Experiments on radiographic image quality using low energy portable X-ray equipments

被引:0
作者
Yabushita, N
Ooka, N
Nakamura, K
机构
[1] Nondestruct Inspect Co Ltd, Div Engn, Nishi Ku, Osaka 5500014, Japan
[2] Japan Atom Energy Res Inst, Oarai Res Estab, Oarai, Ibaraki, Japan
来源
ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3 | 2004年 / 270-273卷
关键词
radiograpy; X-ray equipment; small bore tube; image quality; computed radiography;
D O I
10.4028/www.scientific.net/KEM.270-273.1366
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We have developed new type X-ray equipments with tube voltage 75 kV (NDIC-X75) and 120 kV (NDIC-X120), both of them are light weight and ultra small in size. NDIC-X75 was applied to radiograpy of welds in small bore steel tube, and the image quality was compared to that taken by radio isotopes. The image quality using NDIC-X75 were superior to Ytterbium 169 (Yb-169). Next, NDIC-X75 and NDIC-X120 were applied to the welds in steel plate using the X-ray film and the computed radiography (CR), they showed good adaptability to CR.
引用
收藏
页码:1366 / 1370
页数:5
相关论文
共 2 条
[1]  
NISHINO S, 1993, JAP SOC NDI RES SPRI, P85
[2]   COMPUTED RADIOGRAPHY UTILIZING SCANNING LASER STIMULATED LUMINESCENCE [J].
SONODA, M ;
TAKANO, M ;
MIYAHARA, J ;
KATO, H .
RADIOLOGY, 1983, 148 (03) :833-838