Evaluation of adnexal masses using three-dimensional ultrasonographic technology: Preliminary report

被引:21
作者
Chan, L
Lin, WM
Uerpairojkit, B
Hartman, D
Reece, EA
Helm, W
机构
关键词
three-dimensional ultrasonography; adnexa; mass; transvaginal ultrasonography; adnexal; ovary;
D O I
10.7863/ultra.16.5.349
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of the current study was to demonstrate the ability of three-dimensional ultrasonographic technology to enhance the morphologic scoring system and further improve the ability to differentiate benign from malignant ovarian masses. We performed conventional two-dimensional and three-dimensional transabdominal and transvaginal ultrasonography on eight women with adnexal masses. All patients underwent exploratory laparotomy or diagnostic laparoscopy. The three-dimensional ultrasonographic findings were compared with the two-dimensional ultrasonograms, the intraoperative observations, and gross and histopathologic findings. The morphologic scoring system as described by Sassone and coworkers was adopted, with scores of less than 9 suggestive of benign lesions, and this system was applied in both the two-dimensional and three-dimensional ultrasonographic examinations. The morphologic scores were subsequently compared. The images were dissected in the XYZ planes, and the areas suggestive of malignancy, as suggested by two-dimensional ultrasonography, were determined to be either negative or positive and confirmatory. In each of the eight adnexal masses, three-dimensional ultrasonography confirmed the preoperative diagnoses. The morphologic scores did not differ between two-dimensional and three-dimensional ultrasonograms for the benign cysts. In one case of benign solid fibroma, both the two-dimensional and three-dimensional gray scale morphologic scores were falsely positive at greater than 9. In one case of malignant serous papillary cystadenocarcinoma the two-dimensional morphologic score was a 9, whereas the three-dimensional score was 13. This difference in scores can be attributed to the additional views available with three-dimensional volume scanning, which allowed better characterization of the pathologic conditions. In addition, three-dimensional sonographic technology had the added advantage of high-speed image acquisition and recording to decrease the time of scaling to improve patient comfort. Furthermore, three-dimensional ultrasonography allowed the real-time analysis of the acquired image data to be conducted at a later time when the patient is off the examination table. Our preliminary results suggest that three-dimensional transvaginal ultrasonographic technology can enhance and facilitate the morphologic evaluation of both benign and malignant adnexal masses.
引用
收藏
页码:349 / 354
页数:6
相关论文
共 8 条
[1]  
ANDOLF E, 1988, J ULTRAS MED, V7, P617
[2]   3-DIMENSIONAL ULTRASOUND EVALUATION OF OVARIAN MASSES [J].
BONILLAMUSOLES, F ;
RAGA, F ;
OSBORNE, NG .
GYNECOLOGIC ONCOLOGY, 1995, 59 (01) :129-135
[3]   TRANS-ABDOMINAL ULTRASOUND SCREENING FOR EARLY OVARIAN-CANCER [J].
CAMPBELL, S ;
BHAN, V ;
ROYSTON, P ;
WHITEHEAD, MI ;
COLLINS, WP .
BMJ-BRITISH MEDICAL JOURNAL, 1989, 299 (6712) :1363-1367
[4]  
DI-XIA C, 1988, Obstetrics and Gynecology, V72, P23
[5]  
LERNER JP, 1994, AM J OBSTET GYNECOL, V170, P81
[6]  
SASSONE AM, 1991, OBSTET GYNECOL, V78, P70
[7]   3-DIMENSIONAL ULTRASOUND IN OBSTETRICS AND GYNECOLOGY - TECHNIQUE, POSSIBILITIES AND LIMITATIONS [J].
STEINER, H ;
STAUDACH, A ;
SPITZER, D ;
SCHAFFER, H .
HUMAN REPRODUCTION, 1994, 9 (09) :1773-1778
[8]   TRANSVAGINAL ULTRASONOGRAPHIC CHARACTERIZATION OF OVARIAN MASSES BY MEANS OF COLOR FLOW-DIRECTED DOPPLER MEASUREMENTS AND A MORPHOLOGIC SCORING SYSTEM [J].
TIMORTRITSCH, IE ;
LERNER, JP ;
MONTEAGUDO, A ;
SANTOS, R .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 168 (03) :909-913