Nonaqueous capillary electrophoresis equipped with amperometric detection for analysis of chlorinated phenolic compounds

被引:24
作者
Luong, JHT [1 ]
Hilmi, A [1 ]
Nguyen, AL [1 ]
机构
[1] Natl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H4P 2R2, Canada
关键词
nonaqueous capillary electrophoresis; electrochemical detection; instrumentation; buffer composition; chlorophenols; cyclodextrins;
D O I
10.1016/S0021-9673(99)01032-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nonaqueous capillary electrophoresis (NACE) equipped with amperometric detection has been developed for separation and detection of an 11-member model mixture of chlorinated phenolic compounds. With triacetyl-beta-cyclodextrin (TACD) as a novel selectivity selector, acetonitrile proved to be an excellent solvent for this water-insoluble cyclodextrin derivative. Resolution of the analytes was achieved by using an optimized acetonitrile medium consisting of 500 mM acetic acid, 10 mM sodium acetate, 12 mM TACD and 50 mM tetrabutylammonium perchlorate. Separation of analytes was attributed to differential electrostatic and/or inductive interactions of the analytes with the TACD/TBA(+) complex and charged tetrabutylammonium phases. A simple end-column amperometric detector (Pt vs. Ag/AgCl, poised at +1.6 V) in conjunction with NACE was used to analyze chlorophenols. Amperometric detection of such target compounds in acetonitrile-based media offers high sensitivity and alleviates electrode fouling compared to aqueous buffers. The detection limits obtained, ranging from 30 nM to 500 nM, are 3-8-fold lower than those obtained with aqueous buffers. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:323 / 333
页数:11
相关论文
共 34 条
[1]   CHLORINATED PHENOLS - OCCURRENCE, TOXICITY, METABOLISM, AND ENVIRONMENTAL-IMPACT [J].
AHLBORG, UG ;
THUNBERG, TM .
CRC CRITICAL REVIEWS IN TOXICOLOGY, 1980, 7 (01) :1-35
[2]   SEPARATION OF VERY HYDROPHOBIC COMPOUNDS BY HYDROPHOBIC INTERACTION ELECTROKINETIC CHROMATOGRAPHY [J].
AHUJA, ES ;
FOLEY, JP .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :73-83
[3]   Chiral separation in non-aqueous media by capillary electrophoresis using the ion-pair principle [J].
Bjornsdottir, I ;
Hansen, SH ;
Terabe, S .
JOURNAL OF CHROMATOGRAPHY A, 1996, 745 (1-2) :37-44
[4]   Analyte-additive interactions in nonaqueous capillary electrophoresis: a critical review [J].
Bowser, MT ;
Kranack, AR ;
Chen, DDY .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (07) :424-434
[5]   Integration of separation capillary with a Au film electrode and an etched decoupler in amperometric capillary electrophoresis [J].
Chen, DC ;
Hsieh, RMR ;
Chen, CH .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1998, 45 (02) :257-262
[6]   CAPILLARY ZONE ELECTROPHORESIS IN ORGANIC-SOLVENTS - SEPARATION OF ANIONS IN METHANOLIC BUFFER SOLUTIONS [J].
CHIARI, M ;
KENNDLER, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :303-309
[7]   ANODIC-OXIDATION OF PHENOL FOR WASTE-WATER TREATMENT [J].
COMNINELLIS, C ;
PULGARIN, C .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1991, 21 (08) :703-708
[8]   THE ELECTROCHEMICAL OXIDATION OF AQUEOUS PHENOL AT A GLASSY-CARBON ELECTRODE [J].
GATTRELL, M ;
KIRK, DW .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1990, 68 (06) :997-1003
[9]   A STUDY OF THE OXIDATION OF PHENOL AT PLATINUM AND PREOXIDIZED PLATINUM SURFACES [J].
GATTRELL, M ;
KIRK, DW .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1993, 140 (06) :1534-1540
[10]  
GERHARTS W, 1986, ULLMANNS ENCY IND A, V7, P2