Accurate and reliable U-value assessment of argon-filled double glazed windows: A numerical and experimental investigation

被引:54
作者
Cuce, Erdem [1 ]
机构
[1] Univ Bayburt, Dept Mech Engn, Fac Engn, Dede Korkut Campus, TR-69000 Bayburt, Turkey
关键词
U-value assessment; Double glazed windows; Thermal resistance; Energy losses in buildings; GLAZING TECHNOLOGIES; CARBON BUILDINGS; PRODUCT;
D O I
10.1016/j.enbuild.2018.04.036
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
U-value assessment is a significant process to be able to evaluate the thermal insulation performance of building materials notably windows. About 60% of energy losses from building envelope is attributed to windows, hence accurate and reliable thermal resistance evaluation of glazed areas is of vital importance for a sensitive energy demand analysis of buildings. U-value assessment of windows is usually conducted through theoretical and numerical methods in literature. However, dwellers frequently complain about the insufficient thermal insulation performance of commercial glazing products when compared to the reported U-values in datasheets. This inconvenience arises from the lack of comprehensive experimental tests which simulate the actual operating conditions. Therefore, in this research, argon filled double glazed windows, which is one the most common fenestration products in market, is numerically and experimentally analysed in terms of U-value performance. Although computational fluid dynamics (CFD) analyses reveal that the U-value of the reference sample (4 mm pane + 20 mm argon + 4 mm pane) is 0.89 W/m(2)K, which is in good accordance with the theoretical data (0.80 W/m(2)K), it is observed from the environmental chamber tests that the U-value in simulated operating conditions is 1.25, 1.18 and 1.32 W/m(2)K for top, centre and lower positions of the window sample. The tests are repeated for accuracy verification, and the U-value is found to be 1.23, 1.18 and 1.31 W/m(2)K for the said points. In this respect, it is concluded that thermal bridges and edge effects play a key role in actual U-value performance of glazing products. Therefore, experimental performance figures are recommended to be utilised in energy demand analyses of buildings. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:100 / 106
页数:7
相关论文
共 23 条
[1]  
[Anonymous], 2012, OREGON RESIDENTIAL E
[2]   Window and advanced glazing systems life cycle assessment [J].
Citherlet, S ;
Di Guglielmo, F ;
Gay, JB .
ENERGY AND BUILDINGS, 2000, 32 (03) :225-234
[3]  
Communities and Local Government, 2006, COD SUST HOM STEP CH
[4]  
Cuce E, 2015, THERMAL SUPERINSULAT
[5]  
Cuce E, 2014, THESIS
[6]  
Cuce E., 2009, 4 INT EX EN ENV S 19
[7]  
Cuce E., 2016, 15 INT C SUST EN TEC
[8]  
Cuce E, 2010, 5 INT EG EN S EXH 27
[9]   A smart building material for low/zero carbon applications: heat insulation solar glass-characteristic results from laboratory and in situ tests [J].
Cuce, Erdem ;
Riffat, Saffa B. .
INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2017, 12 (02) :126-135
[10]   Role of airtightness in energy loss from windows: Experimental results from in-situ tests [J].
Cuce, Erdem .
ENERGY AND BUILDINGS, 2017, 139 :449-455