Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia

被引:60
|
作者
Liu, Jiewei [1 ]
Wang, Li [3 ]
Chai, Feiyan [1 ]
Han, Yu [1 ]
Qian, Suqin [2 ]
Koch, Douglas D. [3 ]
Weikert, Mitchell P. [3 ]
机构
[1] Shanxi Eye Hosp, Taiyuan, Shanxi, Peoples R China
[2] Changsha Vigor Pediat, Changsha, Hunan, Peoples R China
[3] Baylor Coll Med, Cullen Eye Inst, Houston, TX 77030 USA
关键词
BIOMETRY; ACCURACY;
D O I
10.1016/j.jcrs.2019.01.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the accuracy of intraocular lens (IOL) power calculation formulas in Chinese eyes with axial lengths (ALs) longer than 26.0 mm. Setting: Department of Cataract Surgery, Shanxi Eye Hospital, China. Design: Prospective case series. Methods: This study evaluated (1) two new formulas (Barrett Universal II and Hill-RBF 2.0), (2) three vergence formulas (Haigis, Holladay 1, and SRK/T), and (3) the original and modified Wang-Koch AL adjustment formulas with Holladay 1 and SRK/T. The User Group for Laser interference Biometry lens constants were used for IOL power calculation. The refractive prediction error was calculated by subtracting the predicted refraction from the actual refraction postoperatively. The mean numerical error (MNE), percentage of eyes with hyperopic outcomes, and mean absolute error (MAE) were determined. Results: The study comprised 136 eyes. The Barrett and Hill-RBF formulas had MNEs close to zero (-0.09 D to 0.03 D), the Haigis, Holladay 1, and SRK/T produced hyperopic MNEs (0.25 to 0.70 D), and the original and modified Wang-Koch AL adjustment formulas induced myopic MNEs (-0.48 to -0.22 D). The original Wang-Koch formulas produced significantly lower percentages of eyes with hyperopic outcomes (15% to 18%) than all other formulas (28% to 91%). There were no significant differences in MAEs between the Barrett, Hill-RBF, Haigis, and original and modified Wang-Koch adjustment with the Holladay 1 (0.32 to 0.41 D). Conclusion: The performances of the Barrett and Hill-RBF were comparable in long eyes. The incidence of hyperopic outcome with the Wang-Koch AL adjustment formula was significantly lower than other formulas. (C) 2019 Published by Elsevier Inc. on behalf of ASCRS and ESCRS
引用
收藏
页码:725 / 731
页数:7
相关论文
共 50 条
  • [31] Intraocular lens power calculation in short eyes
    Gavin, E. A.
    Hammond, C. J.
    EYE, 2008, 22 (07) : 935 - 938
  • [32] Intraocular Lens Power Calculation in Eyes with Previous Excimer Laser Surgery for Myopia A Report by the American Academy of Ophthalmology
    Pantanelli, Seth M.
    Lin, Charles C.
    Al-Mohtaseb, Zaina
    Rose-Nussbaumer, Jennifer R.
    Santhiago, Marcony R.
    Steigleman, Walter Allan, III
    Schallhorn, Julie M.
    OPHTHALMOLOGY, 2021, 128 (05) : 781 - 792
  • [33] Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes
    Wei, Ling
    Cheng, Kaiwen
    He, Wenwen
    Zhu, Xiangjia
    Lu, Yi
    EYE AND VISION, 2022, 9 (01)
  • [34] Comparison of visual outcomes of a diffractive trifocal intraocular lens and a refractive bifocal intraocular lens in eyes with axial myopia: a prospective cohort study
    Sun, Tong
    Liu, Yiyun
    Gao, Yufei
    Tang, Chuhao
    Lan, Qianqian
    Yang, Tingting
    Zhao, Xiaorui
    Qi, Hong
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [35] A Comprehensive Evaluation of 16 Old and New Intraocular Lens Power Calculation Formulas in Pediatric Eyes
    Achiron, Asaf
    Yahalomi, Tal
    Biran, Amit
    Levinger, Eliya
    Cohen, Eyal
    Elbaz, Uri
    Ali, Asim
    Mireskandari, Kamiar
    Tuuminen, Raimo
    Voytsekhivskyy, Oleksiy V.
    CLINICAL OPHTHALMOLOGY, 2024, 18
  • [36] ACCURACY OF THE NEWER GENERATION INTRAOCULAR-LENS POWER CALCULATION FORMULAS IN LONG AND SHORT EYES
    OLSEN, T
    THIM, K
    CORYDON, L
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (02) : 187 - 193
  • [37] Evaluation of Sum of Segments Biometry in Modern Intraocular Lens Power Calculation Formulas for Long Eyes
    Helaly, Hany Ahmed
    Gaballah, Karim Abdellatif
    Ragab, Ahmed Mahmoud
    Ibrahim, Tamer Moussa
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 785 - 793
  • [38] How to choose the intraocular lens power calculation formulas in eyes with extremely long axial length? A systematic review and meta-analysis
    Li, Xiaoyu
    Wang, Xiaodong
    Liao, Xuan
    PLOS ONE, 2024, 19 (01):
  • [39] Accuracy of New Generation Intraocular Lens Calculation Formulas in Vitrectomized Eyes
    Tan, Xuhua
    Zhang, Jiaqing
    Zhu, Yi
    Xu, Jingmin
    Qiu, Xiaozhang
    Yang, Guangyao
    Liu, Zhenzhen
    Luo, Lixia
    Liu, Yizhi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 217 : 81 - 90
  • [40] Effect of Segmented Optical Axial Length on the Performance of New-Generation Intraocular Lens Power Calculation Formulas in Extremely Long Eyes
    Goto, So
    Maeda, Naoyuki
    Uehara, Kota
    Ogawa, Keiko
    Matsumaru, Maki
    Sugiyama, Saori
    Ohnuma, Kazuhiko
    Lawu, Tjundewo
    Noda, Toru
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (22)