Detection of periapical bone defects in human jaws using cone beam computed tomography and intraoral radiography

被引:162
作者
Patel, S. [1 ]
Dawood, A.
Mannocci, F. [1 ]
Wilson, R. [2 ]
Ford, T. Pitt [1 ]
机构
[1] Kings Coll London, Inst Dent, Endodont Postgrad Unit, London WC2R 2LS, England
[2] Kings Coll London, Inst Dent, Dept Periodontol, London WC2R 2LS, England
关键词
cone beam computed tomography; endodontic diagnosis; periapical lesions; DIGITAL DENTAL RADIOGRAPHY; DIAGNOSTIC-ACCURACY; CONVENTIONAL RADIOGRAPHY; APICAL PERIODONTITIS; ENDODONTIC SUCCESS; CANCELLOUS BONE; IN-VITRO; LESIONS; RELIABILITY; FILM;
D O I
10.1111/j.1365-2591.2008.01538.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To compare the diagnostic accuracy of intraoral digital periapical radiography with that of cone beam computed tomography (CBCT) for the detection of artificial periapical bone defects in dry human jaws. Small and large artificial periapical lesions were prepared in the periapical region of the distal root of six molar teeth in human mandibles. Scans and radiographs were taken with a charged couple device (CCD) digital radiography system and a CBCT scanner before and after each periapical lesion had been created. Sensitivity, specificity, positive predictive values, negative predictive values and Receiver Operator Characteristic (ROC) curves as well as the reproducibility of each technique were determined. The overall sensitivity was 0.248 and 1.0 for intraoral radiography and CBCT respectively, i.e. these techniques correctly identified periapical lesions in 24.8% and 100% of cases, respectively. Both imaging techniques had specificity values of 1.0. The ROC Az values were 0.791 and 1.000 for intraoral radiography and CBCT, respectively. With intraoral radiography, external factors (i.e. anatomical noise and poor irradiation geometry), which are not in the clinician's control, hinder the detection of periapical lesions. CBCT removes these external factors. In addition, it allows the clinician to select the most relevant views of the area of interest resulting in improved detection of the presence and absence of artificial periapical lesions.
引用
收藏
页码:507 / 515
页数:9
相关论文
共 44 条
[1]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[2]   Detectability of artificial periapical lesions using direct digital and conventional radiography [J].
Barbat, J ;
Messer, HH .
JOURNAL OF ENDODONTICS, 1998, 24 (12) :837-842
[3]   ROENTGENOGRAPHIC AND DIRECT OBSERVATION OF EXPERIMENTAL LESIONS IN BONE .1. [J].
BENDER, IB ;
SELTZER, S .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1961, 62 (02) :152-&
[4]  
Bender IB, 1982, J ENDODONT, V23, P5
[5]  
Brynolf I, 1970, Sven Tandlak Tidskr, V63, P415
[6]  
Brynolf I, 1970, Sven Tandlak Tidskr, V63, P409
[7]   Endodontic applications of cone-beam volumetric tomography [J].
Cotton, Taylor P. ;
Geisler, Todd M. ;
Holden, David T. ;
Schwartz, Scott A. ;
Schindler, William G. .
JOURNAL OF ENDODONTICS, 2007, 33 (09) :1121-1132
[8]   Accuracy of cone beam computed tomography and panoramic and periapical radiography for detection of apical periodontitis [J].
Estrela, Carlos ;
Bueno, Mike Reis ;
Leles, Claudio Rodrigues ;
Azevedo, Bruno ;
Azevedo, Jose Ribamar .
JOURNAL OF ENDODONTICS, 2008, 34 (03) :273-279
[9]   A comparison of 18 different x-ray detectors currently used in dentistry [J].
Farman, AG ;
Farman, TT .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 99 (04) :485-489
[10]   ENDODONTIC SUCCESS - WHOS READING RADIOGRAPH [J].
GOLDMAN, M ;
DARZENTA, N ;
PEARSON, AH .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1972, 33 (03) :432-&