Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia

被引:60
|
作者
Liu, Jiewei [1 ]
Wang, Li [3 ]
Chai, Feiyan [1 ]
Han, Yu [1 ]
Qian, Suqin [2 ]
Koch, Douglas D. [3 ]
Weikert, Mitchell P. [3 ]
机构
[1] Shanxi Eye Hosp, Taiyuan, Shanxi, Peoples R China
[2] Changsha Vigor Pediat, Changsha, Hunan, Peoples R China
[3] Baylor Coll Med, Cullen Eye Inst, Houston, TX 77030 USA
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2019年 / 45卷 / 06期
关键词
BIOMETRY; ACCURACY;
D O I
10.1016/j.jcrs.2019.01.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the accuracy of intraocular lens (IOL) power calculation formulas in Chinese eyes with axial lengths (ALs) longer than 26.0 mm. Setting: Department of Cataract Surgery, Shanxi Eye Hospital, China. Design: Prospective case series. Methods: This study evaluated (1) two new formulas (Barrett Universal II and Hill-RBF 2.0), (2) three vergence formulas (Haigis, Holladay 1, and SRK/T), and (3) the original and modified Wang-Koch AL adjustment formulas with Holladay 1 and SRK/T. The User Group for Laser interference Biometry lens constants were used for IOL power calculation. The refractive prediction error was calculated by subtracting the predicted refraction from the actual refraction postoperatively. The mean numerical error (MNE), percentage of eyes with hyperopic outcomes, and mean absolute error (MAE) were determined. Results: The study comprised 136 eyes. The Barrett and Hill-RBF formulas had MNEs close to zero (-0.09 D to 0.03 D), the Haigis, Holladay 1, and SRK/T produced hyperopic MNEs (0.25 to 0.70 D), and the original and modified Wang-Koch AL adjustment formulas induced myopic MNEs (-0.48 to -0.22 D). The original Wang-Koch formulas produced significantly lower percentages of eyes with hyperopic outcomes (15% to 18%) than all other formulas (28% to 91%). There were no significant differences in MAEs between the Barrett, Hill-RBF, Haigis, and original and modified Wang-Koch adjustment with the Holladay 1 (0.32 to 0.41 D). Conclusion: The performances of the Barrett and Hill-RBF were comparable in long eyes. The incidence of hyperopic outcome with the Wang-Koch AL adjustment formula was significantly lower than other formulas. (C) 2019 Published by Elsevier Inc. on behalf of ASCRS and ESCRS
引用
收藏
页码:725 / 731
页数:7
相关论文
共 50 条
  • [1] Intraocular lens power calculation formulas in Chinese eyes with high axial myopia
    Tsang, CSL
    Chong, GSL
    Yiu, EPF
    Ho, CK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1358 - 1364
  • [2] Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial myopia
    Stopyra, Wiktor
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2023, 13 (02) : 225 - 230
  • [3] Clinical outcomes and comparison of intraocular lens calculation formulas in eyes with long axial myopia
    Ang, Robert Edward T.
    Rapista, Aprille June B.
    Remo, Jocelyn Therese M.
    Tan-Daclan, Melody Ana T.
    Cruz, Emerson M.
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2022, 12 (03) : 305 - 311
  • [4] A Comparison of Intraocular Lens Power Calculation Formulas in High Myopia
    Bernardes, Joao
    Raimundo, Miguel
    Lobo, Conceicao
    Murta, Joaquim Neto
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 207 - +
  • [5] The comparison of the intraocular lens power calculation formulas in long eyes
    Yildiz, Aydin
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (07) : 1173 - 1176
  • [6] Accuracy of new intraocular lens calculation formulas in Chinese eyes with short axial lengths
    Ma, Yueting
    Lin, Yongdong
    Li, Yuancun
    Hu, Zhuoyi
    Qiu, Kunliang
    FRONTIERS IN MEDICINE, 2023, 10
  • [7] Intraocular lens power calculation in eyes with extreme myopia: Comparison of Barrett Universal II, Haigis, and Olsen formulas
    Rong, Xianfang
    He, Wenwen
    Zhu, Qian
    Qian, Dongjin
    Lu, Yi
    Zhu, Xiangjia
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 732 - 737
  • [8] Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial hyperopia
    Stopyra, Wiktor
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [9] Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes
    Liangpin Li
    Liyun Yuan
    Kun Yang
    Yanan Wu
    Simayilijiang Alafati
    Xia Hua
    Yan Wang
    Xiaoyong Yuan
    Scientific Reports, 13 (1)
  • [10] Comparison of the accuracy of 9 intraocular lens power calculation formulas after SMILE in Chinese myopic eyes
    Li, Liangpin
    Yuan, Liyun
    Yang, Kun
    Wu, Yanan
    Alafati, Simayilijiang
    Hua, Xia
    Wang, Yan
    Yuan, Xiaoyong
    SCIENTIFIC REPORTS, 2023, 13 (01):