摘要
Purpose: To retrospectively assess the diagnostic performance of the short inversion time inversion-recovery ( STIR) magnetic resonance (MR) sequence for depiction and classification of articular cartilaginous lesions in femorotibial joint, with arthroscopy as reference standard. Materials and Methods: Institutional review board did not require approval and informed consent for review of patients' records or images. All patients ( and parents of underage patients) agreed to use of their data. Two musculoskeletal radiologists independently analyzed femorotibial cartilage on coronal STIR images from 84 knee MR examinations in 83 patients ( 48 male patients [ 49 knees], 35 female patients; mean age, 39.5 years). Slightly modified Outerbridge classification was used: grade 0, normal cartilage; grade 1, softening or swelling; grade 2, partial-thickness defect; grade 3, fissuring to the level of the subchondral bone; and grade 4, exposed subchondral bone. Arthroscopy performed within 15 weeks was the standard of reference. Classification for arthroscopy differed only in definition of grade 1 ( softening or swelling of cartilage). Sensitivity, specificity, accuracy, positive and negative predictive values, and weighted k values were calculated to assess interobserver reliability. Results: At arthroscopy, 212 (63%) of 336 surfaces were classified as grade 0 ( normal); 37 (11%), as grade 1 abnormalities; 30 (9%), as grade 2 lesions; 25 (7%), as grade 3 lesions; and 32 (10%), as grade 4 lesions. Grades 0 and 1 were considered normal; grades 2 - 4, as abnormal. For detection of contour defects of the cartilaginous surface, coronal STIR MR imaging had sensitivity values of 77% and 76%, specificity values of 96% and 89%, accuracy values of 91% and 85%, positive predictive values of 86% and 70%, and negative predictive values of 92% and 91% for readers 1 and 2, respectively. Weighted k value was 0.63. Conclusion: Contour defects of femorotibial cartilage can be detected with reasonable accuracy with routine STIR sequence.
引用
收藏
页码:482 / 488
页数:7
相关论文
共 26 条
  • [1] Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients
    Bredella, MA
    Tirman, PFJ
    Peterfy, CG
    Zarlingo, M
    Feller, JF
    Bost, FW
    Belzer, JP
    Wischer, TK
    Genant, HK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) : 1073 - 1080
  • [2] Observer reliability in the arthroscopic classification of osteoarthritis of the knee
    Brismar, BH
    Wredmark, T
    Movin, T
    Leandersson, J
    Svensson, O
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B : 42 - 47
  • [3] Buckwalter JA, 1998, ARTHRITIS RHEUM-US, V41, P1331, DOI 10.1002/1529-0131(199808)41:8<1331::AID-ART2>3.0.CO
  • [4] 2-J
  • [5] Reproducibility and reliability of the outerbridge classification for grading chondral lesions of the knee arthroscopically
    Cameron, ML
    Briggs, KK
    Steadman, JR
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (01) : 83 - 86
  • [6] DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY
    DISLER, DG
    MCCAULEY, TR
    WIRTH, CR
    FUCHS, MD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 377 - 382
  • [7] Special focus session - What's new in cartilage?
    Gold, GE
    McCauley, TR
    Gray, ML
    Disler, DG
    [J]. RADIOGRAPHICS, 2003, 23 (05) : 1227 - 1242
  • [8] MRI in the diagnosis of cartilage injury in the wrist
    Haims, AH
    Moore, AE
    Schweitzer, ME
    Morrison, WB
    Deely, D
    Culp, RW
    Forman, HP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (05) : 1267 - 1270
  • [9] Comparison of new sequences for high-resolution cartilage imaging
    Hargreaves, BA
    Gold, GE
    Beaulieu, CF
    Vasanawala, SS
    Nishimura, DG
    Pauly, JM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (04) : 700 - 709
  • [10] FAST SPIN-ECHO INVERSION-RECOVERY IMAGING VERSUS FAST T2-WEIGHTED SPIN-ECHO IMAGING IN BONE-MARROW ABNORMALITIES
    HILFIKER, P
    ZANETTI, M
    DEBATIN, JF
    MCKINNON, G
    HODLER, J
    [J]. INVESTIGATIVE RADIOLOGY, 1995, 30 (02) : 110 - 114