Analytical quality solid-state composite reference electrode manufactured by injection moulding

被引:23
作者
Granholm, Kim [1 ]
Mousavi, Zekra [1 ]
Sokalski, Tomasz [1 ]
Lewenstam, Andrzej [1 ,2 ]
机构
[1] Abo Akad Univ, Proc Chem Ctr, Analyt Chem Lab, Turku 20500, Finland
[2] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
关键词
Potentiometry; Reference electrode; Solid contact; Maintenance-free sensor; MINIATURIZED REFERENCE ELECTRODES;
D O I
10.1007/s10008-013-2294-x
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
An injection moulding method was used for fabricating solid-state reference electrodes (Ag/AgCl type) based on a polymer/inorganic salt composite. In this method, a silver/silver chloride wire was placed inside a mould into which the mixture of polymer and inorganic salt was injected. The obtained solid-state composite reference electrodes were extensively tested to study the influence of different parameters such as solution composition, the concentrations and mobility of ions and pH on the potential stability of the electrodes. These experiments revealed that the composite reference electrodes are insensitive to the matrix effect, have excellent potential readings stability and considerably reduced leakage of inorganic salt. The composite reference electrodes were compared favourably to high-quality commercial reference electrodes. It was concluded that the composite reference electrodes obtained by injection moulding are of analytical quality allowing for continuous, prolonged and intensive usage.
引用
收藏
页码:607 / 612
页数:6
相关论文
共 18 条
[1]   Development of miniature all-solid-state potentiometric sensing system [J].
Anastasova-Ivanova, Salzitsa ;
Mattinen, Ulriika ;
Radu, Aleksandar ;
Bobacka, Johan ;
Lewenstam, Andrzej ;
Migdalski, Jan ;
Danielewskic, Marek ;
Diamond, Dermot .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :199-205
[2]  
Bakker E, 1999, ELECTROANAL, V11, P788, DOI 10.1002/(SICI)1521-4109(199907)11:10/11<788::AID-ELAN788>3.0.CO
[3]  
2-4
[4]   Junction-less reference electrode for potentiometric measurements obtained by buffering pH in a conducting polymer matrix [J].
Blaz, T ;
Migdalski, J ;
Lewenstam, A .
ANALYST, 2005, 130 (05) :637-643
[5]   Ionic Liquid-Based, Liquid-Junction-Free Reference Electrode [J].
Cicmil, Dimitrije ;
Anastasova, Salzitsa ;
Kavanagh, Andrew ;
Diamond, Dermot ;
Mattinen, Ulriika ;
Bobacka, Johan ;
Lewenstam, Andrzej ;
Radu, Aleksandar .
ELECTROANALYSIS, 2011, 23 (08) :1881-1890
[6]   Miniaturized reference electrodes. II. Use in corrosive, biological, and organic media [J].
Ciobanu, M ;
Wilburn, JP ;
Lowy, DA .
ELECTROANALYSIS, 2004, 16 (16) :1351-1358
[7]  
Ciobanu M, 2002, ELECTROANAL, V14, P989, DOI 10.1002/1521-4109(200208)14:14<989::AID-ELAN989>3.0.CO
[8]  
2-6
[9]   EVALUATION OF A NEW SOLID-STATE REFERENCE ELECTRODE JUNCTION MATERIAL FOR ION-SELECTIVE ELECTRODES [J].
DIAMOND, D ;
MCENROE, E ;
MCCARRICK, M ;
LEWENSTAM, A .
ELECTROANALYSIS, 1994, 6 (11-12) :962-971
[10]   Determination of Calcium with Ion-Selective Electrode in Black Liquor from a Kraft Pulping Process [J].
Granholm, Kim ;
Ek, Paul ;
Sokalski, Tomasz ;
Harju, Leo ;
Bobacka, Johan ;
Ivaska, Ari .
ELECTROANALYSIS, 2009, 21 (17-18) :2014-2021