High-Resolution 3D Proton MRI of Hyperpolarized Gas Enabled by Parahydrogen and Rh/TiO2 Heterogeneous Catalyst

被引:71
作者
Kovtunov, Kirill V. [1 ,2 ]
Barskiy, Danila A. [1 ,2 ]
Coffey, Aaron M. [3 ,4 ]
Truong, Milton L. [3 ,4 ]
Salnikov, Oleg G. [1 ,2 ]
Khudorozhkov, Alexander K. [5 ]
Inozemtseva, Elizaveta A. [5 ]
Prosvirin, Igor P. [5 ]
Bukhtiyarov, Valery I. [5 ]
Waddell, Kevin W. [3 ,4 ]
Chekmenev, Eduard Y. [3 ,4 ]
Koptyug, Igor V. [1 ,2 ]
机构
[1] SB RAS, Lab Magnet Resonance Microimaging, Int Tomog Ctr, 3A Inst Skaya St, Novosibirsk 630090, Russia
[2] Novosibirsk State Univ, Novosibirsk 630090, Russia
[3] Vanderbilt Univ, Med Ctr, Dept Radiol, Inst Imaging Sci,Dept Biomed Engn,Dept Phys & Ast, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Dept Biochem, Nashville, TN 37232 USA
[5] Boreskov Inst Catalysis SB RAS, Novosibirsk 630090, Russia
关键词
heterogeneous catalysis; hyperpolarized gas; magnetic resonance imaging; parahydrogen; supported catalysts; HYDROGEN-INDUCED POLARIZATION; NUCLEAR-POLARIZATION; NMR; FIELD;
D O I
10.1002/chem.201403604
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Several supported metal catalysts were synthesized, characterized, and tested in heterogeneous hydrogenation of propene with parahydrogen to maximize nuclear spin hyperpolarization of propane gas using parahydrogen induced polarization (PHIP). The Rh/TiO2 catalyst with a metal particle size of 1.6 nm was found to be the most active and effective in the pairwise hydrogen addition and robust, demonstrating reproducible results with multiple hydrogenation experiments and stability for >= 1.5 years. 3D H-1 magnetic resonance imaging (MRI) of 1% hyperpolarized flowing gas with microscale spatial resolution (625 x 625 x 625 mu m(3)) and large imaging matrix (128 x 128 x 32) was demonstrated by using a preclinical 4.7 T scanner and 17.4 s imaging scan time.
引用
收藏
页码:11636 / 11639
页数:4
相关论文
共 30 条
  • [1] Dynamic Nuclear Polarization Polarizer for Sterile Use Intent
    Ardenkjaer-Larsen, Jan H.
    Leach, Andrew M.
    Clarke, Neil
    Urbahn, John
    Anderson, Denise
    Skloss, Timothy W.
    [J]. NMR IN BIOMEDICINE, 2011, 24 (08) : 927 - 932
  • [2] Increase in signal-to-noise ratio of >10,000 times in liquid-state NMR
    Ardenkjaer-Larsen, JH
    Fridlund, B
    Gram, A
    Hansson, G
    Hansson, L
    Lerche, MH
    Servin, R
    Thaning, M
    Golman, K
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (18) : 10158 - 10163
  • [3] NMR imaging of catalytic hydrogenation in microreactors with the use of para-hydrogen
    Bouchard, Louis-S.
    Burt, Scott R.
    Anwar, M. Sabieh
    Kovtunov, Kirill V.
    Koptyug, Igor V.
    Pines, Alexander
    [J]. SCIENCE, 2008, 319 (5862) : 442 - 445
  • [4] BOUCHARD LS, 2007, ANGEW CHEM, V119, P4142
  • [5] TRANSFORMATION OF SYMMETRIZATION ORDER TO NUCLEAR-SPIN MAGNETIZATION BY CHEMICAL-REACTION AND NUCLEAR-MAGNETIC-RESONANCE
    BOWERS, CR
    WEITEKAMP, DP
    [J]. PHYSICAL REVIEW LETTERS, 1986, 57 (21) : 2645 - 2648
  • [6] Low-field MRI can be more sensitive than high-field MRI
    Coffey, Aaron M.
    Truong, Milton L.
    Chekmenev, Eduard Y.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2013, 237 : 169 - 174
  • [7] Application of Parahydrogen Induced Polarization Techniques in NMR Spectroscopy and Imaging
    Duckett, Simon B.
    Mewis, Ryan E.
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 2012, 45 (08) : 1247 - 1257
  • [8] PARA HYDROGEN INDUCED POLARIZATION IN HYDROGENATION REACTIONS
    EISENSCHMID, TC
    KIRSS, RU
    DEUTSCH, PP
    HOMMELTOFT, SI
    EISENBERG, R
    BARGON, J
    LAWLER, RG
    BALCH, AL
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1987, 109 (26) : 8089 - 8091
  • [9] A pulsed injection parahydrogen generator and techniques for quantifying enrichment
    Feng, Bibo
    Coffey, Aaron M.
    Colon, Raul D.
    Chekmenev, Eduard Y.
    Waddell, Kevin W.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2012, 214 : 258 - 262
  • [10] Parahydrogen-induced polarization in imaging:: Subsecond 13C angiography
    Golman, K
    Axelsson, O
    Jóhannesson, H
    Månsson, S
    Olofsson, C
    Petersson, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) : 1 - 5