The influence of the dose assessment method on the LET dependence of the relative luminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P

被引:19
作者
Parisi, Alessio [1 ,2 ]
Van Hoey, Olivier [1 ]
Megret, Patrice [2 ]
Vanhavere, Filip [1 ]
机构
[1] CEN, Belgian Nucl Res Ctr SCK, Boeretang 200, Mol, Belgium
[2] Univ Mons, Fac Engn, Blvd Dolez 31, Mons, Belgium
关键词
LiF:Mg; Ti; Cu; P; TLD; Efficiency; LET; TEMPERATURE RATIO HTR; IONIZATION DENSITY; GLOW-CURVE; THERMOLUMINESCENT EFFICIENCY; COSMIC-RADIATION; LIF DETECTORS; ENERGY IONS; LIF-MG; TI; TL;
D O I
10.1016/j.radmeas.2017.02.001
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Thermoluminescent detectors (TLDs) are solid state detectors commonly used for dose monitoring and dose mapping in many earth and space applications. Among all the crystals available, the ones based on lithium fluoride (LiF) are the most widely spread and studied around the world. In the last years the use of these TLDs in complex heavy charged particles (HCPs) fields, as in spacecraft or in radiotherapy beams, has grown rapidly leading to the necessity of an accurate characterization of the detectors' response in these radiation environments. In this work, (LiF)-Li-6:Mg,Ti, (LiF)-Li-7:Mg,Ti, (LiF)-Li-6:Mg,Cu,P and (LiF)-Li-7:Mg,Cu,P detectors were exposed to different radiation qualities in order to investigate the dependence of their relative luminescence efficiency on the linear energy transfer (LET) of the incident particles. The measured efficiencies were in good agreement with literature. In relation to this issue, different dose assessment methods, i.e. peak height, signal integration over different regions of interest (ROIs) and glow curve deconvolution, were compared and their influence on the measured relative luminescence efficiency values was assessed. For both LiF:Mg,Ti and LiF:Mg,Cu,P detectors, no relevant differences were found in the relative luminescence efficiency evaluated by means of main peak height, main peak ROI and main peak deconvolution. On the other hand, if the integration of the signal is extended to the high temperature zone (248-310 degrees C) of LiF:Mg,Ti or the low temperature zone (125-185 degrees C) of LiF:Mg,Cu,P, significant deviations were found. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 30 条
  • [1] TLD-100 thermoluminescent efficiencies for low-energy ions:: correlation of efficiency with ion incident energy
    Avila, O.
    Rodríguez-Villafuerte, M.
    Avilés, P.
    Gamboa-deBuen, I.
    Buenfil, A. E.
    Ruiz-Trejo, C.
    Concha, K.
    Brandan, M. E.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (10) : 2030 - 2037
  • [2] TL-efficiency - Overview and experimental results over the years
    Berger, T.
    Hajek, M.
    [J]. RADIATION MEASUREMENTS, 2008, 43 (2-6) : 146 - 156
  • [3] On the linearity of the high-temperature emission from 7LiF:Mg,Ti (TLD-700)
    Berger, T.
    Hajek, M.
    [J]. RADIATION MEASUREMENTS, 2008, 43 (9-10) : 1467 - 1473
  • [4] The efficiency of various thermoluminescence dosemeter types to heavy ions
    Berger, Thomas
    Hajek, Michael
    Summerer, Leopold
    Fugger, Manfred
    Vana, Norbert
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 365 - 368
  • [5] DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS)
    Berger, Thomas
    Przybyla, Bartos
    Matthiae, Daniel
    Reitz, Guenther
    Burmeister, Soenke
    Labrenz, Johannes
    Bilski, Pawel
    Horwacik, Tomasz
    Twardak, Anna
    Hajek, Michael
    Fugger, Manfred
    Hofstaetter, Christina
    Sihver, Lembit
    Palfalvi, Jozsef K.
    Szabo, Julianna
    Stradi, Andrea
    Ambrozova, Iva
    Kubancak, Jan
    Brabcova, Katerina Pachnerova
    Vanhavere, Filip
    Cauwels, Vanessa
    Van Hoey, Olivier
    Schoonjans, Werner
    Parisi, Alessio
    Gaza, Ramona
    Semones, Edward
    Yukihara, Eduardo G.
    Benton, Eric R.
    Doull, Brandon A.
    Uchihori, Yukio
    Kodaira, Satoshi
    Kitamura, Hisashi
    Boehme, Matthias
    [J]. JOURNAL OF SPACE WEATHER AND SPACE CLIMATE, 2016, 6
  • [6] Cosmic radiation exposure of biological test systems during the EXPOSE-R mission
    Berger, Thomas
    Hajek, Michael
    Bilski, Pawel
    Reitz, Gunther
    [J]. INTERNATIONAL JOURNAL OF ASTROBIOLOGY, 2015, 14 (01) : 27 - 32
  • [7] Response of various LiF thermolumine scent detectors to high energy ions - Results of the ICCHIBAN experiment
    Bilski, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 251 (01) : 121 - 126
  • [8] Dependence of the thermoluminescent high-temperature ratio (HTR) of LiF:Mg,Ti detectors on proton energy and dose
    Bilski, P.
    Sadel, M.
    Swakon, J.
    Weber, A.
    [J]. RADIATION MEASUREMENTS, 2014, 71 : 39 - 42
  • [9] Comparison of the response of various TLDs to cosmic radiation and ion beams: Current results of the HAMLET project
    Bilski, P.
    Berger, T.
    Hajek, M.
    Reitz, G.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (12) : 1680 - 1685
  • [10] Relative efficiency of TL detectors to energetic ion beams
    Bilski, P.
    Puchalska, M.
    [J]. RADIATION MEASUREMENTS, 2010, 45 (10) : 1495 - 1498