Determination of lovastatin and simvastatin in pharmaceutical dosage forms by MEKC

被引:61
作者
Srinivasu, MK
Raju, AN
Reddy, GO [1 ]
机构
[1] Technol Dev Ctr, Custom Chem Serv, Dr Reddys Labs, Hyderabad 500050, Andhra Pradesh, India
[2] Dr Reddys Res Fdn, Dept Analyt Res, Hyderabad 500050, Andhra Pradesh, India
关键词
lovastatin; simvastatin; MEKC; dosage form; validation; peak purity; RSD;
D O I
10.1016/S0731-7085(02)00128-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A micellar electrokinetic chromatographic (MEKC) method was developed for the quantification of lovastatin and simvastatin, cholesterol lowering agents in pharmaceutical dosage forms. Lovastatin and simvastatin were separated using an electrolyte system consisting of 12% acetonitrile (v/v) in 25 mM sodium borate buffer pH 9.3 containing 25 mM sodium dodecyl sulphate (SDS) with an extended light path capillary (48.5 cm x 50 mum i.d, 40 cm to detector). The method has been validated and proven to be rugged. Calibration curves were linear over the studied ranges with correlation coefficients greater than 0.996. A limit of detection of 3.2 mug/ml and a limit of quantitation of 10.6 mug/ml were estimated for both the drugs. The proposed method was found to be suitable and accurate for the determination of these drugs in commercial formulations. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:715 / 721
页数:7
相关论文
共 7 条
[1]  
BEDELL LS, 1996, PHYSICIANS GENRX COM
[2]   Micellar electrokinetic capillary chromatography as an alternative method for the determination of ethinylestradiol and levo-norgestrel [J].
Berzas, JJ ;
Del Castillo, B ;
Castañeda, G ;
Pinilla, MJ .
TALANTA, 1999, 50 (02) :261-268
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF MEVINOLIN AS MEVINOLINIC ACID IN FERMENTATION BROTHS [J].
FRIEDRICH, J ;
ZUZEK, M ;
BENCINA, M ;
CIMERMAN, A ;
STRANCAR, A ;
RADEZ, I .
JOURNAL OF CHROMATOGRAPHY A, 1995, 704 (02) :363-367
[4]  
IFPMA, 1995, FED REGISTER, V60, P11260
[5]   Determination of simvastatin and its active metabolite in human plasma by column-switching high-performance liquid chromatography with fluorescence detection after derivatization with 1-bromoacetylpyrene [J].
Ochiai, H ;
Uchiyama, N ;
Imagaki, K ;
Hata, S ;
Kamei, T .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 694 (01) :211-217
[6]   APPLICATION AND OPTIMIZATION OF CAPILLARY ZONE ELECTROPHORESIS IN VITAMIN ANALYSIS [J].
SCHIEWE, J ;
MRESTANI, Y ;
NEUBERT, R .
JOURNAL OF CHROMATOGRAPHY A, 1995, 717 (1-2) :255-259
[7]  
*US PHARM CONV IN, 1995, US PHARM, P906