Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia

被引:60
作者
Liu, Jiewei [1 ]
Wang, Li [3 ]
Chai, Feiyan [1 ]
Han, Yu [1 ]
Qian, Suqin [2 ]
Koch, Douglas D. [3 ]
Weikert, Mitchell P. [3 ]
机构
[1] Shanxi Eye Hosp, Taiyuan, Shanxi, Peoples R China
[2] Changsha Vigor Pediat, Changsha, Hunan, Peoples R China
[3] Baylor Coll Med, Cullen Eye Inst, Houston, TX 77030 USA
关键词
BIOMETRY; ACCURACY;
D O I
10.1016/j.jcrs.2019.01.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the accuracy of intraocular lens (IOL) power calculation formulas in Chinese eyes with axial lengths (ALs) longer than 26.0 mm. Setting: Department of Cataract Surgery, Shanxi Eye Hospital, China. Design: Prospective case series. Methods: This study evaluated (1) two new formulas (Barrett Universal II and Hill-RBF 2.0), (2) three vergence formulas (Haigis, Holladay 1, and SRK/T), and (3) the original and modified Wang-Koch AL adjustment formulas with Holladay 1 and SRK/T. The User Group for Laser interference Biometry lens constants were used for IOL power calculation. The refractive prediction error was calculated by subtracting the predicted refraction from the actual refraction postoperatively. The mean numerical error (MNE), percentage of eyes with hyperopic outcomes, and mean absolute error (MAE) were determined. Results: The study comprised 136 eyes. The Barrett and Hill-RBF formulas had MNEs close to zero (-0.09 D to 0.03 D), the Haigis, Holladay 1, and SRK/T produced hyperopic MNEs (0.25 to 0.70 D), and the original and modified Wang-Koch AL adjustment formulas induced myopic MNEs (-0.48 to -0.22 D). The original Wang-Koch formulas produced significantly lower percentages of eyes with hyperopic outcomes (15% to 18%) than all other formulas (28% to 91%). There were no significant differences in MAEs between the Barrett, Hill-RBF, Haigis, and original and modified Wang-Koch adjustment with the Holladay 1 (0.32 to 0.41 D). Conclusion: The performances of the Barrett and Hill-RBF were comparable in long eyes. The incidence of hyperopic outcome with the Wang-Koch AL adjustment formula was significantly lower than other formulas. (C) 2019 Published by Elsevier Inc. on behalf of ASCRS and ESCRS
引用
收藏
页码:725 / 731
页数:7
相关论文
共 50 条
  • [41] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [42] Accuracy of Intraocular Lens Calculations Using the IOLMaster in Eyes with Long Axial Length and a Comparison of Various Formulas
    Bang, Stacy
    Edell, Erica
    Yu, Qilu
    Pratzer, Kim
    Stark, Walter
    OPHTHALMOLOGY, 2011, 118 (03) : 503 - 506
  • [43] Intraocular lens power calculation formulas accuracy in combined phacovitrectomy: an 8-formulas comparison study
    Hipolito-Fernandes, Diogo
    Luis, Maria Elisa
    Maleita, Diogo
    Gil, Pedro
    Maduro, Vitor
    Costa, Livio
    Marques, Nuno
    Branco, Joao
    Alves, Nuno
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2021, 7 (01)
  • [44] Third- and fourth-generation formulas for intraocular lens power calculation before and after phakic intraocular lens insertion in high myopia
    Amro, Mazen
    Chanbour, Wassef
    Arej, Nicolas
    Jarade, Elias
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (11) : 1321 - 1325
  • [45] Studying the added effect of sum-of-segments biometry to modern intraocular lens power calculation formulas for short eyes
    Helaly, Hany Ahmed
    Elkhawaga, Mohamed Hassan
    El-mansy, Mohamed Sobhy
    Hassan, Mohamed Sobhy
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [46] Effect of Axial Length Adjustment Methods on Intraocular Lens Power Calculation in Highly Myopic Eyes
    Zhang, Jiaqing
    Tan, Xuhua
    Wang, Wei
    Yang, Guangyao
    Xu, Jingmin
    Ruan, Xiaoting
    Gu, Xiaoxun
    Luo, Lixia
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 214 : 110 - 118
  • [47] Intraocular lens power calculation in eyes with a shallow anterior chamber depth and normal axial length
    Lee, Yunjin
    Kim, Mee Kum
    Oh, Joo Youn
    Choi, Hyuk Jin
    Yoon, Chang Ho
    PLOS ONE, 2023, 18 (07):
  • [48] Intraocular lens power calculation for silicone oil-dependent eyes
    Wang, Leyi
    Wang, Xin
    Yang, Xuepeng
    Si, Yuanyuan
    Wu, Jiayin
    Cui, Yan
    FRONTIERS IN MEDICINE, 2023, 10
  • [49] Evaluation of biometric formulas in the calculation of intraocular lens according to axial length and type of the lens
    Sanchez-Linan, Noelia
    Perez-Rueda, Antonio
    Parron-Carreno, Tesifon
    Nievas-Soriano, Bruno-Jose
    Castro-Luna, Gracia
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [50] Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis
    Wang, Qiwei
    Jiang, Wu
    Lin, Tiao
    Zhu, Yi
    Chen, Chuan
    Lin, Haotian
    Chen, Weirong
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (07) : 738 - 749