Nondestructive assessment of corrosion of reinforcing bars through surface concrete cracks

被引:54
作者
Bossio, Antonio [1 ,2 ]
Lignola, Gian Piero [1 ]
Fabbrocino, Francesco [3 ]
Monetta, Tullio [2 ]
Prota, Andrea [1 ]
Bellucci, Francesco [2 ]
Manfredi, Gaetano [1 ]
机构
[1] Univ Naples Federico II, Dept Struct Engn & Architecture, Naples, Italy
[2] Univ Naples Federico II, Dept Chem Engn Mat & Prod, Naples, Italy
[3] Pegaso Telemat Univ, Dept Engn, Naples, Italy
关键词
assessment; corrosion; crack width; experimental tests; nondestructive tests; reinforcement; INDUCED COVER CRACKING; CORRODED BARS; PREDICTION; LIFE;
D O I
10.1002/suco.201600034
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Degradation of reinforced concrete (RC) structures is a serious safety problem affecting all industrialized countries, and the economical aspect of this problem cannot be neglected. One of the main reasons for the degradation of RC is the corrosion of steel reinforcing bars as a result of concrete cover cracking and reduction in bar cross section. As a consequence, the structural capacity of RC elements decreases progressively as degradation develops. Nondestructive testing and/or analytical formulation represent high-quality rapid methods for evaluating the corrosion penetration of bars and provide useful parameters for designing retrofits. This paper presents an additional tool that can be used to evaluate and assess the vulnerability of existing structures in terms of the determination of bar cross section lost. Using simple charts and formulas, this can be accomplished by calculating reinforcing bar cross section loss due to corrosion by measuring external crack widths in the concrete cover. Predictions were obtained by using two analytical models developed. These predictions have been satisfactorily compared with both the literature and new experimental results, as well as with previous empirical models available in the scientific literature. The experimental results were obtained by corroding real-scale concrete specimens reinforced with smooth and ribbed bars (according to old and modern building codes) using 3.5 wt% sodium chloride solution and an applied current.
引用
收藏
页码:104 / 117
页数:14
相关论文
共 40 条
[2]   Factors controlling cracking of concrete affected by reinforcement corrosion [J].
Alonso, C ;
Andrade, C ;
Rodriguez, J ;
Diez, JM .
MATERIALS AND STRUCTURES, 1998, 31 (211) :435-441
[3]   COVER CRACKING AS A FUNCTION OF BAR CORROSION .1. EXPERIMENTAL TEST [J].
ANDRADE, C ;
ALONSO, C ;
MOLINA, FJ .
MATERIALS AND STRUCTURES, 1993, 26 (162) :453-464
[4]   Estimating corrosion attack in reinforced concrete by means of crack opening [J].
Andrade, Carmen ;
Cesetti, Alessandro ;
Mancini, Giuseppe ;
Tondolo, Francesco .
STRUCTURAL CONCRETE, 2016, 17 (04) :533-540
[5]  
[Anonymous], 2013, P 1 INT C CONCR SUST
[6]  
[Anonymous], FHWARD01156 US DEP T
[7]  
[Anonymous], 1995, DURABILITA OPERE CAL
[8]  
[Anonymous], P 4 INT S BOND CONCR
[9]  
[Anonymous], SP03902009 NACE
[10]  
[Anonymous], P 2 INT C CONCR REP