Thick Continuous Crystal Design for PET

被引:0
|
作者
Kaul, M. [1 ]
Surti, S. [2 ]
Wiener, R. [1 ]
Karp, J. S. [1 ,2 ]
机构
[1] Univ Penn, Dept Phys, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9 | 2009年
关键词
PERFORMANCE;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our goal is to develop a thick continuous detector with high spatial resolution (1-2-mm). We will use simulations with experimental measurements to examine performance of two crystal blocks: a 50x50x25mm(3) and a 25x25x25mm(3) block of LYSO. Based upon the light distribution pattern in the 50x50x25mm(3) crystal, calculations show that a minimum spatial resolution of 2mm can be achieved in the central region of the crystal with some degradation near the edges. Monte Carlo simulations modeling Compton scatter and scintillation photon travel paths indicate that with Anger positioning, a spatial resolution of 2mm is achieved in the central region of the crystal but there is a significant degradation near the crystal edge due to light reflections. We show that we can improve the spatial resolution obtained with Anger positioning at the center and the edges of the crystal by simulating 5mm deep slots cut into the entrance surface of the crystal. Using a maximum-likelihood (ML) positioning algorithm, there is some improvement in the spatial resolution in the central region, but a more noticeable improvement at the unslotted crystal edges. We perform simulations to determine the best spatial resolution that can be achieved in the two continuous LYSO crystal blocks. We measure the energy and timing resolution of both crystals as a first step towards measuring the spatial resolution.
引用
收藏
页码:3848 / +
页数:2
相关论文
共 50 条
  • [1] Improved Statistics Based Positioning Scheme for Continuous Thick Crystal PET Detectors
    Wang Yonggang
    Cheng Xinyi
    Li Deng
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (03) : 1527 - 1532
  • [2] Improved Statistics Based Positioning Scheme for Continuous Thick Crystal PET Detectors
    Wang Yonggang
    Cheng Xinyi
    Li Deng
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2297 - 2303
  • [3] A thick crystal gamma camera design for PET and SPECT using retroreflectors.
    Strobel, J
    Clinthorne, NH
    Rogers, WL
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 111 - 111
  • [4] Towards a continuous crystal APD-based PET detector design
    Bruyndonckx, Peter
    Lemaitre, Cedric
    Schaart, Dennis
    Maas, Marnix
    van der Laan, D. J.
    Krieguer, Magalie
    Devroede, Olivier
    Tavernier, Stefaan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 182 - 186
  • [5] DESIGN AND SIMULATION OF A GAMMA-RAY CAMERA FOR PET WITH A CONTINUOUS SCINTILLATION CRYSTAL
    Boghrati, Behzad
    Zarandi, Ali Moussavi
    Ghergherehchi, Mitra
    Chai, Jong Seo
    NUCLEAR TECHNOLOGY, 2012, 178 (03) : 324 - 334
  • [6] A Continuous Crystal Detector for TOF PET
    Szczesniak, T.
    Moszynski, M.
    Swiderski, L.
    Nassalski, A.
    Syntfeld-Kazuch, A.
    Ojala, P.
    Bohm, C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3205 - +
  • [7] A Time Resolution Study of a Continuous Crystal Detector for TOF PET
    Szczesniak, T.
    Moszynski, M.
    Swiderski, L.
    Nassalski, A.
    Syntfeld-Kazuch, A.
    Ojala, P.
    Bohm, C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 40 - 47
  • [8] Energy and spatial resolution for a continuous scintillation crystal - interface - continuous scintillation crystal system in Positron Emission Tomography(PET)
    Carles, M.
    Ros-Garcia, A.
    Lerche, Ch. W.
    Sanchez, F.
    Sebastia, A.
    Benlloch, J. M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3181 - +
  • [9] The effect of photon incident angle on spatial resolution with thick crystal hybrid PET.
    Glick, SJ
    Stodilka, RZ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 56P - 56P
  • [10] Parametric positioning of a continuous crystal PET detector with depth of interaction decoding
    Ling, T.
    Burnett, T. H.
    Lewellen, T. K.
    Miyaoka, R. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (07): : 1843 - 1863