Fracture behavior of all-ceramic, implant-supported, and tooth-implant-supported fixed dental prostheses

被引:13
作者
Alkharrat, Abdul Rahman [1 ,2 ,3 ]
Schmitter, Marc [2 ]
Rues, Stefan [1 ]
Rammelsberg, Peter [1 ]
机构
[1] Heidelberg Univ, Dept Prosthodont, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Univ Wurzburg, Dept Prosthodont, Pleicherwall 2, D-97070 Wurzburg, Germany
[3] Damascus Univ, Fac Dent, Dept Prosthodont, Damascus, Syria
关键词
Chipping; All-ceramics FDPs; Different loading conditions; Different support types; Fracture resistance; PARTIALLY EDENTULOUS PATIENTS; PARTIAL DENTURES; COMPLICATION RATES; IN-VITRO; CLINICAL-EVALUATION; LITHIUM DISILICATE; OBSERVATION PERIOD; ZIRCONIA; STRENGTH; TEETH;
D O I
10.1007/s00784-017-2233-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives In vitro investigation of the effects of fixed dental prosthesis (FDP) support and loading conditions on the fracture behavior of all-ceramic, zirconia-based FDP veneered with computer-aided design/computer-aided manufacturing (CAD/CAM)-manufactured lithium disilicate ceramic. Materials and methods Based on a model for a 3-unit FDP in the molar region (tooth in region 15, implant in region 17), 16 identical zirconia frameworks were fabricated and veneered with milled lithium disilicate ceramic. Another 16 FDPs were manufactured similarly, using a model in which the tooth was replaced by an implant. The specimens underwent 10,000 thermal cycles between 6.5 and 60 degrees C and 1,200,000 chewing cycles with a force magnitude of 100 N. All were then subsequently loaded until fracture in a universal testing device. Half of the FDPs were subjected to centric and axial loading on the pontic, the others to eccentric and oblique loading on one cusp of the pontic. Results No failures were observed after artificial aging. Fracture loads of tooth-implant-supported restorations were 1636 +/- 158 and 1086 +/- 156 N for axial and oblique loading, respectively; implant-supported FDPs fractured at 1789 +/- 202 and 1200 +/- 68 N, respectively. Differences were significant for load application (P < 0.001) and support type (P = 0.020). For the two types of load application, fracture mode differed substantially: complete fracture was observed for centric and axial loading whereas mixed cohesive/adhesive failure was observed for many FDPs loaded eccentrically and obliquely. Conclusions The high incidence of chipping of manually veneered implant-supported all-ceramics restorations might be reduced by use of CAD/CAM-manufactured lithium disilicate veneers.
引用
收藏
页码:1663 / 1673
页数:11
相关论文
共 34 条
[1]   Bridging the gap between clinical failure and laboratory fracture strength tests using a fractographic approach [J].
Aboushelib, Moustafa N. ;
Feilzer, Albert J. ;
Kleverlaan, Cees J. .
DENTAL MATERIALS, 2009, 25 (03) :383-391
[2]   ZrO2 three-unit fixed partial dentures:: comparison of failure load before and after exposure to a mastication simulator [J].
Att, W. ;
Grigoriadou, M. ;
Strub, J. R. .
JOURNAL OF ORAL REHABILITATION, 2007, 34 (04) :282-290
[3]   High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings - A new fabrication mode for all-ceramic restorations [J].
Beuer, Florian ;
Schweiger, Josef ;
Eichberger, Marlis ;
Kappert, Heinrich F. ;
Gernet, Wolfgang ;
Edelhoff, Daniel .
DENTAL MATERIALS, 2009, 25 (01) :121-128
[4]  
Block MS, 2002, INT J ORAL MAX IMPL, V17, P473
[5]   Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function [J].
Brägger, U ;
Aeschlimann, S ;
Bürgin, W ;
Hämmerle, CHF ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) :26-34
[6]   MECHANICAL CONSIDERATIONS FOR THE IMPLANT TOOTH-SUPPORTED FIXED PARTIAL DENTURE [J].
BREEDING, LC ;
DIXON, DL ;
SADLER, JP ;
MCKAY, ML .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (05) :487-492
[7]   Five-year clinical evaluation of zirconia-based bridges in patients in UK general dental practices [J].
Burke, F. J. T. ;
Crisp, R. J. ;
Cowan, A. J. ;
Lamb, J. ;
Thompson, O. ;
Tulloch, N. .
JOURNAL OF DENTISTRY, 2013, 41 (11) :992-999
[8]  
Buso L, 2011, Minerva Stomatol, V60, P311
[9]   A clinical comparison of zirconia, metal and alumina fixed-prosthesis frameworks veneered with layered or pressed ceramic A three-year report [J].
Christensen, Rella P. ;
Ploeger, Brad J. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (11) :1317-1329
[10]   Laboratory Simulation of Y-TZP All-ceramic Crown Clinical Failures [J].
Coelho, P. G. ;
Bonfante, E. A. ;
Silva, N. R. F. ;
Rekow, E. D. ;
Thompson, V. P. .
JOURNAL OF DENTAL RESEARCH, 2009, 88 (04) :382-386