摘要
Introduction. This study investigated the radiographic and functional outcomes of two different methods for treating fractures of the distal part of the radius. Patients and methods. In a prospective controlled study patients with forearm fractures were randomized by age, handedness, and fracture type. Results. The study included 120 patients, with a mean age of 66 years. Forty-nine percent of the fractures were extraarticular, and 51% were intraarticular. In the group treated with volar locking compression plates, six patients needed operative decompression of the median nerve and one needed reconstruction of the extensor pollicis longus (EPL) tendon. The group with dorsal plating had three complications requiring operative treatment: one deep infection, one dislocation of the plate, and one reconstruction of the EPL tendon. The radiological results for the Stewart 1 score showed 68% excellent results in volar locking compression plating compared with 57% in dorsal plating. Regarding functional outcome, 48% with volar plating showed excellent results compared with 22% with dorsal plating, as measured by the Stewart 2 score. Conclusion. Despite significant advantages of the volar locked compression plating, subjective satisfaction did not differ between the two groups.
引用
收藏
页码:712 / +
页数:6
相关论文
共 27 条
[1]   Limits of palmar locking-plate osteosynthesis of unstable distal radius fractures [J].
Arora, R. ;
Lutz, M. ;
Zimmermann, R. ;
Krappinger, D. ;
Gabl, M. ;
Pechlaner, S. .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2007, 39 (01) :34-41
[2]   Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures [J].
Arora, R ;
Lutz, M ;
Fritz, D ;
Zimmermann, R ;
Oberladstätter, J ;
Gabl, M .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (06) :399-404
[3]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[4]   Treatment of unstable distal radial fractures with the volar locking plating system [J].
Chung, Kevin C. ;
Watt, Andrew J. ;
Kotsis, Sandra V. ;
Margaliot, Zvi ;
Haase, Steven C. ;
Kim, Myra .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) :2687-2694
[5]  
Dumont C, 2003, CHIRURG, V74, P827, DOI 10.1007/s00104-003-0667-x
[6]   The operative therapy of distal unstable radius fractures with dorsal and volar plates. A retrospective study with respect to the DASH-score system [J].
Felderhoff, J ;
Wiemer, P ;
Dronsella, J ;
Weber, U .
ORTHOPADE, 1999, 28 (10) :853-+
[7]   Distal radius fracture [J].
Gabl, Markus .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2007, 39 (01) :1-1
[8]   EVALUATION OF HEALED COLLES FRACTURES [J].
GARTLAND, JJ ;
WERLEY, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1951, 33-A (04) :895-907
[9]  
Kamano M, 2002, CLIN ORTHOP RELAT R, P403
[10]  
Krimmer H, 2004, UNFALLCHIRURG, V107, P460, DOI 10.1007/s00113-004-0794-y