New approach for evaluating metal-porcelain interfacial bonding

被引:0
作者
Suansuwan, N
Swain, MV
机构
[1] Univ Sydney, Fac Dent, Dept Dent Mat Sci, Sydney, NSW 2006, Australia
[2] Univ Sydney, Fac Engn, Dept Mech & Mechatron, Sydney, NSW 2006, Australia
[3] Khon Kaen Univ, Fac Dent, Dept Prosthodont, Khon Kaen, Thailand
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to evaluate the bonding characteristics of porcelain-fused-to-metal (PFM) systems by determining the strain energy release rate associated with interface fracture of porcelain and metals. Materials and Methods: Porcelain-veneered metal plates cast from commercially pure titanium and 3 metal alloys (gold, palladium, and nickel-chromium alloys) were made to dimensions of 25 mm x 8 mm x 2.5 mm with comparable thicknesses of porcelain and metal. The porcelain side of the specimens was notched to the interface with a thin diamond saw, and a small precrack was initiated at the metal-porcelain interface, The samples were subjected to a limited number (typically less than 4) of load-unload cycles under 4-point bending at a crosshead speed of 0.1 mm/min. The loading and unloading force displacements associated with stable crack extension were recorded. The strain energy release rate was calculated. The interfacial area was also examined under scanning electron microscope (SEM) after the test. Results: The mean strain energy release rates were 72.7 +/- 10.0 J/m(2), 58.5 +/- 13.5 J/m(2), 39.4 +/- 4.3 J/m(2), and 16.6 +/- 2.5 J/m(2) for the samples of gold, palladium, nickel-chromium alloys, and titanium, respectively. The SEM photographs showed that the crack occurred in the porcelain layer close to the interface. Conclusion: The bonding characteristics of PFM systems were determined with 3 types of metal alloys and commercially pure titanium by a fracture mechanics approach. The gold alloy and titanium are considered to obtain the greatest and least adhesion, respectively. The test system has proven to be a simple and reliable approach to determine the bonding in bimaterial systems.
引用
收藏
页码:547 / 552
页数:6
相关论文
共 40 条
[1]   COMPARATIVE-EVALUATION OF CERAMIC-METAL BOND TESTS USING FINITE-ELEMENT STRESS-ANALYSIS [J].
ANUSAVICE, KJ ;
DEHOFF, PH ;
FAIRHURST, CW .
JOURNAL OF DENTAL RESEARCH, 1980, 59 (03) :608-613
[2]  
ANUSAVICE KJ, 1985, DENT CLIN N AM, V29, P789
[3]  
Brown D, 1992, Dent Update, V19, P325
[4]   EFFECTS OF SPUTTERED METAL-OXIDE FILMS ON THE CERAMIC-TO-METAL BOND [J].
BULLARD, JT ;
DILL, RE ;
MARKER, VA ;
PAYNE, EV .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 54 (06) :776-778
[5]   AN EXPERIMENTAL-STUDY OF THE FRACTURE-RESISTANCE OF BIMATERIAL INTERFACES [J].
CAO, HC ;
EVANS, AG .
MECHANICS OF MATERIALS, 1989, 7 (04) :295-304
[6]   FLEXURAL METHOD FOR EVALUATION OF METAL-CERAMIC BOND STRENGTHS [J].
CAPUTO, AA ;
DUNN, B ;
REISBICK, MH .
JOURNAL OF DENTAL RESEARCH, 1977, 56 (12) :1501-1506
[7]   Fracture energy of glass-alumina interfaces via the bimaterial bend test [J].
Cazzato, A ;
Faber, KT .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1997, 80 (01) :181-188
[8]   A test specimen for determining the fracture resistarim of bimaterial interfaces [J].
Charalambides, PG ;
Lund, J ;
Evans, AG ;
McMeeking, RM .
JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1989, 56 (01) :77-82
[9]   Evaluation of the strain energy release rate for the fracture of titanium-porcelain interfacial bonding [J].
Chung, HGP ;
Swain, MV ;
Mori, T .
BIOMATERIALS, 1997, 18 (23) :1553-1557
[10]  
CRAIG RG, 1993, RESTORATIVE DENT MAT, P491