NOx treatment using low-energy secondary emission electron gun

被引:6
作者
Chalise, PR [1 ]
Wang, Y [1 ]
Mustafa, KA [1 ]
Watanabe, M [1 ]
Hayashi, Y [1 ]
Okino, A [1 ]
Hotta, E [1 ]
机构
[1] Tokyo Inst Technol, Dept Energy Sci, Yokohama, Kanagawa 2268502, Japan
关键词
low energy; NOx; treatment; secondary emission electron gun (SEEG);
D O I
10.1109/TPS.2004.831594
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
A compact and highly efficient broad electron-beam source that is capable of reducing a wide range of gaseous pollutants that are very much demanding for environmental applications. We are developing an ion-induced secondary-emission electron gun (SEEG) using wire ion-plasma source for environmental applications such as NOx treatment. The SEEG offers uniform and large cross section electron beams suitable for the efficient reduction of gaseous pollutants. We present the first report about the application of SEEG on NOx treatment. The performance of SEEG on NOx treatment is quantitatively related to removal ratio and removal efficiency of 250 ppm of NO in N-2. The electron-beam irradiation was carried out in a gas treatment chamber (13 L), where the sample flue gas was flown in ambient pressure and temperature at a controlled volumetric flow rate of 2 to 14 standard liters per minute. The NO removal characteristics have been studied under various conditions such as increased gun voltage, gas now rate, and varied pulsed-electron-beam parameters (current density and pulse length). A reasonable NO removal ratio of 20% was achieved in 60 s (repetition rate = 10 pps, current density = 28 mA/cm(2), and pulse length = 10 mus) at the accelerating gun voltage of 100 kV. The NO removal efficiency expressed in terms of specific energy cost for NO removal is 63.15 eV/molecule. It was observed that temporal and spatial characteristics of pulsed electron beam impose a substantial effect on the NO removal and the processing efficiency. We are trying to increase the processing efficiency by reducing treatment-chamber dimen
引用
收藏
页码:1392 / 1399
页数:8
相关论文
共 26 条
[1]   Characteristics of an ion induced secondary emission electron gun [J].
Chalise, PR ;
Watanabe, M ;
Okino, A ;
Ko, K ;
Hotta, E .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 2003, 12 (02) :235-243
[2]   Side-extraction-type secondary emission electron gun using wire ion plasma source [J].
Chalise, PR ;
Ishikawa, M ;
Watanabe, M ;
Okino, A ;
Ko, KC ;
Hotta, E .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (2B) :1118-1121
[3]  
CHALISE PR, 2003, UNPUB IEEE T PLASMA
[4]   Influence of the parameters of a pulsed electron beam on the removal of nitrogen oxides from flue gases [J].
Denisov, GV ;
Kuznetsov, DL ;
Novoselov, YN ;
Tkachenko, RM .
TECHNICAL PHYSICS LETTERS, 1998, 24 (08) :601-602
[5]   Repetitively pulsed plasma remediation of NOx in soot laden exhaust using dielectric barrier discharges [J].
Dorai, R ;
Kushner, MJ .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (22) :2954-2968
[6]   Multiparametric investigation on NOx removal from simulated diesel exhaust with hydrocarbons by pulsed corona discharge [J].
Filimonova, EA ;
Kim, YH ;
Hong, SH ;
Song, YH .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (21) :2795-2807
[7]   INTRODUCTION AND HISTORICAL REVIEW OF ELECTRON-BEAM PROCESSING FOR ENVIRONMENTAL-POLLUTION CONTROL [J].
FRANK, NW .
RADIATION PHYSICS AND CHEMISTRY, 1995, 45 (06) :989-1002
[8]  
GENTRY JW, 1988, RADIAT PHYS CHEM, V31, P95
[9]  
HELFRITCH DJ, 1993, SO2 NO2 REMOVAL FLUE, V34, P33
[10]   Flue gas treatment by intense pulsed relativistic electron beam [J].
Ikegaki, T ;
Seino, S ;
Oda, Y ;
Matsuda, T ;
Imada, G ;
Jiang, WH ;
Yatsui, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (2B) :1104-1107