Energy saving and environmental impact of optimizing the number of condenser fans in centrifugal chillers under partial load operation

被引:22
作者
Deymi-Dashtebayaz, Mahdi [1 ]
Farahnak, Mehdi [2 ]
Abadi, Reza Nazeri Boori [1 ]
机构
[1] Hak Sabzevari Univ, Dept Mech Engn, Sabzevar, Iran
[2] Islamic Azad Univ, Rasht Branch, Young Researchers & Elite Club, Rasht, Iran
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2019年 / 103卷
关键词
Maximum coefficient of performance; Partial load optimization; Vapor compression chiller; Optimal number of condenser fans; AIR-COOLED CHILLERS; THERMODYNAMIC ANALYSIS; COMMERCIAL BUILDINGS; PERFORMANCE; SYSTEM; TEMPERATURE; EFFICIENCY; OPTIMIZATION; VENTILATION; SIMULATION;
D O I
10.1016/j.ijrefrig.2019.03.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, an optimization model is extended to optimize the coefficient of performance of refrigeration systems at partial load operation, based on optimal number of condenser fans. The sizes of vapor compression chillers are 703, 1266 and 1758 kW, and the number of fans varies from 1 to 6 while the ambient temperature ranges from 30 to 50 degrees C and partial load ranges from 0.25 to 1. Results show that the partial load where the optimized COP reaches its maximum value, ranges from 0.68 to 0.76 and decreases by increasing the size of chiller A correlation is proposed for partial load at which COP reaches its maximum value, as a function of nominal cooling capacity and outdoor ambient temperature. Finally, it is found that the average amount of 5.6 GWh/year electric energy saving and 5.1 ton/year CO2 emission reduction can be achieved by optimization of number of condenser fans. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:163 / 179
页数:17
相关论文
共 48 条
[1]   Prediction of the long-term electric power demand under the influence of A/C systems [J].
Alsayegh, O. ;
Almatar, O. ;
Fairouz, F. ;
Ali, A. Al-Mulla .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2007, 221 (A1) :67-75
[2]   An experimental investigation of the energetic performances of HFO1234yf and its binary mixtures with HFC134a in a household refrigerator [J].
Aprea, C. ;
Greco, A. ;
Maiorino, A. .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2017, 76 :109-117
[3]  
Bahnfleth W.P., 2001, HEATING PIPING AIR C, V73, P41
[4]   An assessment of energy benefits of efficient household air-conditioners in Brazil [J].
Cardoso, Rafael Balbino ;
Horta Nogueira, Luiz Augusto ;
de Souza, Edson Palhares ;
Haddad, Jamil .
ENERGY EFFICIENCY, 2012, 5 (03) :433-446
[5]   Optimum setpoint of condensing temperature for air-cooled chillers [J].
Chan, KT ;
Yu, FW .
HVAC&R RESEARCH, 2004, 10 (02) :113-127
[6]   Experimental evaluation of refrigerant mass charge and ambient air temperature effects on performance of air-conditioning systems [J].
Deymi-Dashtebayaz, Mahdi ;
Farahnak, Mehdi ;
Moraffa, Mojtaba ;
Ghalami, Arash ;
Mohammadi, Nima .
HEAT AND MASS TRANSFER, 2018, 54 (03) :803-812
[7]   Thermodynamic analysis of natural gas reciprocating compressors based on real and ideal gas models [J].
Farzaneh-Gord, Mahmood ;
Niazmand, Amir ;
Deymi-Dashtebayaz, Mahdi ;
Rahbari, Hamid Reza .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 56 :186-197
[8]   Energy savings potential from improved building controls for the US commercial building sector [J].
Fernandez, Nick ;
Katipamula, Srinivas ;
Wang, Weimin ;
Xie, Yulong ;
Zhao, Mingjie .
ENERGY EFFICIENCY, 2018, 11 (02) :393-413
[9]   Designing an air-to-air heat exchanger dedicated to single room ventilation with heat recovery [J].
Gendebien, Samuel ;
Martens, Jonathan ;
Prieels, Luc ;
Lemort, Vincent .
BUILDING SIMULATION, 2018, 11 (01) :103-113
[10]   EXPERIMENTAL INVESTIGATION OF PERFORMANCE OF A RESIDENTIAL AIR-CONDITIONING SYSTEM WITH AN EVAPORATIVELY COOLED CONDENSER [J].
GOSWAMI, DY ;
MATHUR, GD ;
KULKARNI, SM .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :206-211