Effects of coordinate-system construction methods on postoperative computed tomography evaluation of implant orientation after total hip arthroplasty

被引:10
作者
Kyo, Takayuki [1 ]
Nakahara, Ichiro [1 ]
Kuroda, Yasuo [1 ]
Miki, Hidenobu [1 ]
机构
[1] Osaka Natl Hosp, Dept Orthoped Surg, Osaka 5400006, Japan
关键词
Cup anteversion; cup inclination; femoral anteversion; femoral coordinate system; measurement accuracy; pelvic coordinate system; total hip arthroplasty; ASSISTED ORTHOPEDIC-SURGERY; ACETABULAR CUP; NAVIGATION; ACCURACY; IMPINGEMENT; POSITION; BEARING;
D O I
10.3109/10929088.2015.1076047
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: In total hip arthroplasty, it is important to assess postoperative implant orientation. The computed tomography-based (CT-based) three-dimensional (3D) templating method using 3D preoperative planning software is generally recommended. In this method, postoperative implant orientation within a bony coordinate system can be measured by overlaying a 3D computerized model of the implant on a real postoperative CT image of the implant. The bony coordinate system consists of several reference points (RPs) marked on a CT image of the bone surface. Therefore, preoperative and postoperative coordinate systems do not always match. We investigated how the difference between coordinate systems constructed from RPs chosen by manual methods (M1 and M2) and those constructed by the computer matching method influences the results of measurement validation.Methods: In M1, postoperative RPs were chosen without a specific tool in a single planning module. In M2, postoperative RPs were chosen with as little deviation as possible from preoperative RPs, verifying preoperative RPs on another monitor.Results: M1 and M2 produced mean errors in acetabular cup inclination of 0.7 degrees +/- 0.5 degrees and 0.5 degrees +/- 0.3 degrees, respectively, and mean errors in cup anteversion of 1.3 degrees +/- 1.2 degrees and 0.5 degrees +/- 0.4 degrees, respectively, which were statistically significant differences. M1 and M2 produced mean errors in femoral stem anteversion of 2.4 degrees +/- 2.0 degrees and 2.7 degrees +/- 2.1 degrees, respectively, not a significant difference, but these errors were larger than errors in cup orientation.Discussion: We recommend referring to preoperative RPs when choosing postoperative RPs. Surgeons must be aware that for evaluation of postoperative stem anteversion, manual methods may produce considerable error.
引用
收藏
页码:52 / 60
页数:9
相关论文
共 30 条
[1]   Differences between the wear couples metal-on-polyethylene and ceramic-on-ceramic in the stability against dislocation of total hip replacement [J].
Bader, R ;
Steinhauser, E ;
Zimmermann, S ;
Mittelmeier, W ;
Scholz, R ;
Busch, R .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2004, 15 (06) :711-718
[2]  
Barrack Robert L, 2003, J Am Acad Orthop Surg, V11, P89
[3]   Clinical Validation of Computer-Assisted Navigation in Total Hip Arthroplasty [J].
Beaumont, Eric ;
Beaumont, Pierre ;
Odermat, Daniel ;
Fontaine, Isabelle ;
Jansen, Herbert ;
Prince, Francois .
ADVANCES IN ORTHOPEDICS, 2011, 2011
[4]  
DiGioia A M, 1998, Clin Orthop Relat Res, P8
[5]  
Fukunishi S, 2008, ORTHOPEDICS, V31, P987
[6]  
Gambera Dario, 2002, Acta Biomed, V73, P85
[7]   CT Outperforms Radiography for Determination of Acetabular Cup Version after THA [J].
Ghelman, Bernard ;
Kepler, Christopher K. ;
Lyman, Stephen ;
Della Valle, Alejandro Gonzalez .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) :2362-2370
[8]   Optimal acetabular orientation for hip resurfacing [J].
Grammatopoulos, G. ;
Pandit, H. ;
Glyn-Jones, S. ;
McLardy-Smith, P. ;
Gundle, R. ;
Whitwell, D. ;
Gill, H. S. ;
Murray, D. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08) :1072-1078
[9]   Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement [J].
Hananouchi, Takehito ;
Saito, Masanobu ;
Koyama, Tsuyoshi ;
Sugano, Nobuhiko ;
Yoshikawa, Hideki .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (04) :1088-1095
[10]   Ultrasound-based Navigation and 3D CT Compared in Acetabular Cup Position [J].
Hasart, Olaf ;
Poepplau, Berry M. ;
Asbach, Patrick ;
Perka, Carsten ;
Wassilew, Georgi I. .
ORTHOPEDICS, 2009, 32 (10) :6-10