FBP initialization for transition artifacts reduction in statistical X-ray CT reconstruction.

被引:0
|
作者
Zbijewski, W [1 ]
Beekman, FJ [1 ]
机构
[1] UMC Utrecht, Imaging Sci Inst, Dept Nucl Med, NL-3584 CG Utrecht, Netherlands
来源
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5 | 2004年
关键词
imaging; maximum likelihood; tomography; iterative reconstruction; artifact reduction;
D O I
10.1109/NSSMIC.2003.1352507
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
When statistical reconstruction (SR) algorithms are applied to X-ray CT data, the resulting images may contain some disturbing streak artifacts emerging from high-contrast structures. Extremely high number of iterations needed to remove such disturbancies may seriously slow down the reconstruction process. In this paper we demonstrate (using the Ordered Subsets Convex algorithm) that these artifacts can be adequately suppressed if statistical reconstruction is initialized with images generated by means of analytical algorithms like Filtered Back Projection (FBP). This allows the reconstruction time to be shortened by even as much as one order of magnitude. Although the initialization of the statistical algorithm with FBP image introduces some additional noise into the first iteration of OSC reconstruction, the resolution-noise trade-off and the contrast-to-noise ratio of final images are not markedly compromised.
引用
收藏
页码:2970 / 2972
页数:3
相关论文
共 50 条
  • [41] Accelerating Ordered Subsets Image Reconstruction for X-ray CT Using Spatially Nonuniform Optimization Transfer
    Kim, Donghwan
    Pal, Debashish
    Thibault, Jean-Baptiste
    Fessler, Jeffrey A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (11) : 1965 - 1978
  • [42] Reconstruction of soft x-ray emission in MAST Upgrade
    Steward, B. A.
    Cecconello, M.
    Bowman, C.
    MAST-U Team
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (12)
  • [43] A novel simulation-driven reconstruction approach for x-ray computed tomography
    Hsieh, Jiang
    MEDICAL PHYSICS, 2022, 49 (04) : 2245 - 2258
  • [44] Prototyping X-ray tomographic reconstruction pipelines with FleXbox
    Kostenko, A.
    Palenstijn, W. J.
    Coban, S. B.
    Hendriksen, A. A.
    van Liere, R.
    Batenburg, K. J.
    SOFTWAREX, 2020, 11
  • [45] A correction procedure for the self-absorption artifacts in X-Ray Compton tomography
    Brunetti, A
    Golosio, B
    Cesareo, R
    Borlino, CC
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 132 - 139
  • [46] Archeological ceramic artifacts characterization through computed microtomography and X-ray fluorescence
    Machado, A. S.
    Oliveira, D. F.
    Gama, H. S.
    Latini, R.
    Bellido, A. V. B.
    Assis, J. T.
    Anjos, M. J.
    Lopes, R. T.
    X-RAY SPECTROMETRY, 2017, 46 (05) : 427 - 434
  • [47] Approaching quantitative Zernike phase contrast in full-field transmission hard X-ray microscopy: Origin and reduction of artifacts
    Yang, Yang
    Heine, Ruth
    Cheng, Yin
    Wang, Chun-Chieh
    Song, Yen-Fang
    Baumbach, Tilo
    APPLIED PHYSICS LETTERS, 2014, 105 (09)
  • [48] Patient size and x-ray transmission in body CT
    Ogden, K
    Huda, W
    Scalzetti, EM
    Roskopf, ML
    HEALTH PHYSICS, 2004, 86 (04): : 397 - 405
  • [49] In situ phase contrast X-ray brain CT
    Croton, Linda C. P.
    Morgan, Kaye S.
    Paganin, David M.
    Kerr, Lauren T.
    Wallace, Megan J.
    Crossley, Kelly J.
    Miller, Suzanne L.
    Yagi, Naoto
    Uesugi, Kentaro
    Hooper, Stuart B.
    Kitchen, Marcus J.
    SCIENTIFIC REPORTS, 2018, 8
  • [50] A quantitative correction for phase wrapping artifacts in hard X-ray grating interferometry
    Rodgers, Griffin
    Schulz, Georg
    Deyhle, Hans
    Marathe, Shashidhara
    Bikis, Christos
    Weitkamp, Timm
    Muller, Bert
    APPLIED PHYSICS LETTERS, 2018, 113 (09)