Speciation of arsenic and selenium by capillary electrophoresis

被引:34
作者
Sun, BG [1 ]
Macka, M [1 ]
Haddad, PR [1 ]
机构
[1] Univ Tasmania, Sch Chem, Australian Ctr Res Seperat Sci, Hobart, Tas 7001, Australia
关键词
sediment; food analysis; arsenic; selenium; organoarsenic compounds; organoselenium compounds;
D O I
10.1016/j.chroma.2004.03.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary electrophoresis (CE) with direct UV detection, both on-capillary and with a high-sensitivity detection cell (HSDC), were used for the simultaneous determination of arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), selenate [Se(VI)], selenite [Se(TV)], selenocystine (SeC), selenomethionine (SeM) and selenocystamine (SeCM). These anionic and cationic species were separated with negative separation voltage polarity in a capillary coated with poly(diallydimethylammonium chloride) (PDDAC). The background electrolyte (BGE) providing optimal separation was 15 mM phosphate buffer at pH 10.6. Arsenic and selenium species were detected at 195 and 200 nm, respectively. The limit of detection (LOD) values with on-capillary detection (75 mum i.d.) for the individual analytes were 1.02, 1.50, 1.08, 1.35, 19.5, 0.36, 0.32, 1.11 and 1.47 mg/L, respectively (expressed as arsenic or selenium). The method precision for peak area was from 2.1 to 3.4% relative standard deviation. HSDC was applied to increase the detection sensitivity and gave LOD improvement factors from 4.7 to 8.2, yielding LODs for the individual target analytes ranging from 0.049 to 2.38 mg/L. When the normal sample stacking mode was employed using a sample plug up to 4.6% of capillary volume, both the cationic and anionic analytes were stacked simultaneously with LOD improvement factors of 2.6-4.5 yielding LODs for the individual analytes ranging from 0.11 to 7.42 mg/L. The method was applied for the speciation of arsenic in sediment and determination of SeM in a selenium nutrition supplement. The achieved separation selectivity also gives the method a more general application potential for simultaneous arsenic and selenium speciation when hyphenated with inductively coupled plasma MS. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 25 条
  • [1] ANALYSIS OF ORGANIC AND NONORGANIC ARSENIOUS OR SELENIOUS COMPOUNDS BY CAPILLARY ELECTROPHORESIS
    ALBERT, M
    DEMESMAY, C
    ROCCA, JL
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (4-5): : 426 - 432
  • [2] *AUSTR NZ ENV CONS, 1999, AUSTR NZ GUID FRESH, V1
  • [3] Simultaneous speciation of arsenic, selenium, antimony and tellurium species in FT waters and soil extracts by capillary electrophoresis and UV detection
    Casiot, C
    Alonso, MCB
    Boisson, J
    Donard, OFX
    Potin-Gautier, M
    [J]. ANALYST, 1998, 123 (12) : 2887 - 2893
  • [4] DONARD OFX, 1998, ICP INFORM NEWSL, V24, P64
  • [5] Determination of five selenium compounds in urine by liquid chromatography with focused microwave assisted digestion and hydride generation-atomic absorption spectrometric detection
    Gómez, MM
    Gasparic, T
    Palacios, MA
    Camara, C
    [J]. ANALYTICA CHIMICA ACTA, 1998, 374 (2-3) : 241 - 251
  • [6] Johns C, 2003, LC GC EUR, V16, P290
  • [7] KUHN R, 1993, CAPILLARY ELECTROPHO, P239
  • [8] Speciation of key arsenic metabolic intermediates in human urine
    Le, XC
    Lu, XF
    Ma, MS
    Cullen, WR
    Aposhian, HV
    Zheng, BS
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5172 - 5177
  • [9] SPECIATION OF SELENIUM AND ARSENIC COMPOUNDS IN NATURAL-WATERS BY CAPILLARY ZONE ELECTROPHORESIS AFTER ON-COLUMN PRECONCENTRATION WITH FIELD-AMPLIFIED INJECTION
    LI, K
    LI, SFY
    [J]. ANALYST, 1995, 120 (02) : 361 - 366
  • [10] Lide D. R., 1993, HDB CHEM PHYS