Dynamics of Ultrasonic Transducer System for Thermosonic Flip Chip Bonding

被引:21
作者
Long, Zhili [1 ]
Wu, Yunxin [1 ]
Han, Lei [1 ]
Zhong, Jue [1 ]
机构
[1] Cent S Univ, Dept Mechatron, Changsha 410083, Peoples R China
来源
IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES | 2009年 / 32卷 / 02期
基金
美国国家科学基金会;
关键词
Dynamical properties; finite element method (FEM) analysis; thermosonic flip chip bonding; ultrasonic transducer;
D O I
10.1109/TCAPT.2009.2017380
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Thermosonic flip chip bonding is used in certain fine pitch IC packaging for its unique features. By using this bonding process in this paper, 1 mm x 1 mm chip with 8 gold bumps has been bonded onto a silver-coated substrate. Dynamical properties of transducer system, which is the key component for providing the ultrasonic energy, have been investigated using finite element model (FEM) and measurement using impedance analyzer and laser doppler vibrometer (LDV). The simulation results show that the ultrasonic transducer vibrates by coupling with all excited modes, therefore resulting in complicated motions during bonding. The third axial mode, which includes 1.5 wavelengths and 3 nodes, is the dominant working vibration. However, this axial mode is severely disturbed by undesirable non-axial modes such as flexural modes. There are some other unwanted parasitic modes close to dominant mode. Measured velocities of the transducer horn show that the system vibrates under several modes simultaneously. The impedance measurements reveal additional frequencies overlapping the working frequency. All non-axial modes of the ultrasonic transducer disturb the bonding process and degrade the bonding quality. A subtle control is needed to obtain unique axial mode and stable vibration for high bonding quality.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 17 条
[1]  
ANSYS Inc, 2004, ANSYS REL 9 0 DOC
[2]  
Harman G.G., 1997, WIRE BONDING MICROEL
[3]   MODELING AND EXPERIMENTAL STUDIES ON THERMOSONIC FLIP-CHIP BONDING [J].
KANG, SY ;
WILLIAMS, PM ;
LEE, YC .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART B-ADVANCED PACKAGING, 1995, 18 (04) :728-733
[4]  
KANG SY, 1995, THESIS U COLORADO BO
[5]  
Long ZL, 2005, PROCEEDINGS OF THE SEVENTH IEEE CPMT CONFERENCE ON HIGH DENSITY MICROSYSTEM DESIGN, PACKAGING AND FAILURE ANALYSIS (HDP'05), P419
[6]  
Luan G., 2005, Piezoelectric Transducers and transducer Arrays
[7]   Piezocomposite ultrasonic transducer for high-frequency wire-bonding of microelectronics devices [J].
Or, Siu Wing ;
Chan, Helen Lai Wa ;
Liu, Peter Chou Kee .
SENSORS AND ACTUATORS A-PHYSICAL, 2007, 133 (01) :195-199
[8]   Dynamics of an ultrasonic transducer used for wire bonding [J].
Or, SW ;
Chan, HLW ;
Lo, VC ;
Yuen, CWM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (06) :1453-1460
[9]   New techniques for the design of advanced ultrasonic transducers for wire bonding [J].
Parrini, L .
IEEE TRANSACTIONS ON ELECTRONICS PACKAGING MANUFACTURING, 2003, 26 (01) :37-45
[10]   A simple transducer model for longitudinal flip-chip bonding [J].
Sattel, T ;
Brökelmann, M .
2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, :695-698