High-resolution 3D whole-heart coronary MRA: a study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation

被引:27
作者
Forman, Christoph [1 ,2 ]
Piccini, Davide [3 ,4 ,5 ]
Grimm, Robert [1 ]
Hutter, Jana [1 ,2 ]
Hornegger, Joachim [1 ,2 ]
Zenge, Michael O. [6 ]
机构
[1] Univ Erlangen Nurnberg, Dept Comp Sci, Pattern Recognit Lab, D-91058 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Erlangen Grad Sch Adv Opt Technol SAOT, D-91058 Erlangen, Germany
[3] Siemens Healthcare H IM BM PI, Adv Clin Imaging Technol, Lausanne, Switzerland
[4] Univ Hosp CHUV, Dept Radiol, Lausanne, Switzerland
[5] Univ Lausanne UNIL, Ctr Biomed Imaging CIBM, Lausanne, Switzerland
[6] Siemens AG, Healthcare Sect, MR Prod Innovat & Definit, Erlangen, Germany
关键词
Coronary magnetic resonance angiography; Multiple breath-holds; Respiratory motion compensation; Compressed sensing; MAGNETIC-RESONANCE ANGIOGRAPHY; PROJECTION RECONSTRUCTION; IMAGE-RECONSTRUCTION; NAVIGATOR CORRECTION; CONSTRUCT; SENSE;
D O I
10.1007/s10334-013-0428-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To study a scan protocol for coronary magnetic resonance angiography based on multiple breath-holds featuring 1D motion compensation and to compare the resulting image quality to a navigator-gated free-breathing acquisition. Image reconstruction was performed using L1 regularized iterative SENSE. The effects of respiratory motion on the Cartesian sampling scheme were minimized by performing data acquisition in multiple breath-holds. During the scan, repetitive readouts through a k-space center were used to detect and correct the respiratory displacement of the heart by exploiting the self-navigation principle in image reconstruction. In vivo experiments were performed in nine healthy volunteers and the resulting image quality was compared to a navigator-gated reference in terms of vessel length and sharpness. Acquisition in breath-hold is an effective method to reduce the scan time by more than 30 % compared to the navigator-gated reference. Although an equivalent mean image quality with respect to the reference was achieved with the proposed method, the 1D motion compensation did not work equally well in all cases. In general, the image quality scaled with the robustness of the motion compensation. Nevertheless, the featured setup provides a positive basis for future extension with more advanced motion compensation methods.
引用
收藏
页码:435 / 443
页数:9
相关论文
共 36 条
[1]   Accelerated contrast-enhanced whole-heart coronary MRI using low-dimensional-structure self-learning and thresholding [J].
Akcakaya, Mehmet ;
Basha, Tamer A. ;
Chan, Raymond H. ;
Rayatzadeh, Hussein ;
Kissinger, Kraig V. ;
Goddu, Beth ;
Goepfert, Lois A. ;
Manning, Warren J. ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) :1434-1443
[2]  
Block K.T., 2011, P 19 ANN M ISMRM MON, V2816
[3]   Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint [J].
Block, Kai Tobias ;
Uecker, Martin ;
Frahm, Jens .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1086-1098
[4]   Whole-Heart Imaging Using Undersampled Radial Phase Encoding (RPE) and Iterative Sensitivity Encoding (SENSE) Reconstruction [J].
Boubertakh, R. ;
Prieto, C. ;
Batchelor, P. G. ;
Uribe, S. ;
Atkinson, D. ;
Eggers, H. ;
Sorensen, T. S. ;
Hansen, M. S. ;
Razavi, R. S. ;
Schaeffter, T. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (05) :1331-1337
[5]  
Cheng JY, 2013, P 21 SCI M INT SOC M, P1506
[6]   Prospective navigator correction of image position for coronary MR angiography [J].
Danias, PG ;
McConnell, MV ;
Khasgiwala, VC ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
RADIOLOGY, 1997, 203 (03) :733-736
[7]  
Doneva M, 2012, P 20 SCI M INT SOC M, P2240
[8]  
Forman C., 2012, Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Victoria, Australia, P1160
[9]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[10]   The promise of whole-heart coronary MRI [J].
Hauser T.H. ;
Manning W.J. .
Current Cardiology Reports, 2008, 10 (1) :46-50