Routine detection and quantification of hepatitis B virus DNA in clinical laboratories:: performance of three commercial assays

被引:67
作者
Pawlotsky, JM
Bastie, A
Hézode, C
Lonjon, I
Darthuy, F
Rémiré, J
Dhumeaux, D
机构
[1] Univ Paris 12, Hop Henri Mondor, Dept Bacteriol & Virol, F-94010 Creteil, France
[2] Hop Henri Mondor, INSERM, U99, F-94010 Creteil, France
[3] Univ Paris 12, Hop Henri Mondor, Dept Gastroenterol & Hepatol, F-94010 Creteil, France
关键词
hepatitis B virus; viral load; liquid-phase hybridization; branched DNA assay; polymerase chain reaction;
D O I
10.1016/S0166-0934(99)00149-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The detection and quantification of hepatitis B virus (HBV) genomes in molecular biology-based assays appear to be the most reliable methods for monitoring HBV infection and assessing responses to antiviral treatment. The aim of this study was to evaluate the performance of three HBV-DNA detection and quantification assays currently used for the management of HBV-infected patients: a solution-hybridization assay based on hybrid-capture (Digene Hybrid-Capture(TM), Murex Diagnostics, Dartford, UK); a signal-amplification assay based on 'branched-DNA' (bDNA) technology (Quantiplex(TM) HBV DNA, Bayer Diagnostics, Emeryville, CA); and a target-amplification assay based on competitive polymerase chain reaction (Amplicor HBV Monitor(TM), Roche Molecular Systems, Pleasanton, CA). The Monitor assay was significantly more sensitive than both the hybrid-capture and bDNA methods. This better sensitivity appeared to be clinically relevant. The linear ranges of quantification in the hybrid-capture, bDNA and Monitor methods were 6.5-9 log(10) genome copies/ml, 6.5-9.5 log(10) genome equivalents/ml, and 3-5.5 log(10) genome copies/ml, respectively; However, the HBV-DNA units used in the three assays were not comparable. The specificity of the hybrid-capture, bDNA and Monitor assays was 99.2% (95% confidence interval: 97.7-100.0%), 99.2% (97.7-100.0%), and 97.8% (95.3-100%), respectively. Their within-run coefficients of variation and log,, SDs were 5.5% ( +/- 0.025 log(10) copies/ml), 6.7% (+/-0.029 log(10) Eq/ml) and 21.0% (+/- 0.093 log(10) copies/ml), respectively. Between-run coefficients of variation ranged from 4.4-39.1%, 5-39.5%, and 17.8-96.1%, respectively. The competitive PCR-based Monitor assay appears to be significantly more sensitive but slightly less specific and reproducible than the hybrid-capture and bDNA methods. Given their respective performance, these three assays should be used in complementary fashion in the management of HBV-infected patients. (C) 2000 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:11 / 21
页数:11
相关论文
共 21 条
  • [1] CARMAN WF, 1989, LANCET, V2, P588
  • [2] Clinical evaluation and applications of the Amplicor HBV Monitor™ test, a quantitative HBV DNA PCR assay
    Gerken, G
    Gomes, J
    Lampertico, P
    Colombo, M
    Rothaar, T
    Trippler, M
    Colucci, G
    [J]. JOURNAL OF VIROLOGICAL METHODS, 1998, 74 (02) : 155 - 165
  • [3] A novel method for real time quantitative RT PCR
    Gibson, UEM
    Heid, CA
    Williams, PM
    [J]. GENOME RESEARCH, 1996, 6 (10): : 995 - 1001
  • [4] Comparison of plasma virus loads among individuals infected with hepatitis C virus (HCV) genotypes 1, 2, and 3 by Quantiplex HCV RNA assay versions 1 and 2, Roche monitor assay, and an in-house limiting dilution method
    Hawkins, A
    Davidson, F
    Simmonds, P
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (01) : 187 - 192
  • [5] HENDRICKS DA, 1995, AM J CLIN PATHOL, V104, P537
  • [6] CHRONIC TYPE-B HEPATITIS AND THE HEALTHY HBSAG CARRIER STATE
    HOOFNAGLE, JH
    SHAFRITZ, DA
    POPPER, H
    [J]. HEPATOLOGY, 1987, 7 (04) : 758 - 763
  • [7] KANEKO S, 1990, GASTROENTEROLOGY, V99, P799
  • [8] Quantitative detection of hepatitis B virus DNA with a new PCR assay
    Kessler, HH
    Pierer, K
    Santner, BI
    Vellimedu, SK
    Stelzl, E
    Lackner, H
    Moser, A
    Marth, E
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (08) : 601 - 604
  • [9] QUANTITATION OF HEPATITIS-B VIRAL-DNA BY SOLUTION HYBRIDIZATION - COMPARISON WITH DNA-POLYMERASE AND HEPATITIS-B E-ANTIGEN DURING ANTIVIRAL THERAPY
    KUHNS, MC
    MCNAMARA, AL
    PERRILLO, RP
    CABAL, CM
    CAMPBELL, CR
    [J]. JOURNAL OF MEDICAL VIROLOGY, 1989, 27 (04) : 274 - 281
  • [10] LAU JYN, 1993, LANCET, V342, P1335