCHENOWITZ, A ;
VARENNE, A ;
BAUDOUY, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (11) :2082-2086
[7]  
CHIRIFE R, 1998, RECENT ADV CARDIAC P, V4
[8]   Cardiac output-based versus empirically programmed AV interval - how different are they? [J].
Crystal, E ;
Ovsyshcher, IE .
EUROPACE, 1999, 1 (02) :121-125
[9]   A comparison of quality-of-life in patients with dual chamber pacemakers and individually programmed atrioventricular delays [J].
Frielingsdorf, J ;
Deseo, T ;
Gerber, AE ;
Bertel, O .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (08) :1147-1154
[10]   Global P wave duration on the 65-lead ECG: Single-site and dual-site pacing in the structurally normal human atrium [J].
Gozolits, S ;
Fischer, G ;
Berger, T ;
Hanser, F ;
Abou-Harb, M ;
Tilg, B ;
Pachinger, O ;
Hintringer, F ;
Roithinger, FX .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (12) :1240-1245