Corneal Biomechanical Parameters and Asymmetric Visual Field Damage in Patients with Untreated Normal Tension Glaucoma

被引:18
作者
Li, Bai-Bing [1 ]
Cai, Yu [1 ]
Pan, Ying-Zi [1 ]
Li, Mei [1 ]
Qiao, Rong-Hua [2 ]
Fang, Yuan [1 ]
Tian, Tian [1 ]
机构
[1] Peking Univ, Hosp 1, Dept Ophthalmol, Key Lab Vis Loss & Restorat,Minist Educ, Beijing 100034, Peoples R China
[2] Beijing Tsinghua Changgung Hosp, Dept Ophthalmol, Beijing 102218, Peoples R China
关键词
Asymmetric Visual Field Damage; Corneal Biomechanical Parameters; Corvis-ST; Normal Tension Glaucoma; Untreated; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; OCULAR HYPERTENSION; HYSTERESIS; THICKNESS;
D O I
10.4103/0366-6999.198920
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: High intraocular pressure (IOP) and low central corneal thickness (CCT) are important validated risk factors for glaucoma, and some studies also have suggested that eyes with more deformable corneas may be in higher risk of the development and worsening of glaucoma. In the present study, we aimed to evaluate the association between corneal biomechanical parameters and asymmetric visual field (VF) damage using a Corvis-ST device in patients with untreated normal tension glaucoma (NTG). Methods: In this observational, cross-sectional study, 44 newly diagnosed NTG patients were enrolled. Of these, 31 had asymmetric VF damage, which was defined as a 5-point difference between the eyes according to the Advanced Glaucoma Intervention Study scoring system. Corneal biomechanical parameters were obtained using a Corvis-ST device, such as time from start until the first and second applanation is reached (time A1 and time A2, respectively), cord length of the first and second applanation (length A1 and length A2, respectively), corneal speed during the first and second applanation (velocity A1 and velocity A2, respectively), time from start until highest concavity is reached (time HC), maximum amplitude at the apex of highest concavity (def ampl HC), distance between the two peaks at highest concavity (peak dist HC), and central concave curvature at its highest concavity (radius HC). Results: Time A1 (7.19 +/- 0.28 vs. 7.37 +/- 0.41 ms, P = 0.010), length A1 (1.73 [1.70-1.76] vs. 1.78 [1.76-1.79] mm, P = 0.007), length A2 (1.58 [1.46-1.70] vs. 1.84 [1.76-1.92] mm, P < 0.001), peak dist HC (3.53 [3.08-4.00] vs. 4.33 [3.92-4.74] mm, P = 0.010), and radius HC (6.20 +/- 0.69 vs. 6.59 +/- 1.18 mm, P = 0.032) were significantly lower in the worse eyes than in the better eyes, whereas velocity A1 and def ampl HC were significantly higher (0.156 [0.149-0.163] vs. 0.145 [0.138-0.152] m/s, P = 0.002 and 1.19 +/- 0.13 vs. 1.15 +/- 0.13 mm, P = 0.005, respectively). There was no significant difference in time A2, velocity A2, and time HC between the two groups. In addition, no difference was observed in IOP, CCT, and axial length. In the univariate and multivariate analyses, some of the Corvis-ST parameters, including time A1 and def ampl HC, were correlated with known risk factors for glaucoma, and there was also a significant positive correlation between def ampl HC and age. Conclusions: There were differences in dynamic corneal response parameters but not IOP or CCT between the paired eyes of NTG patients with asymmetric VF damage. We suggest that the shape of the cornea is more easily altered in the worse eyes of asymmetric NTG patients.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 22 条
[1]   Corneal Hysteresis and Visual Field Asymmetry in Open Angle Glaucoma [J].
Anand, Aashish ;
De Moraes, Carlos Gustavo V. ;
Teng, Christopher C. ;
Tello, Celso ;
Liebmann, Jeffrey M. ;
Ritch, Robert .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) :6514-6518
[2]   Lower corneal hysteresis in glaucoma patients with acquired pit of the optic nerve (APON) [J].
Bochmann, Frank ;
Ang, Ghee S. ;
Azuara-Blanco, Augusto .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (05) :735-738
[3]  
CARTWRIGHT MJ, 1988, ARCH OPHTHALMOL-CHIC, V106, P898
[4]   Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[5]  
Daxer A, 1998, INVEST OPHTH VIS SCI, V39, P644
[6]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714
[7]   Visual field and intraocular pressure asymmetry in the low-pressure glaucoma treatment study [J].
Greenfield, David S. ;
Liebmann, Jeffrey M. ;
Ritch, Robert ;
Krupin, Theodore .
OPHTHALMOLOGY, 2007, 114 (03) :460-465
[8]   Assessment of Corneal Biomechanical Properties in Normal Tension Glaucoma and Comparison With Open-angle Glaucoma, Ocular Hypertension, and Normal Eyes [J].
Grise-Dulac, Alice ;
Saad, Alain ;
Abitbol, Olivia ;
Febbraro, Jean-Luc ;
Azan, Elodie ;
Moulin-Tyrode, Christine ;
Gatinel, Damien .
JOURNAL OF GLAUCOMA, 2012, 21 (07) :486-489
[9]   Novel Parameter of Corneal Biomechanics That Differentiate Normals From Glaucoma [J].
Lee, Rachel ;
Chang, Robert T. ;
Wong, Ian Y. H. ;
Lai, Jimmy S. M. ;
Lee, Jacky W. Y. ;
Singh, Kuldev .
JOURNAL OF GLAUCOMA, 2016, 25 (06) :E603-E609
[10]   Predictors of long-term progression in the early manifest glaucoma trial [J].
Leske, M. Cristina ;
Heijl, Anders ;
Hyman, Leslie ;
Bengtsson, Boel ;
Dong, LiMing ;
Yang, Zhongming .
OPHTHALMOLOGY, 2007, 114 (11) :1965-1972