A novel method based on 220Rn (thoron) exhalation rate of indoor surfaces for robust estimates of 220Rn concentration and equilibrium factor to compute inhalation dose

被引:6
作者
Kanse, S. D. [1 ,2 ]
Sahoo, B. K. [1 ]
Gaware, J. J. [1 ]
Sapra, B. K. [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Mumbai 400094, Maharashtra, India
[2] Homi Bhabha Natl Inst, Mumbai 400094, Maharashtra, India
关键词
Thoron; Indoor exposure; Exhalation rate; Wall mounting accumulator; Equilibrium factor; Inhalation dose; PROGENY CONCENTRATIONS; SPATIAL-DISTRIBUTION; RADON CONCENTRATIONS; RADIATION AREAS; DECAY PRODUCTS; DWELLINGS; EXPOSURE; AIR; REGION; UTTARAKHAND;
D O I
10.1016/j.chemosphere.2020.128908
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The research into Rn-220 (thoron) has generated an increasing interest in recent times due to the realisation of its radiological importance in many indoor environments. Though it is assumed that the contribution of Rn-220, per se, to the inhalation dose is negligible in comparison with that of its decay products, this may not be always true. Correct estimation of inhalation dose due to thoron requires a reliable method to measure the concentration of both 220 Rn and its decay products in indoor air. However, due to its very short half-life (55.6 s) Rn-220 shows large variation in its indoor activity concentration. This makes it difficult to have a robust value of Rn-220 concentration which can be considered representative of a house, thus making the dose estimation unreliable. This issue has been addressed in the present study by developing a novel method that utilises the Rn-220 exhalation rate from indoor surfaces as the basis for estimation of average Rn-220 concentration in indoor air. The Rn-220 concentration estimated in this manner can be converted to decay products concentration using a suitable equilibrium factor and finally the inhalation dose using appropriate dose conversion factors. A wall mounting accumulator setup has been developed for easy in-situ measurement of Rn-220 exhalation from room surfaces. The method has been validated through comprehensive measurements in 25 dwellings in two different regions of India. The developed method is very good for large scale field surveys because of fast and easy applicability. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 58 条
[51]   Why is 220Rn (thoron) measurement important? [J].
Tokonami, S. .
RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) :335-339
[52]   The HMGU thoron experimental house: a new tool for exposure assessment [J].
Tschiersch, J. ;
Meisenberg, O. .
RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) :395-399
[53]  
UNSCEAR, 2009, EFF ION RAD UNSCEAR, VII, DOI [10.1007/s10661-009-0863-3, DOI 10.1007/S10661-009-0863-3]
[54]  
UNSCEAR, 2006, REP GEN ASS
[55]  
UNSCEAR (United Nations Scientific Committee on the Effect of Atomic Radiation), 2000, Report to General Assembly, Annex B Exposure from Natural Radiation Sources
[56]   CONTRIBUTION OF THORON AND PROGENY TOWARDS INHALATION DOSE IN A THORIUM ABUNDANT BEACH ENVIRONMENT [J].
Visnuprasad, A. K. ;
Jaikrishnan, G. ;
Sahoo, B. K. ;
Pereira, C. E. ;
Jojo, P. J. .
RADIATION PROTECTION DOSIMETRY, 2018, 178 (04) :405-413
[57]   Radon-thoron discriminative measurements in Gansu province, China, and their implication for dose estimates [J].
Yamada, Y ;
Sun, QF ;
Tokonami, S ;
Akiba, S ;
Zhou, WH ;
Hou, CS ;
Zhang, SZ ;
Ishikawa, T ;
Furukawa, M ;
Fukutsu, K ;
Yonehara, H .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2006, 69 (7-8) :723-734
[58]  
Zhuo W., 2000, J. Health Phys, V35, P365, DOI [10.5453/jhps.35.365, DOI 10.5453/JHPS.35.365]