Manufacture of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) hydrogel tubes for use as nerve guidance channels

被引:173
作者
Dalton, PD
Flynn, L
Shoichet, MS
机构
[1] Univ Toronto, Dept Chem Engn & Appl Chem, Toronto, ON M5S 3E5, Canada
[2] Univ Toronto, Dept Chem, Toronto, ON M5S 1A1, Canada
[3] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M5S 3G9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
2-hydroxyethyl methacrylate; phase separation; tubes; liquid-liquid centrifugal casting; nerve regeneration; pHEMA; HEMA;
D O I
10.1016/S0142-9612(02)00120-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hydrogel tubes of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (p(HEMA-co-MMA)) made by liquid-liquid centrifugal casting are being investigated as potential nerve guidance channels in the central nervous system. An important criterion for the nerve guidance channel is that its mechanical properties are similar to those of the spinal cord, where it will be implanted. The formulated p(HEMA-co-MMA) tubes are soft and flexible, consisting of a gel-like outer layer, and an interconnected macroporous, inner layer. The relative thickness of the gel phase to macroporous phase is controlled by the formulation chemistry, and specifically by the ratio of co-monomers, HEMA and MMA. By varying the surface chemistry of the mold within which the tubes are synthesized, tubes were prepared with either a "cracked" or a smooth outer morphology. Tubes with the cracked outer morphology had periodic channels that traversed the wall of the tube, which resulted in a lower modulus than smooth outer morphology tubes, yet likely greater diffusive permeability. For tubes (and not rods) to be formed, phase separation must precede gelation as is detailed in a formulation phase diagram for HEMA, MMA and water. The tensile elastic modulus of p(HEMA-co-MMA) tubes reflected the formulation chemistry, with greater moduli (up to 400 kPa) recorded for tubes having 10 wt% MMA. The p(HEMA-co-MMA) tubes therefore had similar mechanical properties to those of the spinal cord, which has a reported elastic modulus range between 200 and 600 kPa. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3843 / 3851
页数:9
相关论文
共 41 条
[1]   Neurotrophins BDNF and NT-3 promote axonal re-entry into the distal host spinal cord through Schwann cell-seeded mini-channels [J].
Bamber, NI ;
Li, HY ;
Lu, XB ;
Oudega, M ;
Aebischer, P ;
Xu, XM .
EUROPEAN JOURNAL OF NEUROSCIENCE, 2001, 13 (02) :257-268
[2]   Nerve growth factor- and neurotrophin-3-releasing guidance channels promote regeneration of the transected rat dorsal root [J].
Bloch, J ;
Fine, EG ;
Bouche, N ;
Zurn, AD ;
Aebischer, P .
EXPERIMENTAL NEUROLOGY, 2001, 172 (02) :425-432
[3]   Collagen-GAG substrate enhances the quality of nerve regeneration through collagen tubes up to level of autograft [J].
Chamberlain, LJ ;
Yannas, IV ;
Hsu, HP ;
Strichartz, G ;
Spector, M .
EXPERIMENTAL NEUROLOGY, 1998, 154 (02) :315-329
[4]   AN INVIVO MEASUREMENT AND ANALYSIS OF VISCOELASTIC PROPERTIES OF THE SPINAL-CORD OF CATS [J].
CHANG, GL ;
HUNG, TK ;
FENG, WW .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (02) :115-122
[5]   HYDROPHILIC SPONGES BASED ON 2-HYDROXYETHYL METHACRYLATE .1. EFFECT OF MONOMER MIXTURE COMPOSITION ON THE PORE-SIZE [J].
CHIRILA, TV ;
CHEN, YC ;
GRIFFIN, BJ ;
CONSTABLE, IJ .
POLYMER INTERNATIONAL, 1993, 32 (03) :221-232
[6]   POLY(2-HYDROXYETHYL METHACRYLATE) SPONGES AS IMPLANT MATERIALS - INVIVO AND INVITRO EVALUATION OF CELLULAR INVASION [J].
CHIRILA, TV ;
CONSTABLE, IJ ;
CRAWFORD, GJ ;
VIJAYASEKARAN, S ;
THOMPSON, DE ;
CHEN, YC ;
FLETCHER, WA ;
GRIFFIN, BJ .
BIOMATERIALS, 1993, 14 (01) :26-38
[7]   An overview of the development of artificial corneas with porous skirts and the use of PHEMA for such an application [J].
Chirila, TV .
BIOMATERIALS, 2001, 22 (24) :3311-3317
[8]  
Chirila TV, 1998, CELL POLYM, V17, P141
[9]  
Clayton AB, 1997, POLYM INT, V42, P45, DOI 10.1002/(SICI)1097-0126(199701)42:1<45::AID-PI658>3.0.CO
[10]  
2-W