Should We Cross the Cross-links?

被引:13
作者
Kulkarni, Arvind G. [1 ]
Dhruv, Abhilash N. [1 ]
Bassi, Anupreet J. [1 ]
机构
[1] Bombay Hosp & Med Res Ctr, Mumbai Spine Scoliosis & Disc Replacement Ctr, Bombay 400020, Maharashtra, India
关键词
cross-links; transverse connectors; rotational stability; posterior spinal fusion; pedicle screws; scoliosis; trauma; deformity; infection; Nash-Moe method; LUMBAR INTERBODY FUSION; PEDICLE SCREW FIXATION; MEASURING VERTEBRAL ROTATION; TITANIUM MESH CAGES; POSTERIOR INSTRUMENTATION; BIOMECHANICAL EVALUATION; IDIOPATHIC SCOLIOSIS; MECHANICAL STABILITY; THORACOLUMBAR SPINE; SAME-DAY;
D O I
10.1097/BRS.0b013e31829af99f
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Retrospective study. Objective. To assess critically if cross-links are necessary adjuvants in posterior spinal constructs. Summary of Background Data. Although numerous biomechanical studies are available in the literature, there has been no clinical study that has evaluated the need for cross-links in clinical situations. Methods. The spinal constructs of patients of varied etiology who underwent surgery between July 2007 and July 2011 without the usage of cross-links were evaluated. The immediate postoperative erect radiographs were compared with the erect radiographs at the last follow-up by 2 independent observers (spine fellows not involved in the management of the patients) critically for any rotational instability using the Nash-Moe technique of assessment of vertebral rotation as well as for any "parallelogram effect." The intraobserver and interobserver reliability was analyzed. Results. There were 208 cases included in the study during the study period that satisfied the criteria. The total number of motion segments fused was 707 ranging from 1 to 15 involving various etiologies. The average follow-up was 15 months (12-36 mo). Barring one patient with a thoracolumbar fracture with rotational instability (AO [Arbeitsgemeinschaft fur Osteosynthesefragen] type C) who had undergone a short-segment fixation, none of the cases demonstrated any rotational instability in the follow-up radiographs. Interestingly, the rotational instability (parallelogram effect) in that patient got corrected spontaneously once anterior reconstruction was performed. The intraobserver reliability was 100% and the interobserver reliability was 92.83%. This variability was in assessing the grade of vertebral rotation only; none of the levels had a change in rotation irrespective of variation in grade assessment in the final postoperative radiograph. Conclusion. This study concludes that use of cross-links in clinical practice may be avoidable. The derivations from biomechanical studies do not translate into clinical advantages. Eliminating the usage of cross-links reduces the operative time as well as the overall total hospital costs (a single cross-link may cost anywhere between $ 1500 and $ 2000 and surgeons tend to use single or multiple crosslinks). Additionally, prominence of implants, corrosion, infection, implant failure, and pseudarthrosis are the other complications attributed to cross-links in the literature that can be eliminated by preventing their incorporation in spinal constructs.
引用
收藏
页码:E1128 / E1134
页数:7
相关论文
共 47 条
[1]   ESTIMATION OF VERTEBRAL ROTATION IN STRUCTURAL SCOLIOSIS BY COMPUTER TOMOGRAPHY [J].
AARO, S ;
DAHLBORN, M ;
SVENSSON, L .
ACTA RADIOLOGICA-DIAGNOSIS, 1978, 19 (06) :990-992
[2]   A MODULAR SPINAL ROD LINKAGE SYSTEM TO PROVIDE ROTATIONAL STABILITY [J].
ASHER, M ;
CARSON, W ;
HEINIG, C ;
STRIPPGEN, W ;
ARENDT, M ;
LARK, R ;
HARTLEY, M .
SPINE, 1988, 13 (03) :272-277
[3]  
ASHMAN RB, 1988, CLIN ORTHOP RELAT R, P113
[4]   En bloc resections of bone tumors of the thoracolumbar spine - A preliminary report on 29 patients [J].
Boriani, S ;
Biagini, R ;
Delure, F ;
Bertoni, F ;
Malaguti, MC ;
DiFiore, M ;
Zanoni, A .
SPINE, 1996, 21 (16) :1927-1931
[5]  
Brodke D S, 2001, Spine J, V1, P373, DOI 10.1016/S1529-9430(01)00116-4
[6]  
Brown John Carlisle, 1997, P489
[7]  
Commarmond J, 2001, REV CHIR ORTHOP, V87, P129
[8]  
Cook S, 1996, SCOL RES SOC 31 ANN
[9]   Spinal-fusion surgery - The case for restraint [J].
Deyo, RA ;
Nachemson, A ;
Mirza, SK .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (07) :722-726
[10]   Mechanical evaluation of cross-link designs in rigid pedicle screw systems [J].
Dick, JC ;
Zdeblick, TA ;
Bartel, BD ;
Kunz, DN .
SPINE, 1997, 22 (04) :370-375