Influence of stress and phase on corrosion of a superelastic nickel-titanium orthodontic wire

被引:20
|
作者
Segal, Nadav [1 ]
Hell, Jess
Berzins, David W. [1 ]
机构
[1] Marquette Univ, Sch Dent, Dept Dev Sci, Milwaukee, WI 53201 USA
关键词
STAINLESS-STEEL; MECHANICAL-PROPERTIES; ALLOY; RESISTANCE; ARCHWIRES; NITI;
D O I
10.1016/j.ajodo.2007.04.042
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this investigation was to study the effect of stress and phase transformation on the corrosion properties of a superelastic nickel-titanium orthodontic wire. Methods: The phase transformation profiles of superelastic nickel-titanium (Sentalloy, GAC International, Bohemia, NY) and beta-titanium (TMA, Ormco, Orange, Calif) archwires were analyzed by using differential scanning calorimetry. The force/deflection behavior of the wires at 37 degrees C was measured in a 3-point bending test per modified American Dental Association specification no. 32. Electrochemical testing consisted of monitoring the open circuit potential (OCP) for 2 hours followed by polarization resistance and cyclic polarization tests on archwire segments engaged in a 5-bracket simulation apparatus with bend deflections of 0.75, 1.5, or 3 mm in artificial saliva at 37 degrees C. Nondeflected segments were also tested. Sentalloy was additionally examined for bending and corrosion at 5 degrees C, where it exists as martensite and is devoid of stress-induced phase transformation. OCP at 2 hours and corrosion current density (i(corr)) were analyzed by using ANOVA and Tukey tests (alpha = .05) (n = 10 per deflection). Results: Significant differences (P < 0.05) in OCP with deflection were found for the TMA and the Sentalloy wires at 5 degrees C, but not for Sentalloy at 37 degrees C. Significant differences (P <0.05) in i(corr) with deflection were also observed. All 3 wire groups had their lowest mean icorr values when not deflected. The i(corr) for superelastic Sentalloy (37 degrees C) peaked at 0.75 mm deflection before the wire's stress-induced phase transformation point and then decreased with further deflection and transformation. The i(corr) values for TMA and Sentalloy at 5 degrees C, both of which do not undergo phase transformation with deformation, continuously increased from 0 to 1.5 mm deflection before decreasing at the 3.0-mm deflection. Conclusions: Stress increased the corrosion rate in nickel-titanium and beta-titanium orthodontic wires. Alterations in stress/strain associated with phase transformation in superelastic nickel-titanium might alter the corrosion rate in ways different from wires not undergoing phase transformation. (Am J Orthod Dentofacial Orthop 2009;135:764-70)
引用
收藏
页码:764 / 770
页数:7
相关论文
共 50 条
  • [21] A study of corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and TMA orthodontic wires with potentiostatic anodic polarization.
    Kim, H
    Johnson, JW
    Ngan, P
    Durkee, M
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 278 - 278
  • [22] GEOMETRIC AND MATERIAL PARAMETERS OF A NICKEL-TITANIUM AND A BETA-TITANIUM ORTHODONTIC ARCH WIRE ALLOY
    KUSY, RP
    STUSH, AM
    DENTAL MATERIALS, 1987, 3 (04) : 207 - 217
  • [23] Corrosion of nickel-titanium instruments
    Sonntag, David
    Heithecker, Karolin
    ENDO-ENDODONTIC PRACTICE TODAY, 2008, 2 (03): : 185 - 191
  • [24] Influence of intraoral application of antiseptics and fluorides during orthodontic treatment on corrosion and mechanical characteristics of nickel-titanium alloy in orthodontic appliances
    Belasic, Tihana Zibar
    Pejova, Biljana
    Curkovic, Helena Otmacic
    Kamenar, Ervin
    Cetenovic, Bojana
    Spalj, Stjepan
    ANGLE ORTHODONTIST, 2021, 91 (04) : 528 - 537
  • [25] Damping Capacity of Superelastic Nickel-Titanium Plain Textiles
    Heller, L.
    Marvalova, B.
    Vlach, J.
    Janouchova, K.
    Syrovatkova, M.
    Hanus, J.
    VIBRATION PROBLEMS ICOVP 2011, 2011, 139 : 565 - 572
  • [26] The effect of short-term temperature changes on superelastic nickel-titanium archwires activated in orthodontic bending
    Meling, TR
    Odegaard, J
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2001, 119 (03) : 263 - 273
  • [27] DMTA study of a nickel-titanium wire
    Artiaga, R
    García, A
    García, L
    Varela, A
    Mier, JL
    Naya, S
    Graña, M
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2002, 70 (01): : 199 - 207
  • [28] DMTA study of a nickel-titanium wire
    R. Artiaga
    A. Garcia
    L. Garcia
    A. Varela
    J. L. Mier
    S. Naya
    M. Grana
    Journal of Thermal Analysis and Calorimetry, 2002, 70 : 199 - 207
  • [29] Comparison of the Mechanical Properties of Rotary Instruments Made of Conventional Nickel-Titanium Wire, M-Wire, or Nickel-Titanium Alloy in R-Phase
    Lopes, Helio P.
    Gambarra-Soares, Thaiane
    Elias, Carlos N.
    Siqueira, Jose F., Jr.
    Inojosa, Ines F. J.
    Lopes, Weber S. P.
    Vieira, Victor T. L.
    JOURNAL OF ENDODONTICS, 2013, 39 (04) : 516 - 520
  • [30] Determination of corrosion rate of orthodontic wires based on nickel-titanium alloy in artificial saliva
    Katic, V.
    Curkovic, L.
    Bosnjak, M. Ujevic
    Spalj, S.
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2014, 45 (02) : 99 - 105